Hyun Jae Baek

Prof. Hyun Jae Baek

Department of Medical and Mechatronics Engineering, Soonchunhyang University, Asan, Chungnam, Korea
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2023 in Electronics
Verified
Journal Article
Open access
PDF file
KKKwang Bok Kim
Kwang Bok Kim
HBHyun Jae Baek
Hyun Jae Baek
Photoplethysmography (PPG) is an affordable and straightforward optical technique used to detect changes in blood volume within tissue microvascular beds. PPG technology has found widespread application in commercial medical devices, enabling measurements of oxygen saturation, blood pressure, and cardiac output; the assessment of autonomic nerve function; and the diagnosis of peripheral vascular disease. Recently, the growing demand for non-invasive, portable, cost-effective technology, along with advancements in small semiconductor components, has led to the integration of PPG into various wrist-worn wearable devices. Multiple sensor structures have been proposed and, through appropriate signal processing and algorithmic application, these wearable devices can measure a range of health indicators during daily life. This paper begins by addressing the market status of wrist-worn wearable devices, followed by an explanation of the fundamental principles underlying light operation and its interaction with living tissue for PPG measurements. Moving on to technological advancements, the paper addresses the analog front end for the measurement of the PPG signal, sensor configurations with multiple light emitters and receivers, the minimum sampling rate required for low-power systems, and the measurement of stress, sleep, blood pressure, blood glucose, and activity using PPG signals. Several challenges in the field are also identified, including selecting the appropriate wavelength for the PPG sensor’s light source, developing low-power interpolation methods to extract high-resolution inter-beat intervals at a low sampling rate, and exploring the measurement of physiological phenomena using multi-wavelength PPG signals simultaneously collected at the same location. Lastly, the paper presents future research directions, which encompass the development of new, reliable parameters specific to wearable PPG devices and conducting studies in real-world scenarios, such as 24-h long-term measurements.

15 August 2017 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
HBHyun Jae Baek
Hyun Jae Baek
JSJaeWook Shin
JaeWook Shin

7 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HYHeenam Yoon
Heenam Yoon
HBHyun Jae Baek
Hyun Jae Baek
The increased demand for well-being has fueled interest in sleep. Research in technology for monitoring sleep ranges from sleep efficiency and sleep stage analysis to sleep disorder detection, centering on wearable devices such as fitness bands, and some techniques have been commercialized and are available to consumers. Recently, as interest in digital therapeutics has increased, the field of sleep engineering demands a technology that helps people obtain quality sleep that goes beyond the level of monitoring. In particular, interest in sleep aids for people with or without insomnia but who cannot fall asleep easily at night is increasing. In this review, we discuss experiments that have tested the sleep-inducing effects of various auditory stimuli currently used for sleep-inducing purposes. The auditory stimulations were divided into (1) colored noises such as white noise and pink noise, (2) autonomous sensory meridian response sounds such as natural sounds such as rain and firewood burning, sounds of whispers, or rubbing various objects with a brush, and (3) classical music or a preferred type of music. For now, the current clinical method of receiving drugs or cognitive behavioral therapy to induce sleep is expected to dominate. However, it is anticipated that devices or applications with proven ability to induce sleep clinically will begin to appear outside the hospital environment in everyday life.

16 June 2019 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
HBHyun Jae Baek
Hyun Jae Baek
MCMin Hye Chang
Min Hye Chang
JHJeong Heo
Jeong Heo
KPKwang Suk Park
Kwang Suk Park
Brain-computer interfaces (BCIs) aim to enable people to interact with the external world through an alternative, nonmuscular communication channel that uses brain signal responses to complete specific cognitive tasks. BCIs have been growing rapidly during the past few years, with most of the BCI research focusing on system performance, such as improving accuracy or information transfer rate. Despite these advances, BCI research and development is still in its infancy and requires further consideration to significantly affect human experience in most real-world environments. This paper reviews the most recent studies and findings about ergonomic issues in BCIs. We review dry electrodes that can be used to detect brain signals with high enough quality to apply in BCIs and discuss their advantages, disadvantages, and performance. Also, an overview is provided of the wide range of recent efforts to create new interface designs that do not induce fatigue or discomfort during everyday, long-term use. The basic principles of each technique are described, along with examples of current applications in BCI research. Finally, we demonstrate a user-friendly interface paradigm that uses dry capacitive electrodes that do not require any preparation procedure for EEG signal acquisition. We explore the capacitively measured steady-state visual evoked potential (SSVEP) response to an amplitude-modulated visual stimulus and the auditory steady-state response (ASSR) to an auditory stimulus modulated by familiar natural sounds to verify their availability for BCI. We report the first results of an online demonstration that adopted this ergonomic approach to evaluating BCI applications. We expect BCI to become a routine clinical, assistive, and commercial tool through advanced EEG monitoring techniques and innovative interface designs.

21 October 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
HBHyun Jae Baek
Hyun Jae Baek
JSJaeWook Shin
JaeWook Shin
JCJaegeol Cho
Jaegeol Cho
According to the theoretical equation of the pulse oximeter expressed by the ratio of amplitude (AC) and baseline (DC) obtained from the photoplethysmographic signal of two wavelengths, the difference of the amount of light absorbed depending on the melanin indicating the skin color is canceled by normalizing the AC value to the DC value of each wavelength. Therefore, theoretically, skin color does not affect the accuracy of oxygen saturation measurement. However, if there is a direct path for the light emitting unit to the light receiving unit instead of passing through the human body, the amount of light reflected by the surface of the skin changes depending on the color of the skin. As a result, the amount of crosstalk that varies depending on the skin color affects the ratio of AC to DC, resulting in errors in the calculation of the oxygen saturation value. We made crosstalk sensors and crosstalk-free sensors and performed desaturation experiments with respiratory gas control on subjects with various skin colors to perform oxygen saturation measurements ranging from 60 to 100%. Experimental results showed that there was no difference in the measurement error of oxygen saturation according to skin color in the case of the sensor which prevented crosstalk (−0.8824 ± 2.2859 for Asian subjects, 0.6741 ± 3.2822 for Caucasian subjects, and 0.9669 ± 2.2268 for African American subjects). However, a sensor that did not prevent crosstalk showed a large error in dark skin subjects (0.8258 ± 2.1603 for Asian subjects, 0.8733 ± 1.9716 for Caucasian subjects, and −3.0591 ± 3.9925 for African Americans). Based on these results, we reiterate the importance of sensor design in the development of pulse oximeters using reflectance-type sensors.

24 October 2017 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
HBHyun Jae Baek
Hyun Jae Baek
JSJaeWook Shin
JaeWook Shin
GJGunwoo Jin
Gunwoo Jin
JCJaegeol Cho
Jaegeol Cho