Miguel  Angel Baltazar-Zamora

Dr. Miguel Angel Baltazar-Zamora

Full-time Research Professor of the Faculty of Civil Engineering - Xalapa, Universidad Veracruzana
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
David M. BastidasDavid M. Bastidas
David M. Bastidas
GSGriselda Santiago-Hurtado
Griselda Santiago-Hurtado
JMJose Manuel Mendoza-Rangel
Jose Manuel Mendoza-Rangel
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
The use of supplementary cementitious materials such as fly ash, slag, and silica fume improve reinforced concrete corrosion performance, while decreasing cost and reducing environmental impact compared to ordinary Portland cement. In this study, the corrosion behavior of AISI 1018 carbon steel (CS) and AISI 304 stainless steel (SS) reinforcements was studied for 365 days. Three different concrete mixtures were tested: 100% CPC (composite Portland cement), 80% CPC and 20% silica fume (SF), and 80% CPC and 20% fly ash (FA). The concrete mixtures were designed according to the ACI 211.1 standard. The reinforced concrete specimens were immersed in a 3.5 wt.% NaCl test solution to simulate a marine environment. Corrosion monitoring was evaluated using the corrosion potential (Ecorr) according to ASTM C876 and the linear polarization resistance (LPR) according to ASTM G59. The results show that AISI 304 SS reinforcements yielded the best corrosion behavior, with Ecorr values mainly pertaining to the region of 10% probability of corrosion, and corrosion current density (icorr) values indicating passivity after 105 days of experimentation and low probability of corrosion for the remainder of the test period.

24 April 2023 in Metals
Verified
Journal Article
Open access
PDF file
Jose Miguel Villegas TovarJose Miguel Villegas Tovar
Jose Miguel Villegas Tovar
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
MLMaria Del Refugio Lara-Banda
Maria Del Refugio Lara-Banda
EMErick Maldonado-Bandala
Erick Maldonado-Bandala
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
Precipitation-hardening (PH) stainless steels (SS) are widely used in various aerospace applications. These steels exhibit good mechanical and corrosion resistance. The electrochemical behavior of 15-5PH, 17-4PH, Custom450 and AM 350 stainless steels passivated with citric and nitric acid baths for 60 and 90 min at 25 and 49 °C were evaluated in 5 wt.% sodium chloride (NaCl) and 1 wt.% sulfuric acid (H2SO4) solutions. The electrochemical behavior was studied with potentiodynamic polarization curves (PPC) according to the ASTM G5-13 standard. The results indicated that there are two characteristic mechanisms that are present in the potentiodynamic polarization curves. When the PHSS is immersed in an H2SO4 solution, there is a secondary passivation, and in the NaCl solution, there is a pseudo-passivation (not stable passivation film). The current densities in the NaCl solution were between 10−4 and 10−5 mA/cm2, while those of H2SO4 were recorded around 10−2 and 10−3 mA/cm2. Citric acid does work as a passivating solution, and in some cases, the corrosion resistance of the stainless steel was comparable to that of nitric acid.

29 May 2020 in Coatings
Verified
Journal Article
Open access
PDF file
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
MMMarvin Montoya-Rangel
Marvin Montoya-Rangel
José Cabral MiramontesJosé Cabral Miramontes
José Cabral Miramontes
Francisco Humberto Estupinan-LopezFrancisco Humberto Estupinan-Lopez
Francisco Humberto Estupinan-Lopez
Patricia Zambrano-RobledoPatricia Zambrano-Robledo
Patricia Zambrano-Robledo
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
AlCrN/TiSi, AlCrN/TiCrSiN and AlCrN/AlCrN + CrN coatings were deposited on Inconel 718 alloy by physical vapour deposition (PVD). The corrosion behaviour of uncoated and coated specimens was evaluated using electrochemical impedance spectroscopy (EIS) at open circuit potential in a 3.5 wt.% NaCl and 2 wt.% H2SO4 solutions. The EIS data acquired were curve fitted and analysed by equivalent circuit models to calculate the pore resistance, the charge transfer resistance and the capacitance. The Nyquist diagrams of all systems showed one part of the semicircle which could relate that reaction is a one step process, except for the AlCrN/TiCrSiN and AlCrN/AlCrN + CrN coatings in H2SO4 solution, for which two semicircles related to active corrosion in substrate alloy were found. However, from the Bode plots, it was possible to identify two the time constants for all systems exposed to NaCl and H2SO4 solutions. According to electrochemical results, the corrosion resistance of the AlCrN/TiSiN coating was better in the NaCl solution, whereas the AlCrN/AlCrN + CrN coating show better performance in the Sulphuric Acid solutions.

