Jose Manuel Mendoza-Rangel

Dr. Jose Manuel Mendoza-Rangel

Facultad de Ingeniería Civil, Universidad Autónoma de Nuevo León, San Nicolás de los Garza, Nuevo León, Mexico
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
David M. BastidasDavid M. Bastidas
David M. Bastidas
GSGriselda Santiago-Hurtado
Griselda Santiago-Hurtado
JMJose Manuel Mendoza-Rangel
Jose Manuel Mendoza-Rangel
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
The use of supplementary cementitious materials such as fly ash, slag, and silica fume improve reinforced concrete corrosion performance, while decreasing cost and reducing environmental impact compared to ordinary Portland cement. In this study, the corrosion behavior of AISI 1018 carbon steel (CS) and AISI 304 stainless steel (SS) reinforcements was studied for 365 days. Three different concrete mixtures were tested: 100% CPC (composite Portland cement), 80% CPC and 20% silica fume (SF), and 80% CPC and 20% fly ash (FA). The concrete mixtures were designed according to the ACI 211.1 standard. The reinforced concrete specimens were immersed in a 3.5 wt.% NaCl test solution to simulate a marine environment. Corrosion monitoring was evaluated using the corrosion potential (Ecorr) according to ASTM C876 and the linear polarization resistance (LPR) according to ASTM G59. The results show that AISI 304 SS reinforcements yielded the best corrosion behavior, with Ecorr values mainly pertaining to the region of 10% probability of corrosion, and corrosion current density (icorr) values indicating passivity after 105 days of experimentation and low probability of corrosion for the remainder of the test period.

29 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
ALAbigail Landa-Sánchez
Abigail Landa-Sánchez
JGJuan Bosch Giner
Juan Bosch Giner
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
RCRene Croche
Rene Croche
LLLaura Landa-Ruiz
Laura Landa-Ruiz
David M. BastidasDavid M. Bastidas
David M. Bastidas
Novel green concrete (GC) admixtures containing 50% and 100% recycled coarse aggregate (RCA) were manufactured according to the ACI 211.1 standard. The GC samples were reinforced with AISI 1080 carbon steel and AISI 304 stainless steel. Concrete samples were exposed to 3.5 wt.% Na2SO4 and control (DI-water) solutions. Electrochemical testing was assessed by corrosion potential (Ecorr) according to the ASTM C-876-15 standard and a linear polarization resistance (LPR) technique following ASTM G59-14. The compressive strength of the fully substituted GC decreased 51.5% compared to the control sample. Improved corrosion behavior was found for the specimens reinforced with AISI 304 SS; the corrosion current density (icorr) values of the fully substituted GC were found to be 0.01894 µA/cm2 after Day 364, a value associated with negligible corrosion. The 50% RCA specimen shows good corrosion behavior as well as a reduction in environmental impact. Although having lower mechanical properties, a less dense concrete matrix and high permeability, RCA green concrete presents an improved corrosion behavior thus being a promising approach to the higher pollutant conventional aggregates.

24 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
HFHilda Amalia Ariza Figueroa
Hilda Amalia Ariza Figueroa
JGJuan Bosch Giner
Juan Bosch Giner
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
RCRene Croche
Rene Croche
GSGriselda Santiago-Hurtado
Griselda Santiago-Hurtado
David M. BastidasDavid M. Bastidas
David M. Bastidas
In this study, ternary ecological concrete (TEC) mixtures were produced with partial substitution of the ordinary Portland cement (OPC) by 10%, 20%, and 30% of sugar cane bagasse ash (SCBA) and silica fume (SF); a control mixture (100% OPC) was prepared according to ACI 211.1 standard. The studied TEC specimens were reinforced with AISI 304 stainless steel and AISI 1018 carbon steel rebars. TEC reinforced specimens were immersed in two different electrolytes, a control (DI-water) and 3.5 wt.% MgSO4 solution, for 180 days. The electrochemical corrosion was monitored by corrosion potential (Ecorr) according to ASTM C-876-15 standard, and the linear polarization resistance (LPR) technique using ASTM G59 standard. The Ecorr and current density icorr results show that AISI 304 stainless steel rebars have a high corrosion resistance, with icorr values below 0.1 µA/cm2, which is interpreted as a level of negligible corrosion. The best corrosion performance was found for the TEC mixture made with a 20% addition of blend of sugar cane bagasse ash-silica fume (SCBA-SF) to the OPC.

