The healthcare-related functions of wearable devices are very useful for continuous monitoring of biological information. Wearable devices equipped with communication function can be used for additional healthcare services. Among the wearable devices, the wristband type is most suitable for acquiring biological signals, and the wear preference of the user is high, so it is highly likely to be used more in the future. In this paper, the health-related functions of wristband were investigated and the technical limitations and prospects were also reviewed. Most current wristband-type devices are equipped with the combination of accelerometer, optical sensor, and electrodes for their health functions, and continuously measured data are expanding the possibility of discovering new medical meanings. The blood pressure measurement function without using cuff is the most useful and expected function among the health-related functions expected to be mounted on the wrist wearable device, in spite of its technical limits and difficulties.
We designed and experimentally demonstrated a thin film filter (TFF)-embedded directional coupler-type triplexing-filter on the planar-lightwave-circuit platform. The triple-play multiplexing was significantly simplified by using one TFF. The 1.31- and 1.55-/spl mu/m lights were designed to be divided after passing the directional coupler by half-cycle and full-cycle coupling actions, respectively. The 1.49-/spl mu/m light was reflected by a TFF inserted in a trench on the directional coupler. The insertion losses of fabricated triplexing-filters were less than 2.0 dB with bandwidths of 20 nm. The newly proposed triplexing-filter provides a cost-effective high-performance solution for fiber-to-the-home networks.
21 October 2018 in Journal of Healthcare Engineering
According to the theoretical equation of the pulse oximeter expressed by the ratio of amplitude (AC) and baseline (DC) obtained from the photoplethysmographic signal of two wavelengths, the difference of the amount of light absorbed depending on the melanin indicating the skin color is canceled by normalizing the AC value to the DC value of each wavelength. Therefore, theoretically, skin color does not affect the accuracy of oxygen saturation measurement. However, if there is a direct path for the light emitting unit to the light receiving unit instead of passing through the human body, the amount of light reflected by the surface of the skin changes depending on the color of the skin. As a result, the amount of crosstalk that varies depending on the skin color affects the ratio of AC to DC, resulting in errors in the calculation of the oxygen saturation value. We made crosstalk sensors and crosstalk-free sensors and performed desaturation experiments with respiratory gas control on subjects with various skin colors to perform oxygen saturation measurements ranging from 60 to 100%. Experimental results showed that there was no difference in the measurement error of oxygen saturation according to skin color in the case of the sensor which prevented crosstalk (−0.8824 ± 2.2859 for Asian subjects, 0.6741 ± 3.2822 for Caucasian subjects, and 0.9669 ± 2.2268 for African American subjects). However, a sensor that did not prevent crosstalk showed a large error in dark skin subjects (0.8258 ± 2.1603 for Asian subjects, 0.8733 ± 1.9716 for Caucasian subjects, and −3.0591 ± 3.9925 for African Americans). Based on these results, we reiterate the importance of sensor design in the development of pulse oximeters using reflectance-type sensors.
We proposed and tested a method to estimate sleep period time (SPT) using electrodermal activity (EDA) signals. Eight healthy subjects and six obstructive sleep apnea patients participated in the experiments. Each subject's EDA signals were measured at the middle and ring fingers of the dominant hand during polysomnography (PSG). For nine of the 17 participants, wrist actigraphy was also measured for a quantitative comparison of EDA- and actigraphy-based methods. Based on the training data, we observed that sleep onset was accompanied by a gradual reduction of amplitude of the EDA signals, whereas sleep offset was accompanied by a rapid increase in amplitude of EDA signals. We developed a method based on these EDA fluctuations during sleep-wake transitions, and applied it to a test dataset. The performance of the method was assessed by comparing its results with those from a physician's sleep stage scores. The mean absolute errors in the obtained values for sleep onset, offset, and period time between the proposed method, and the results of the PSG were 4.1, 3.0, and 6.1 min, respectively. Furthermore, there were no significant differences in the corresponding values between the methods. We compared these results with those obtained by applying actigraphic methods, and found that our algorithm outperformed these in terms of each estimated parameter of interest in SPT estimation. Long awakening periods were also detected based on sympathetic responses reflected in the EDA signals. The proposed method can be applied to a daily sleep monitoring system.
Arterial stiffness is considered an index of vascular aging. The brachial–ankle pulse wave velocity (baPWV) method is widely used because of its proven effectiveness; and the pulse wave velocity measurement method using both electrocardiogram (ECG) and photoplethysmogram (PPG) is actively being studied due to the convenience of measurement and the possibility of miniaturization. The aim of this study was to evaluate and compare the effects of age and gender in Korean adults using both the baPWV method and the PWV method with ECG and finger PPG (heart–finger PWV). The measurements have been carried out for 185 healthy subjects of Korean adults, and the results showed that the baPWV was highly correlated with age in both genders (r = 0.94 for both males and females). However, the correlation values in heart–finger PWV measurement were significantly lower than those of baPWV (r = 0.37 for males and r = 0.71 for females). Although the heart–finger PWV method is suitable for mobile applications because it can be easily miniaturized while maintaining its signal quality, these results show that the heart–finger PWV method is not as effective as baPWV at evaluating the arterial stiffness.