Aya Mutaz Zeidan

Dr. Aya Mutaz Zeidan

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
WWWeizhao Wang
Weizhao Wang
ZWZicong Wu
Zicong Wu
CSCarlo Saija
Carlo Saija
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
ZXZhouyang Xu
Zhouyang Xu
James HousdenJames Housden
James Housden
Catheters have been widely used to deal with heart valve diseases. However, the diversity in handle structures and bending curvatures imposes significant complexities in safe delivery and positioning. In this letter, we designed a module for single knob actuation assembled coaxially on the catheter handle, composed of a chuck for universal clamping of diameters from 15 to 45 mm and a position-adjustable shaft to accommodate various spacing between knobs. In addition, we proposed a two-curvature with pseudo joints (TC-PJ) model for bending control of bendable sections (BSs) in catheters. The verification was decoupled into two steps based on the other three deformation patterns. Firstly, comparing the two-curvature (TC) model with pseudo-rigid-body (PRB), constant curvature (CC), and Euler spiral (ES) models to simulate planar bending and elongation, the results showed a more accurate shape representation. Then, five distinct catheters were employed to test the clamping universality of the module and tip positioning precision of the TC-PJ model which took torsion and shear strain into consideration. The root-mean-square error (RMSE) and the standard deviation (SD) of tip position and direction were analysed. Results indicated the module's suitability for clamping these catheters, with the large guide sheath exhibiting minimal position RMSE (SD) of around 0.10 (0.051) mm and 0.049 (2.15) degrees, while the puncture catheter demonstrated the highest position and direction RMSE (SD) extending to about 1.16 (0.53) mm and 0.70 (31.33) degrees, primarily attributed to the coupling of two sequential bendable components. Overall, the proposed actuation module and kinematic model showed the ability of universal manipulation and an average tip position and direction RMSE of 0.65 mm and 0.23 degrees in free space.

10 September 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
WWWeizhao Wang
Weizhao Wang
ZXZhouyang Xu
Zhouyang Xu
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
CSCarlo Saija
Carlo Saija
YZYixuan ZHENG
Yixuan ZHENG
Kawal RhodeKawal Rhode
Kawal Rhode
Accurate clip positioning (including position, direction, and orientation) in transcatheter mitral edge-to-edge repair (M-TEER) is challenging due to the complexity of manipulating tendon-driven concentric catheters under imaging guidance. Existing methods are limited to either task-space position/shape control or image-space joint control. This study presents a compact eight-DoF robot for controlling the PASCAL device, achieving closed-loop pose control in image space. Building on a prior variable curvature model, we develop a kinematic model that accounts for coupling between catheter handles and compensates for tip length variation. A prior sheath shape model is also integrated to support safer navigation in confined anatomy during clip adjustment. To achieve precise image-space pose control, we design a novel framework featuring a mapping strategy for independent control of clip position, direction, and orientation relative to registered imaging views, along with a Jacobian-based PID controller. Simulation results demonstrate effective independent control, with only direction adjustments exhibiting minor coupling with orientation (maximum deviation: 2.69$^{\circ }$). Experiments show that closed-loop control effectively mitigates catheter misalignment and rubber deformation, achieving average positional and angular RMSEs to 0.52 mm and 0.61$^{\circ }$. This robot provides precise, image-space pose control, which is expected to assist with the challenge of accurate clip positioning in M-TEER.

21 March 2025 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
WWWeizhao Wang
Weizhao Wang
CSCarlo Saija
Carlo Saija
ZXZhouyang Xu
Zhouyang Xu
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
JWJoshua Wilcox
Joshua Wilcox
James HousdenJames Housden
James Housden
Objective: This study aimed to develop and evaluate a 3-degree-of-freedom (DoF) robotic system for the safe delivery of cardiac sheaths through challenging anatomical structures, including the fossa ovalis and pathways with tight curves. Methods: The robot and its kinematic model were built on a previously proposed single-DoF actuation module and bending model. A sheath delivery strategy (SDS) was developed, combining two control methods: tip position control to approach an optimal entry point and point-constrained control to maintain consistent navigation through this point, minimizing tissue contact. Technical performance was evaluated through trajectory-following and point-crossing tests, followed by feasibility experiments in a simulated scenario. Trials were conducted by three cardiologists using a validated phantom model under fluoroscopic guidance, comparing SDS with joint control (JC) and manual control (MC). Results: Average root mean square errors were 2.10 mm for tip position control and 1.86 mm for point-constrained control. SDS outperformed MC with significantly shorter trajectory lengths and lower root mean square jerk. Compared to JC, SDS reduced sheath-induced movements (an indirect measure of force) and increased retraction success rates at the fossa ovalis. Conclusion: The proposed robotic system reduced tissue wall contact compared to JC and provided smoother, more controlled operations than MC, ensuring safer and more effective delivery through confined pathways. Significance: This work contributes to advancing robotic-assisted cardiac sheath delivery, providing a reliable and safer method for navigating challenging anatomical structures.

