Zhouyang Xu

Mr. Zhouyang Xu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
WWWeizhao Wang
Weizhao Wang
ZWZicong Wu
Zicong Wu
CSCarlo Saija
Carlo Saija
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
ZXZhouyang Xu
Zhouyang Xu
James HousdenJames Housden
James Housden
Catheters have been widely used to deal with heart valve diseases. However, the diversity in handle structures and bending curvatures imposes significant complexities in safe delivery and positioning. In this letter, we designed a module for single knob actuation assembled coaxially on the catheter handle, composed of a chuck for universal clamping of diameters from 15 to 45 mm and a position-adjustable shaft to accommodate various spacing between knobs. In addition, we proposed a two-curvature with pseudo joints (TC-PJ) model for bending control of bendable sections (BSs) in catheters. The verification was decoupled into two steps based on the other three deformation patterns. Firstly, comparing the two-curvature (TC) model with pseudo-rigid-body (PRB), constant curvature (CC), and Euler spiral (ES) models to simulate planar bending and elongation, the results showed a more accurate shape representation. Then, five distinct catheters were employed to test the clamping universality of the module and tip positioning precision of the TC-PJ model which took torsion and shear strain into consideration. The root-mean-square error (RMSE) and the standard deviation (SD) of tip position and direction were analysed. Results indicated the module's suitability for clamping these catheters, with the large guide sheath exhibiting minimal position RMSE (SD) of around 0.10 (0.051) mm and 0.049 (2.15) degrees, while the puncture catheter demonstrated the highest position and direction RMSE (SD) extending to about 1.16 (0.53) mm and 0.70 (31.33) degrees, primarily attributed to the coupling of two sequential bendable components. Overall, the proposed actuation module and kinematic model showed the ability of universal manipulation and an average tip position and direction RMSE of 0.65 mm and 0.23 degrees in free space.

15 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YZYixuan ZHENG
Yixuan ZHENG
HNHongyuan Ning
Hongyuan Ning
EREason Rangarajan
Eason Rangarajan
AMAban Merali
Aban Merali
AGAdam Geale
Adam Geale
James HousdenJames Housden
James Housden
Ultrasound imaging is widely valued for its safety, non-invasiveness, and real-time capabilities but is often limited by operator variability, affecting image quality and reproducibility. Robot-assisted ultrasound may provide a solution by delivering more consistent, precise, and faster scans, potentially reducing human error and healthcare costs. Effective force control is crucial in robotic ultrasound scanning to ensure consistent image quality and patient safety. However, existing robotic ultrasound systems rely heavily on expensive commercial force sensors or the integrated sensors of commercial robotic arms, limiting their accessibility. To address these challenges, we developed a cost-effective, lightweight, 3D-printed force sensor and a hybrid position–force control strategy tailored for robotic ultrasound scanning. The system integrates patient-to-robot registration, automated scanning path planning, and multi-sensor data fusion, allowing the robot to autonomously locate the patient, target the region of interest, and maintain optimal contact force during scanning. Validation was conducted using an ultrasound-compatible abdominal aortic aneurysm (AAA) phantom created from patient CT data and healthy volunteer testing. For the volunteer testing, during a 1-min scan, 65% of the forces were within the good image range. Both volunteers reported no discomfort or pain during the whole procedure. These results demonstrate the potential of the system to provide safe, precise, and autonomous robotic ultrasound imaging in real-world conditions.

10 September 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
WWWeizhao Wang
Weizhao Wang
ZXZhouyang Xu
Zhouyang Xu
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
CSCarlo Saija
Carlo Saija
YZYixuan ZHENG
Yixuan ZHENG
Kawal RhodeKawal Rhode
Kawal Rhode
Accurate clip positioning (including position, direction, and orientation) in transcatheter mitral edge-to-edge repair (M-TEER) is challenging due to the complexity of manipulating tendon-driven concentric catheters under imaging guidance. Existing methods are limited to either task-space position/shape control or image-space joint control. This study presents a compact eight-DoF robot for controlling the PASCAL device, achieving closed-loop pose control in image space. Building on a prior variable curvature model, we develop a kinematic model that accounts for coupling between catheter handles and compensates for tip length variation. A prior sheath shape model is also integrated to support safer navigation in confined anatomy during clip adjustment. To achieve precise image-space pose control, we design a novel framework featuring a mapping strategy for independent control of clip position, direction, and orientation relative to registered imaging views, along with a Jacobian-based PID controller. Simulation results demonstrate effective independent control, with only direction adjustments exhibiting minor coupling with orientation (maximum deviation: 2.69$^{\circ }$). Experiments show that closed-loop control effectively mitigates catheter misalignment and rubber deformation, achieving average positional and angular RMSEs to 0.52 mm and 0.61$^{\circ }$. This robot provides precise, image-space pose control, which is expected to assist with the challenge of accurate clip positioning in M-TEER.

