In building areas with high occupancy, such as classrooms, transmission routes of SARS-CoV-2 are increased when indoor air quality is deficient. Under this scenario, universities have adopted ventilation measures to mitigate contagious environments. However, the lack of adequate equipment or designs in old educational buildings is a barrier to reach minimum requirements. This study aims to quantify the indoor air quality and thermal comfort at universities and compare it to conditions in students’ households. In this regard, several classrooms in buildings of the Polytechnic University of Catalonia were monitored for temperature, CO2 concentration and relative humidity. The people who used these classrooms were surveyed about their comfort perceptions. A sample of students was also monitored at their homes where they reported to studying during the exam period. By means of point-in-time surveys, students reported their daily comfort, for comparison with the monitored data. The results show that the recommendations for CO2 concentration, temperature, and relative humidity are not always met in any of the study spaces. These factors are more critical at universities due to the high occupancy. In addition, the surveys highlighted the perception that the environment is better at home than at university.
The COVID‐19 emergency evidenced the value of keeping indoor spaces properly ventilated, which increased the interest in CO 2 loggers. However, when monitoring, many significant variables are often overlooked, such as sensor specifications, the position of the system with respect to the airflow path (or occupants), and the relationship between these variables and the ventilation system of the room. With the purpose of properly standardizing future indoor air quality measurements in classroom settings, this study evaluated the results of a measurement campaign consisting of 33 individual measurements performed on site during 5 months in primary schools and university classrooms. This work uses d CO 2 / dt to identify CO 2 tendencies while taking into account classroom topology and ventilation. Results show that variables such as their position and the ventilation strategy of the room often outweigh the sensor specifications, causing spatial discrepancies beyond 100 ppm. Along with the results, recommendations for future measurements are discussed in order to avoid nonrepresentative estimations of the CO 2 level of indoor spaces.
29 December 2023 in Journal of Building Engineering
Although optimization tools have been widely used to both minimize and control the energy consumption of buildings maintaining thermal comfort, the dramatic impact of the COVID-19 pandemic showed the relevance of considering the indoor air quality to act on the ventilation system. However, CO2 concentrations in closed environments with high occupancy rates, such as classrooms in schools, universities, or other educational environments, increase rapidly without effective ventilation, reaching the safe limits in about 15–30 min. Observing that the natural ventilation guides indicated by governments were insufficient to keep safe and comfortable spaces simultaneously, this study analyzes how mechanical heating, cooling, and ventilation systems would improve these results by using optimized control strategies in the same buildings that now use natural ventilation. Setting the objective function to minimize energy consumption, this study optimizes the use of mechanical systems considering the indoor temperature and CO2 concentration of educational indoor spaces in 4 types of schools and 3 climate zones in winter and summer. Results show that, at full occupancy, the ventilation should activate every 12 min, making slow-frequency control strategies inappropriate to keep the spaces safe. A 1-min step modeling asks for high computation that makes it critical for real-time control strategies, however, it allows a perfect setting of the working limits for legacy conditional equipment for establishing control policies on a one-day horizon.