30 October 2024 in 3D Printing in Medicine
Verified
Journal Article
Open access
PDF file
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
ZXZhouyang Xu
Zhouyang Xu
LLLisa Leung
Lisa Leung
CBCalum Byrne
Calum Byrne
SSSachin Sabu
Sachin Sabu
KRKawal Rhode
Kawal Rhode
Background: Transseptal puncture (TSP) is a critical prerequisite for left-sided cardiac interventions, such as atrial fibrillation (AF) ablation and left atrial appendage closure. Despite its routine nature, TSP can be technically demanding and carries a risk of complications. This study presents a novel, patient-specific, anthropomorphic phantom for TSP simulation training that can be used with X-ray fluoroscopy and ultrasound imaging. Methods: The TSP phantom was developed using additive manufacturing techniques and features a replaceable fossa ovalis (FO) component to allow for multiple punctures without replacing the entire model. Four cardiologists and one cardiology trainee performed TSP on the simulator, and their performance was assessed using four metrics: global isotropy index, distance from the centroid, time taken to perform TSP, and a set of 5-point Likert scale questions to evaluate the clinicians’ perception of the phantom’s realism and utility. Results: The results demonstrate the simulator’s potential as a training tool for interventional cardiology, providing a realistic and controllable environment for clinicians to refine their TSP skills. Experienced cardiologists tended to cluster their puncture points closer to regions of the FO associated with higher global isotropy index scores, indicating a relationship between experience and optimal puncture localization. The questionnaire analysis revealed that participants generally agreed on the phantom’s realistic anatomical representation and ability to accurately visualize the TSP site under fluoroscopic guidance. Conclusions: The TSP simulator can be incorporated into training programs, offering trainees the opportunity to improve tool handling, spatial coordination, and manual dexterity prior to performing the procedure on patients. Further studies with larger sample sizes and longitudinal assessments are needed to establish the simulator’s impact on TSP performance and patient outcomes.

19 May 2024 in Robotics
Verified
Journal Article
Open access
PDF file
ZXZhouyang Xu
Zhouyang Xu
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
Yetao HeYetao He
Yetao He
LLLisa Leung
Lisa Leung
CBCalum J Byrne
Calum J Byrne
Kawal RhodeKawal Rhode
Kawal Rhode
Atrial fibrillation, the most prevalent cardiac arrhythmia, is treated by catheter ablation to isolate electrical triggers. Clinical trials on robotic catheter systems hold promise for improving the safety and efficacy of the procedure. However, expense and proprietary designs hinder accessibility to such systems. This paper details an open-source, modular, three-degree-of-freedom robotic platform for teleoperating commercial ablation catheters through joystick navigation. We also demonstrate a catheter-agnostic handle interface permitting customization with commercial catheters. Collaborating clinicians performed benchtop targeting trials, comparing manual and robotic catheter navigation performance. The robot reduced task duration by 1.59 s across participants and five trials. Validation through mean motion jerk analysis revealed 35.2% smoother robotic navigation for experts (≥10 years experience) compared to the intermediate group. Yet, both groups achieved smoother robot motion relative to the manual approach, with the experts and intermediates exhibiting 42.2% and 13.6% improvements, respectively. These results highlight the potential of this system for enhancing catheter-based procedures. The source code and designs of CardioXplorer have been made publicly available to lower boundaries and drive innovations that enhance procedure efficacy beyond human capabilities.

10 January 2023 in Machine Learning for Biomedical Imaging
Verified
Journal Article
Open access
PDF file
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
PGPaula Ramirez Gilliland
Paula Ramirez Gilliland
APAshay Patel
Ashay Patel
ZOZhanchong Ou
Zhanchong Ou
DFDimitra Flouri
Dimitra Flouri
AMAndrew Melbourne
Andrew Melbourne
Fetal growth restriction (FGR) is a prevalent pregnancy condition characterised by failure of the fetus to reach its genetically predetermined growth potential. The multiple aetiologies, coupled with the risk of fetal complications - encompassing neurodevelopmental delay, neonatal morbidity, and stillbirth - motivate the need to improve holistic assessment of the FGR fetus using MRI. We hypothesised that the fetal liver and placenta would provide insights into FGR biomarkers, unattainable through conventional methods. Therefore, we explore the application of model fitting techniques, linear regression machine learning models, deep learning regression, and Haralick textured features from multi-contrast MRI for multi-fetal organ analysis of FGR. We employed T2 relaxometry and diffusion-weighted MRI datasets (using a combined T2-diffusion scan) for 12 normally grown and 12 FGR gestational age (GA) matched pregnancies (Estimated Fetal Weight below 3rd centile, Median 28+/-3wks). We applied the Intravoxel Incoherent Motion Model, which describes circulatory properties of the fetal organs, and analysed the resulting features distinguishing both cohorts. We additionally used novel multi-compartment models for MRI fetal analysis, which exhibit potential to provide a multi-organ FGR assessment, overcoming the limitations of empirical indicators - such as abnormal artery Doppler findings - to evaluate placental dysfunction. The placenta and fetal liver presented key differentiators between FGR and normal controls, with significant decreased perfusion, abnormal fetal blood motion and reduced fetal blood oxygenation. This may be associated with the preferential shunting of the fetal blood towards the fetal brain, affecting supply to the liver. These features were further explored to determine their role in assessing FGR severity, by employing simple machine learning models to predict FGR diagnosis (100% accuracy in test data, n=5), GA at delivery, time from MRI scan to delivery, and baby weight. We additionally explored the use of deep learning to regress the latter three variables, training a convolutional neural network with our liver and placenta voxel-level parameter maps, obtained from our multi-compartment model fitting. Image texture analysis of the fetal organs demonstrated prominent textural variations in the placental perfusion fractions maps between the groups (p<0.0009), and spatial differences in the incoherent fetal capillary blood motion in the liver (p<0.009). This research serves as a proof-of-concept, investigating the effect of FGR on fetal organs, measuring differences in perfusion and oxygenation within the placenta and fetal liver, and their prognostic importance in automated diagnosis using simple machine learning models.