Cristina Nuzzi

Dr. Cristina Nuzzi

Industrial and Mechanical Engineering, University of Brescia, Brescia, Lombardy, Italy
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2019 in IEEE Instrumentation & Measurement Magazine
Verified
Journal Article
Closed access
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
Simone PasinettiSimone Pasinetti
Simone Pasinetti
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
FDFranco Docchio
Franco Docchio
GSGiovanna Sansoni
Giovanna Sansoni
This paper is a first step towards a smart hand gesture recognition set up for Collaborative Robots using a Faster R-CNN Object Detector to find the accurate position of the hands in RGB images. In this work, a gesture is defined as a combination of two hands, where one is an anchor and the other codes the command for the robot. Other spatial requirements are used to improve the performances of the model and filter out the incorrect predictions made by the detector. As a first step, we used only four gestures.

1 April 2021 in Robotics and Computer-Integrated Manufacturing
Verified
Journal Article
Closed access
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
Simone PasinettiSimone Pasinetti
Simone Pasinetti
Roberto PaganiRoberto Pagani
Roberto Pagani
SGStefano Ghidini
Stefano Ghidini
MBManuel Beschi
Manuel Beschi
GSGiovanna Sansoni
Giovanna Sansoni

1 April 2021 in Data in Brief
Verified
Journal Article
Open access
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
Simone PasinettiSimone Pasinetti
Simone Pasinetti
Roberto PaganiRoberto Pagani
Roberto Pagani
GCGabriele Coffetti
Gabriele Coffetti
GSGiovanna Sansoni
Giovanna Sansoni
The HANDS dataset has been created for human-robot interaction research, and it is composed of spatially and temporally aligned RGB and Depth frames. It contains 12 static single-hand gestures performed with both the right-hand and the left-hand, and 3 static two-hands gestures for a total of 29 unique classes. Five actors (two females and three males) have been acquired performing the gestures, each of them adopting a different background and light conditions. For each actor, 150 RGB frames and their corresponding 150 Depth frames per gesture have been collected, for a total of 2400 RGB frames and 2400 Depth frames per actor.

3 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Simone PasinettiSimone Pasinetti
Simone Pasinetti
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
Alessandro LuchettiAlessandro Luchetti
Alessandro Luchetti
Matteo ZanettiMatteo Zanetti
Matteo Zanetti
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
Mariolino  De Cecco Mariolino De Cecco
Mariolino De Cecco
Time-of-flight cameras are widely adopted in a variety of indoor applications ranging from industrial object measurement to human activity recognition. However, the available products may differ in terms of the quality of the acquired point cloud, and the datasheet provided by the constructors may not be enough to guide researchers in the choice of the perfect device for their application. Hence, this work details the experimental procedure to assess time-of-flight cameras’ error sources that should be considered when designing an application involving time-of-flight technology, such as the bias correction and the temperature influence on the point cloud stability. This is the first step towards a standardization of the metrological characterization procedure that could ensure the robustness and comparability of the results among tests and different devices. The procedure was conducted on Kinect Azure, Basler Blaze 101, and Basler ToF 640 cameras. Moreover, we compared the devices in the task of 3D reconstruction following a procedure involving the measure of both an object and a human upper-body-shaped mannequin. The experiment highlighted that, despite the results of the previously conducted metrological characterization, some devices showed evident difficulties in reconstructing the target objects. Thus, we proved that performing a rigorous evaluation procedure similar to the one proposed in this paper is always necessary when choosing the right device.

13 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Simone PasinettiSimone Pasinetti
Simone Pasinetti
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
NCNicola Covre
Nicola Covre
Alessandro LuchettiAlessandro Luchetti
Alessandro Luchetti
LMLuca Maule
Luca Maule
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
This paper presents the validation of a marker-less motion capture system used to evaluate the upper limb stress of subjects using exoskeletons for locomotion. The system fuses the human skeletonization provided by commercial 3D cameras with forces exchanged by the user to the ground through upper limbs utilizing instrumented crutches. The aim is to provide a low cost, accurate, and reliable technology useful to provide the trainer a quantitative evaluation of the impact of assisted gait on the subject without the need to use an instrumented gait lab. The reaction forces at the upper limbs’ joints are measured to provide a validation focused on clinically relevant quantities for this application. The system was used simultaneously with a reference motion capture system inside a clinical gait analysis lab. An expert user performed 20 walking tests using instrumented crutches and force platforms inside the observed volume. The mechanical model was applied to data from the system and the reference motion capture, and numerical simulations were performed to assess the internal joint reaction of the subject’s upper limbs. A comparison between the two results shows a root mean square error of less than 2% of the subject’s body weight.

8 March 2021 in Robotics
Verified
Journal Article
Open access
PDF file
Roberto PaganiRoberto Pagani
Roberto Pagani
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
Marco GhidelliMarco Ghidelli
Marco Ghidelli
Alberto BorboniAlberto Borboni
Alberto Borboni
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
Giovanni LegnaniGiovanni Legnani
Giovanni Legnani
Since cobots are designed to be flexible, they are frequently repositioned to change the production line according to the needs; hence, their working area (user frame) needs to be often calibrated. Therefore, it is important to adopt a fast and intuitive user frame calibration method that allows even non-expert users to perform the procedure effectively, reducing the possible mistakes that may arise in such contexts. The aim of this work was to quantitatively assess the performance of different user frame calibration procedures in terms of accuracy, complexity, and calibration time, to allow a reliable choice of which calibration method to adopt and the number of calibration points to use, given the requirements of the specific application. This has been done by first analyzing the performances of a Rethink Robotics Sawyer robot built-in user frame calibration method (Robot Positioning System, RPS) based on the analysis of a fiducial marker distortion obtained from the image acquired by the wrist camera. This resulted in a quantitative analysis of the limitations of this approach that only computes local calibration planes, highlighting the reduction of performances observed. Hence, the analysis focused on the comparison between two traditional calibration methods involving rigid markers to determine the best number of calibration points to adopt to achieve good repeatability performances. The analysis shows that, among the three methods, the RPS one resulted in very poor repeatability performances (1.42 mm), while the three and five points calibration methods achieve lower values (0.33 mm and 0.12 mm, respectively) which are closer to the reference repeatability (0.08 mm). Moreover, comparing the overall calibration times achieved by the three methods, it is shown that, incrementing the number of calibration points to more than five, it is not suggested since it could lead to a plateau in the performances, while increasing the overall calibration time.