Marco Ghidelli

Dr. Marco Ghidelli

DSMC, University of Brescia, Brescia, Lombardy, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2021 in Robotics
Verified
Journal Article
Open access
PDF file
Roberto PaganiRoberto Pagani
Roberto Pagani
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
Marco GhidelliMarco Ghidelli
Marco Ghidelli
Alberto BorboniAlberto Borboni
Alberto Borboni
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
Giovanni LegnaniGiovanni Legnani
Giovanni Legnani
Since cobots are designed to be flexible, they are frequently repositioned to change the production line according to the needs; hence, their working area (user frame) needs to be often calibrated. Therefore, it is important to adopt a fast and intuitive user frame calibration method that allows even non-expert users to perform the procedure effectively, reducing the possible mistakes that may arise in such contexts. The aim of this work was to quantitatively assess the performance of different user frame calibration procedures in terms of accuracy, complexity, and calibration time, to allow a reliable choice of which calibration method to adopt and the number of calibration points to use, given the requirements of the specific application. This has been done by first analyzing the performances of a Rethink Robotics Sawyer robot built-in user frame calibration method (Robot Positioning System, RPS) based on the analysis of a fiducial marker distortion obtained from the image acquired by the wrist camera. This resulted in a quantitative analysis of the limitations of this approach that only computes local calibration planes, highlighting the reduction of performances observed. Hence, the analysis focused on the comparison between two traditional calibration methods involving rigid markers to determine the best number of calibration points to adopt to achieve good repeatability performances. The analysis shows that, among the three methods, the RPS one resulted in very poor repeatability performances (1.42 mm), while the three and five points calibration methods achieve lower values (0.33 mm and 0.12 mm, respectively) which are closer to the reference repeatability (0.08 mm). Moreover, comparing the overall calibration times achieved by the three methods, it is shown that, incrementing the number of calibration points to more than five, it is not suggested since it could lead to a plateau in the performances, while increasing the overall calibration time.

7 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Marco GhidelliMarco Ghidelli
Marco Ghidelli
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
Francesco CrennaFrancesco Crenna
Francesco Crenna
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
This research paper aimed to validate two methods for measuring loads during walking with instrumented crutches: one method to estimate partial weight-bearing on the lower limbs and another to estimate shoulder joint reactions. Currently, gait laboratories, instrumented with high-end measurement systems, are used to extract kinematic and kinetic data, but such facilities are expensive and not accessible to all patients. The proposed method uses instrumented crutches to measure ground reaction forces and does not require any motion capture devices or force platforms. The load on the lower limbs is estimated by subtracting the forces measured by the crutches from the subject’s total weight. Since the model does not consider inertia contribution in dynamic conditions, the estimation improves with low walking cadence when walking with the two-point contralateral and the three-point partial weight-bearing patterns considered for the validation tests. The shoulder joint reactions are estimated using linear regression, providing accurate values for the forces but less accurate torque estimates. The crutches data are acquired and processed in real-time, allowing for immediate feedback, and the system can be used outdoors in real-world walking conditions. The validation of this method could lead to better monitoring of partial weight-bearing and shoulder joint reactions, which could improve patient outcomes and reduce complications.

28 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Cristina NuzziCristina Nuzzi
Cristina Nuzzi
Marco GhidelliMarco Ghidelli
Marco Ghidelli
Alessandro LuchettiAlessandro Luchetti
Alessandro Luchetti
Matteo ZanettiMatteo Zanetti
Matteo Zanetti
Francesco CrennaFrancesco Crenna
Francesco Crenna
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
An open question for the biomechanical research community is accurate estimation of the volume and mass of each body segment of the human body, especially when indirect measurements are based on biomechanical modeling. Traditional methods involve the adoption of anthropometric tables, which describe only the average human shape, or manual measurements, which are time-consuming and depend on the operator. We propose a novel method based on the acquisition of a 3D scan of a subject’s body, which is obtained using a consumer-end RGB-D camera. The body segments’ separation is obtained by combining the body skeleton estimation of BlazePose with a biomechanical-coherent skeletal model, which is defined according to the literature. The volume of each body segment is computed using a 3D Monte Carlo procedure. Results were compared with manual measurement by experts, anthropometric tables, and a model leveraging truncated cone approximations, showing good adherence to reference data with minimal differences (ranging from +0.5 to −1.0 dm3 for the upper limbs, −0.1 to −4.2 dm3 for the thighs, and −0.4 to −2.3 dm3 for the shanks). In addition, we propose a novel indicator based on the computation of equivalent diameters for each body segment, highlighting the importance of gender-specific biomechanical models to account for the chest and pelvis areas of female subjects.