24 August 2021 in Crystals
Verified
Journal Article
Open access
PDF file
LLLaura Landa-Ruiz
Laura Landa-Ruiz
ALAldo Landa-Gómez
Aldo Landa-Gómez
JMJose Manuel Mendoza-Rangel
Jose Manuel Mendoza-Rangel
ALAbigail Landa-Sánchez
Abigail Landa-Sánchez
HFHilda Amalia Ariza Figueroa
Hilda Amalia Ariza Figueroa
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
In the present investigation, the physical, mechanical and durability properties of six concrete mixtures were evaluated, one of conventional concrete (CC) with 100% Portland cement (PC) and five mixtures of Ecofriendly Ternary Concrete (ETC) made with partial replacement of Portland Cement by combinations of sugar cane bagasse ash (SCBA) and silica fume (SF) at percentages of 10, 20, 30, 40 and 50%. The physical properties of slump, temperature, and unit weight were determined, as well as compressive strength, rebound number, and electrical resistivity as a durability parameter. All tests were carried out according to the ASTM and ONNCCE standards. The obtained results show that the physical properties of ETC concretes are very similar to those of conventional concrete, complying with the corresponding regulations. Compressive strength results of all ETC mixtures showed favorable performances, increasing with aging, presenting values similar to CC at 90 days and greater values at 180 days in the ETC-20 and ETC-30 mixtures. Electrical resistivity results indicated that the five ETC mixtures performed better than conventional concrete throughout the entire monitoring period, increasing in durability almost proportionally to the percentage of substitution of Portland cement by the SCBA–SF combination; the ETC mixture made with 40% replacement had the highest resistivity value, which represents the longest durability. The present electrical resistivity indicates that the durability of the five ETC concretes was greater than conventional concrete. The results show that it is feasible to use ETC, because it meets the standards of quality, mechanical resistance and durability, and offers a very significant and beneficial contribution to the environment due to the use of agro-industrial and industrial waste as partial substitutes up to 50% of CPC, which contributes to reduction in CO2 emissions due to the production of Portland cement, responsible for 8% of total emissions worldwide.

28 March 2022 in Construction and Building Materials
Verified
Journal Article
Closed access
JGJ.V. González-Aviña
J.V. González-Aviña
CJC.A. Juárez-Alvarado
C.A. Juárez-Alvarado
BTBernardo T. Terán-Torres
Bernardo T. Terán-Torres
JMJose Manuel Mendoza-Rangel
Jose Manuel Mendoza-Rangel
ADA. Durán-Herrera
A. Durán-Herrera
JRjose antonio rodriguez rodriguez
jose antonio rodriguez rodriguez

28 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LLLaura Landa-Ruiz
Laura Landa-Ruiz
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
JGJuan Bosch Giner
Juan Bosch Giner
JRJacob Ress
Jacob Ress
GSGriselda Santiago-Hurtado
Griselda Santiago-Hurtado
David M. BastidasDavid M. Bastidas
David M. Bastidas
This research evaluates the behavior corrosion of galvanized steel (GS) and AISI 1018 carbon steel (CS) embedded in conventional concrete (CC) made with 100% CPC 30R and two binary sustainable concretes (BSC1 and BSC2) made with sugar cane bagasse ash (SCBA) and silica fume (SF), respectively, after 300 days of exposure to 3.5 wt.% MgSO4 solution as aggressive medium. Electrochemical techniques were applied to monitor corrosion potential (Ecorr) according to ASTM C-876-15 and linear polarization resistance (LPR) according to ASTM G59 for determining corrosion current density (icorr). Ecorr and icorr results indicate after more than 300 days of exposure to the sulfate environment (3.5 wt.% MgSO4 solution), that the CS specimens embedded in BSC1 and BSC2 presented greater protection against corrosion in 3.5 wt.% MgSO4 than the specimens embedded in CC. It was also shown that this protection against sulfates is significantly increased when using GS reinforcements. The results indicate a higher resistance to corrosion by exposure to 3.5 wt.% magnesium sulfate two times greater for BSC1 and BSC2 specimens reinforced with GS than the specimens embedding CS. In summary, the combination of binary sustainable concrete with galvanized steel improves durability and lifetime in service, in addition to reducing the environmental impact of the civil engineering structures.