Ahmed Abdullah Al-katheri

Mr. Ahmed Abdullah Al-katheri

King Saud University, College of engineering, Riyadh, Ar Riyāḑ, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
AAAhmed Abdullah Al-katheri
Ahmed Abdullah Al-katheri
Essam A. Al-AmmarEssam A. Al-Ammar
Essam A. Al-Ammar
MAMajed Alotaibi
Majed Alotaibi
Wonsuk KoWonsuk Ko
Wonsuk Ko
SPSisam Park
Sisam Park
HCHyeong-Jin Choi
Hyeong-Jin Choi
The rapid revolution in the solar industry over the last several years has increased the significance of photovoltaic (PV) systems. Power photovoltaic generation systems work in various outdoor climate conditions; therefore, faults may occur within the PV arrays in the power system. Fault detection is a fundamental task needed to improve the reliability, efficiency, and safety of PV systems, and, if not detected, the cost associated with the loss of power generated from PV modules will be quite high. Moreover, maintenance staff will take more time and effort to fix undetermined faults. Due to the current-limiting nature and nonlinear output characteristics of PV arrays, fault detection is not that easy and the application of artificial intelligence is proposed for the sake of fault detection in PV systems. The idea behind this approach is to compare the faulty PV module with its accurate model (factory fingerprint) by checking every PV array’s I–V and P–V curves using the Artificial Neural Network (ANN) logarithm as a subsection of the Artificial Intelligence’s (AI) techniques. This proposed approach achieves a high performance of fault detection and gives the advantage of determining what type of fault has occurred. The results confirm that the proposed logarithm performance becomes better as the number of distinguishing points extend, providing great value to the Solar PV industry.

20 June 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
FAFaris E. Alfaris
Faris E. Alfaris
Essam A. Al-AmmarEssam A. Al-Ammar
Essam A. Al-Ammar
GGGhazi A. Ghazi
Ghazi A. Ghazi
AAAhmed Abdullah Al-katheri
Ahmed Abdullah Al-katheri
Distributed grid-connected photovoltaic (PV) generation explores several methods that produce energy at or near the point of consumption, with the aim of reducing electricity losses among transmission networks. Consequently, home on-grid PV applications have garnered increased interest from both scientific researchers and industry professionals over the last decade. Nevertheless, the growing installation of intermittent nature residential PV systems (R-PV) in low-voltage distribution networks is leading to more cautious considerations of technology limitations and PV design challenges. This conservative perspective arises from the standpoint of grid quality and security, ultimately resulting in the revocation of PV connection authorization. Hence, the design of R-PV systems should consider not only the specifications of the PV panels and load profiles but also the characteristics and requirements of the connected power grid. This project therefore seeks to enhance the design considerations of grid-connected PV systems, in order to help the end-users meet the grid codes set out by the Saudi Electricity Regulatory Authority (SERA). Since the maximum amount of generated power is essential for PV system optimization, the ratio of grid strength to maximum transmitted power was employed to ascertain the suitable capacity of the PV system, while the assessment of PV power output was utilized to specify the system size. Furthermore, a battery energy storage system (BESS) with a small size (~10% of the PV capacity) is employed to enhance the PV power quality for a dependable grid interconnection. The BESS is equipped with a versatile power controller in order to achieve the designed objectives. The obtained results show an essential advancement in terms of power quality and reliability at the customer’s connection point. Moreover, with the design assessment process, the low-voltage ride-through (LVRT) and power factor requirements can be met, in addition to the total harmonic distortion (THD) and frequency transient limitations. The proposed solution assists end-users in efficiently designing their own R-PV systems while ensuring quality and sustainability for authorized grid interconnection.

28 July 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
FAFaris E. Alfaris
Faris E. Alfaris
Essam A. Al-AmmarEssam A. Al-Ammar
Essam A. Al-Ammar
GGGhazi A. Ghazi
Ghazi A. Ghazi
AAAhmed Abdullah Al-katheri
Ahmed Abdullah Al-katheri
As a result of global efforts to combat the rise in global climate change and carbon dioxide emissions, there has been a substantial increase in renewable energy investment for both residential and utility power generation. Solar power facilities are estimated to be among the major contributors to global decarbonization in terms of capacity by 2050. Consequently, the majority of economically significant countries are progressively implementing utility-scale photovoltaic (U-PV) systems. Nevertheless, a major obstacle to the expansion of U-PV generation is the identification and assessment of direct current (DC) faults in the extensive array of PV panels. In order to address this obstacle, it is imperative to provide an evaluation method that can accurately and cost-effectively identify and locate potential DC faults in PV arrays. Therefore, many studies attempted to utilize thermal cameras, voltage and current sensors, power databases, and other detecting elements; however, some of these technologies provide extra hurdles in terms of the quantity and expense of the utilized hardware equipment. This work presents a sophisticated system that aims to diagnose and locate various types of PV faults, such as line-to-ground, line-to-line, inter-string, open-circuit, and partial shading events, within a PV array strings down to a module level. This study primarily depends on three crucial indicators: precise calculation of the PV array output power and current, optimal placement of a limited number of voltage sensors, and execution of specifically specified tests. The estimation of PV array power, along with selectively placed voltage sensors, minimizes the time and equipment required for fault detection and diagnosis. The feasibility of the proposed method is investigated with real field data and the PSCAD simulation platform during all possible weather conditions and array faults. The results demonstrate that the proposed approach can accurately diagnose and localize faults with only NS/2 voltage sensors, where NS is the number of PV array parallel strings.