6 July 2021 in Frontiers in Neurology
Verified
Journal Article
Open access
Federica TamburellaFederica Tamburella
Federica Tamburella
MLMatteo Lorusso
Matteo Lorusso
NTNevio Luigi Tagliamonte
Nevio Luigi Tagliamonte
FBFrancesca Bentivoglio
Francesca Bentivoglio
ABAlessandra Bigioni
Alessandra Bigioni
MMMarco Molinari
Marco Molinari
Background:Crutches are the most common walking aids prescribed to improve mobility in subjects with central nervous system (CNS) lesions. To increase adherence to the appropriate level of crutch usage, providing load-related auditory feedback (aFB) may be a useful approach. We sensorized forearm crutches and developed a custom software to provide aFB information to both user and physical therapist (PhT).Aim:Evaluate aFB effects on load control during gait by a self-controlled case series trial.Methods:A single experimental session was conducted enrolling 12 CNS lesioned participants. Load on crutch was recorded during 10 Meter Walk Test performed with and without aFB. In both cases, crutch load data, and gait speed were recorded. Usability and satisfaction questionnaires were administered to participants and PhTs involved.Results:Reliable data were obtained from eight participants. Results showed that compared to the no FB condition, aFB yielded a significant reduction in the mean load on the crutches during gait (p= 0.001). The FB did not influence gait speed or fatigue (p> 0.05). The experience questionnaire data indicated a positive experience regarding the use of aFB from both participants' and PhTs' perspectives.Conclusion:aFB significantly improves compliance with crutch use and does not affect gait speed or fatigue by improving the load placed on crutches. The FB is perceived by users as helpful, safe, and easy to learn, and does not interfere with attention or concentration while walking. Furthermore, the PhTs consider the system to be useful, easy to learn and reliable.

28 December 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
EFEnrico Ferlinghetti
Enrico Ferlinghetti
ISInge Salzmann
Inge Salzmann
Marco GhidelliMarco Ghidelli
Marco Ghidelli
TRThomas Rietveld
Thomas Rietveld
Riemer JK VegterRiemer JK Vegter
Riemer JK Vegter
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
This study investigates the reliability of marker-less vision systems for contact detection between hand and hand-rim during wheelchair propulsion. The measurement system uses a camera collecting RGB and depth images. The hand is detected through Mediapipe, a software able to recognize the key points of the hand on the RGB image. Hand position is expressed with respect to the wheel. A classifier is used to determine if there is contact between hand and hand-rim. To validate this procedure, 17 able-bodied participants pushed the wheelchair on an ergometer during six tests, given by the combinations of holding a tennis racket in their right hand while propelling at three different speeds: 4 km/h, 5.4 km/h and maximal sprint. Since validated contact detection methods are lacking in literature, experts provided a reference by manually evaluating video recordings and force signals frame-by-frame. The results showed that the hand identification by Mediapipe is not influenced by the presence of the racket but by the speed. Contact events were detected in the 99.5% of the cases. The mean error in contact time detection was -5 ms for the starts and 18 ms for the ends, the standard deviation was 48 ms for both and the combined root mean square error (RMSE) was 48 ms for the starts and 50 ms for the ends. These values, once corrected the systematic effects, lead to a standard uncertainty of approximately 0.05 s, corresponding to 15 % of the average contact duration. The study highlights the potential use of marker-less vision systems for contact detection in wheelchair propulsion.

2 July 2021
Verified
Book Chapter
Closed access
PDF file
Matteo LANCINIMatteo LANCINI
Matteo LANCINI
Simone PasinettiSimone Pasinetti
Simone Pasinetti
Marco GhidelliMarco Ghidelli
Marco Ghidelli
PPPietro Padovani
Pietro Padovani
DPDavid Pinto-Fernández
David Pinto-Fernández
DTDiego Torricelli
Diego Torricelli