28 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SWShu Wang
Shu Wang
CSCarlo Saija
Carlo Saija
JCJustin Jin Wai Choo
Justin Jin Wai Choo
ZOZhanchong Ou
Zhanchong Ou
MBMaria Birsoan
Maria Birsoan
Kawal RhodeKawal Rhode
Kawal Rhode
Radiofrequency ablation (RFA) is a treatment used in the management of various arrhythmias including atrial fibrillation. Enhanced training for electrophysiologists through the use of physical simulators has a significant role in improving patient outcomes. The requirements for a high-fidelity simulator for cardiac RFA are challenging and not fully met by any research or commercial simulator at present. In this study, we have produced and evaluated a 3D-printed, bi-atrial model contained in a custom-made enclosure for RFA simulation using a new soft tissue-mimicking polymer, Layfomm-40, combined with thermochromic pigment and barium sulphate in an acrylic paint carrier. We evaluated the conductive properties of Layfomm-40, its sensitivity to RFA, and its visibility in X-ray imaging, and carried a full simulation of RFA in the cardiac catheterization laboratory by an electrophysiologist. We demonstrated that a patient-specific 3D-printed Layfomm-40 bi-atrial model coated with a custom thermochromic/barium sulphate paint was compatible with the CARTO3 electroanatomic mapping system and could be effectively imaged using X-ray fluoroscopy. We demonstrated the effective delivery and visualization of radiofrequency ablation lesions in this model. The simulator meets nearly all the requirements for high-fidelity physical simulation of RFA. The use of such simulators is likely to have impact on the training of electrophysiologists and the evaluation of novel RFA devices.

21 March 2025 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
WWWeizhao Wang
Weizhao Wang
CSCarlo Saija
Carlo Saija
ZXZhouyang Xu
Zhouyang Xu
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
JWJoshua Wilcox
Joshua Wilcox
James HousdenJames Housden
James Housden
Objective: This study aimed to develop and evaluate a 3-degree-of-freedom (DoF) robotic system for the safe delivery of cardiac sheaths through challenging anatomical structures, including the fossa ovalis and pathways with tight curves. Methods: The robot and its kinematic model were built on a previously proposed single-DoF actuation module and bending model. A sheath delivery strategy (SDS) was developed, combining two control methods: tip position control to approach an optimal entry point and point-constrained control to maintain consistent navigation through this point, minimizing tissue contact. Technical performance was evaluated through trajectory-following and point-crossing tests, followed by feasibility experiments in a simulated scenario. Trials were conducted by three cardiologists using a validated phantom model under fluoroscopic guidance, comparing SDS with joint control (JC) and manual control (MC). Results: Average root mean square errors were 2.10 mm for tip position control and 1.86 mm for point-constrained control. SDS outperformed MC with significantly shorter trajectory lengths and lower root mean square jerk. Compared to JC, SDS reduced sheath-induced movements (an indirect measure of force) and increased retraction success rates at the fossa ovalis. Conclusion: The proposed robotic system reduced tissue wall contact compared to JC and provided smoother, more controlled operations than MC, ensuring safer and more effective delivery through confined pathways. Significance: This work contributes to advancing robotic-assisted cardiac sheath delivery, providing a reliable and safer method for navigating challenging anatomical structures.

19 May 2024 in Robotics
Verified
Journal Article
Open access
PDF file
ZXZhouyang Xu
Zhouyang Xu
Aya Mutaz ZeidanAya Mutaz Zeidan
Aya Mutaz Zeidan
Yetao HeYetao He
Yetao He
LLLisa Leung
Lisa Leung
CBCalum J Byrne
Calum J Byrne
Kawal RhodeKawal Rhode
Kawal Rhode
Atrial fibrillation, the most prevalent cardiac arrhythmia, is treated by catheter ablation to isolate electrical triggers. Clinical trials on robotic catheter systems hold promise for improving the safety and efficacy of the procedure. However, expense and proprietary designs hinder accessibility to such systems. This paper details an open-source, modular, three-degree-of-freedom robotic platform for teleoperating commercial ablation catheters through joystick navigation. We also demonstrate a catheter-agnostic handle interface permitting customization with commercial catheters. Collaborating clinicians performed benchtop targeting trials, comparing manual and robotic catheter navigation performance. The robot reduced task duration by 1.59 s across participants and five trials. Validation through mean motion jerk analysis revealed 35.2% smoother robotic navigation for experts (≥10 years experience) compared to the intermediate group. Yet, both groups achieved smoother robot motion relative to the manual approach, with the experts and intermediates exhibiting 42.2% and 13.6% improvements, respectively. These results highlight the potential of this system for enhancing catheter-based procedures. The source code and designs of CardioXplorer have been made publicly available to lower boundaries and drive innovations that enhance procedure efficacy beyond human capabilities.