Xianglin Ren

Xianglin Ren

Auto-generated profile, based on publicly available information

Xianglin Ren

College of Biomedical Engineering and Instrument Science, Biosensor National Special Laboratory, Zhejiang University, Hangzhou, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YZYiming Zhang
Yiming Zhang
XRXianglin Ren
Xianglin Ren
XLXiao Liang
Xiao Liang
Xuesong YeXuesong Ye
Xuesong Ye
CZCongcong Zhou
Congcong Zhou
This study proposed a refined BP prediction strategy that using single-channel photoplethysmography (PPG) signals to stratify populations by cardiovascular status before BP estimation. Combining demographic characteristics (age, gender) and pulse wave morphological features, the random forest was applied to screen two kinds of typical cardiovascular diseases (CVDs), with an accuracy of 92.2%. A deep learning model (BiLSTM-At) was proposed to estimate the long-term BP trend for different CVD groups. Transfer learning technique was used for personalized modeling to reduce computational complexity while improving performance. The method was validated on 255 patients with different CVDs. The mean absolute errors (MAEs) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimation were 2.815 mmHg and 1.876 mmHg for normal subjects, 3.024 mmHg and 1.334 mmHg for AF subjects, and 4.444 mmHg and 2.549 mmHg for CA subjects. The results met the American Association for the Advancement of Medical Instrumentations (AAMI) and British Hypertension Society (BHS) Class A criteria. This indicated that our strategy has good performance and can realize long-term monitoring of BP through a small batch samples, with the potential to implement real-time monitoring in healthy devices.

28 January 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YZYiming Zhang
Yiming Zhang
CZCongcong Zhou
Congcong Zhou
XRXianglin Ren
Xianglin Ren
QWQing Wang
Qing Wang
HWHongwei Wang
Hongwei Wang
Xuesong YeXuesong Ye
Xuesong Ye
The real-time tracking of human physiopathology states can significantly enhance the quality of personalized healthcare services. Photoplethysmography (PPG) detection is a rapid, portable and non-invasive method for measuring blood flow volume, widely used for monitoring blood pressure (BP) and cardiovascular status. However, continuous BP monitoring technologies based on PPG face numerous challenges in real-world wearable scenarios, such as poor signal quality, complex model computation, and the need for frequent calibration. This work proposed a personalized continuous BP tracking pipeline that performed automatic PPG signal quality grading to reduce the difficulty of model fitting, introduced a lightweight BP model (SCI-GTCN) to alleviate computational complexity, and employed an adaptive calibration strategy to achieve long-term BP monitoring performance under different scenarios. The proposed pipeline was validated using data from 134 subjects in various monitoring scenarios (daytime, nighttime, and abnormal states), assessing the model's performance during rapid BP changes, circadian rhythm fluctuations, and long-term monitoring. The ME±SD was 0.99±7.91/0.36±5.43 mmHg. Overall, the results of our method are within the accuracy requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standards, though the subject distribution differs. The method demonstrated good robustness and applicability, making it convenient for deployment on wearable devices and promising in the healthcare field.

8 April 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XRXianglin Ren
Xianglin Ren
CZCongcong Zhou
Congcong Zhou
Xuesong YeXuesong Ye
Xuesong Ye
Core body temperature (CBT) is a basic physiological parameter that reflects the level of human metabolism and is therefore clinically important for the diagnosis of various diseases. The traditional method of CBT evaluation based on heat flux is susceptible to errors caused by horizontal heat flux and the sensor is usually large in size. In this study, a novel miniaturized sandwich-like CBT monitoring sensor (SCBTS) based on negative temperature coefficient (NTC) temperature sensor and heat flux sensor was constructed. The sandwich-like structure minimized the effect of horizontal heat flux and reduced ambient temperature disturbance. In addition, a novel numerical method was explored to predict CBT during unsteady heat flux. Effectiveness of SCBTS was verified by finite element method (FEM) simulation, mock-up experiments and human experiments. The proposed sensor was effective within the range of human body temperature fluctuations (35°C–42°C) with an average error of 0.02°C on the hot plate. In human trials, resting experiments (eight participants for 13 trials) showed 0.02°C average difference with a 95% CI of [−0.16, 0.12]°C. Furthermore, the sensor showed distinct temperature changes in different periods using exercise experiments (6 participants). The proposed SCBTS continuously monitors temperature without causing inconvenience to the subject, therefore, it is highly suitable for application.

7 September 2024 in Measurement
Verified
Journal Article
Closed access
XRXianglin Ren
Xianglin Ren
YZYiming Zhang
Yiming Zhang
HYHonglian Yang
Honglian Yang
KLKaitai Li
Kaitai Li
Xuesong YeXuesong Ye
Xuesong Ye
CZCongcong Zhou
Congcong Zhou

23 October 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
KLKaitai Li
Kaitai Li
XRXianglin Ren
Xianglin Ren
ZYZhibiao Ying
Zhibiao Ying
CZCongcong Zhou
Congcong Zhou
Xuesong YeXuesong Ye
Xuesong Ye
Accurately estimating energy expenditure (EE) is essential for optimizing motion control strategies in human-in-the-loop (HIL) systems within the field of human-machine interface (HMI). This study aims to propose a method for accurately estimating EE under various movement conditions using a low-cost wearable electrocardiogram (ECG) device and to analyze the impact of various factors on the estimation results. In this study, we introduce an improved snow ablation optimizer (ISAO) to optimize the hyperparameters and input time series window length in a BiLSTM network for predicting EE under diverse motion conditions. ISAO adaptively adjusts the search strategy during different optimization stages by analyzing fitness changes throughout the iterative process. Additionally, the optimized input data window length considers both high-frequency ECG signals and low-frequency EE data collected using the breath-by-breath method, thus avoiding errors from empirical selection. After offline model training, we evaluated the model using test sets comprising multiple time intervals generated by the optimized window length, simulating real online testing scenarios. Experimental results demonstrate that the proposed ISAO-BiLSTM network structure can accurately predict EE across various motion paradigms (RMSE: 56 W; R²: 0.93). This study verifies that the ECG-based deep learning framework has more accurate EE predictions across various motion paradigms compared to those based on heart rate (HR) signals. Additionally, the optimized input data window length is expected to be valuable for real-time EE predictions in HIL HMI applications, as current closed-loop optimization strategies primarily rely on outputting an EE value within a specific time window.