24 February 2023 in Metals
Verified
Journal Article
Open access
PDF file
JJJesus Jáquez-Muñoz
Jesus Jáquez-Muñoz
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
CMCe Tochtli Méndez-Ramírez
Ce Tochtli Méndez-Ramírez
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
Francisco Humberto Estupinan-LopezFrancisco Humberto Estupinan-Lopez
Francisco Humberto Estupinan-Lopez
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
The anodization of titanium has been an excellent option for protecting titanium and its alloys from corrosive environments such as acids and chloride systems, by generating a homogenous oxide layer. The objective of the current investigation was to evaluate the electrochemical corrosion behavior of alloys Ti-6Al-2Sn-4Zr-2Mo and Ti-6Al-4V anodized in 1M H2SO4 and H3PO4 solutions at a current density of 2.5 × 10–3 A/cm2. The anodization’s electrochemical characterization was achieved in NaCl and H2SO4 at 3.5% wt. electrolytes. Scanning electron microscopy (SEM) was employed to determine the anodized thickness and morphology. Cyclic potentiodynamic polarization (CPP) and electrochemical impedance spectroscopy (EIS), based on ASTM G61-86 and G106-15 Standards, were the electrochemical techniques mainly employed. The anodized samples presented a change in Ecorr values and a higher passivation zone. The EIS plot showed a higher resistance for samples anodized in H3PO4 and Ti-6Al-2Sn-4Zr-2Mo.

28 June 2024 in Coatings
Verified
Journal Article
Open access
PDF file
JJJesus Jáquez-Muñoz
Jesus Jáquez-Muñoz
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
CMCe Tochtli Méndez-Ramírez
Ce Tochtli Méndez-Ramírez
MCMartha Guadalupe Carrera-Ramirez
Martha Guadalupe Carrera-Ramirez
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
Ti and Ti alloys are employed in demanding industries such as aerospace, automotive, biomedical, aeronautic, structural, naval, and chemical, thanks to their resistance to corrosion due to the formation of the TiO2 film on the surface. Diverse research has established that different corrosive media could attack the oxide layer. One way to generate a stable, compact, and continuous oxide film is through anodizing treatment. The efficiency of anodization depends on diverse factors such as the microstructure, chemical composition of alloys, pH of electrolyte, time, and temperature of anodizing. This review aims to examine the corrosion resistance of the anodized layer on Ti and Ti alloys, with different parameters. The discussion is centered on the influence of the different parameters and alloy properties in the effectivity of anodizing when they are characterized by electrochemical techniques while studying the behavior of oxide.

29 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
ALAbigail Landa-Sánchez
Abigail Landa-Sánchez
JGJuan Bosch Giner
Juan Bosch Giner
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
RCRene Croche
Rene Croche
LLLaura Landa-Ruiz
Laura Landa-Ruiz
David M. BastidasDavid M. Bastidas
David M. Bastidas
Novel green concrete (GC) admixtures containing 50% and 100% recycled coarse aggregate (RCA) were manufactured according to the ACI 211.1 standard. The GC samples were reinforced with AISI 1080 carbon steel and AISI 304 stainless steel. Concrete samples were exposed to 3.5 wt.% Na2SO4 and control (DI-water) solutions. Electrochemical testing was assessed by corrosion potential (Ecorr) according to the ASTM C-876-15 standard and a linear polarization resistance (LPR) technique following ASTM G59-14. The compressive strength of the fully substituted GC decreased 51.5% compared to the control sample. Improved corrosion behavior was found for the specimens reinforced with AISI 304 SS; the corrosion current density (icorr) values of the fully substituted GC were found to be 0.01894 µA/cm2 after Day 364, a value associated with negligible corrosion. The 50% RCA specimen shows good corrosion behavior as well as a reduction in environmental impact. Although having lower mechanical properties, a less dense concrete matrix and high permeability, RCA green concrete presents an improved corrosion behavior thus being a promising approach to the higher pollutant conventional aggregates.