Chamberlin Stéphane Azebaze Mboving

Dr. Chamberlin Stéphane Azebaze Mboving

AGH University of Science and Technology in Cracow
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2021 in Electronics
Verified
Journal Article
Open access
PDF file
CMChamberlin Stéphane Azebaze Mboving
Chamberlin Stéphane Azebaze Mboving
The use of passive harmonic filters (PHFs) in an electrical system is in most cases for the fundamental harmonic reactive power compensation and harmonics mitigation. In comparison to other filters applied to improve the power quality, such as the shunt active power filter or hybrid active power filter, their main advantages are the low investment costs and easy applicability in low-, medium-, and high-voltage electrical systems. However, their installation demands a deep analysis of the electrical system as well as a thorough knowledge of the topology to be installed. Their work efficiency is influenced by the parameters of the electrical system (grid, load, and filter itself) which must be well-known before installation. The aim of this paper is to present an investigation on the work efficiency of the LC passive harmonic filter chosen topologies. The PHFs are investigated in the frequency domain through their impedance versus frequency characteristics as well as in the time domain through an electrical system. A comparative study between filters is also considered. The investigations on the case examples of PHFs are based on simulations and some laboratory studies are also presented.

4 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
CMChamberlin Stéphane Azebaze Mboving
Chamberlin Stéphane Azebaze Mboving
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
AFAndrzej Firlit
Andrzej Firlit
This paper presents the electrical system factors having an influence on the work efficiency and performance of the LC passive harmonic filters (PHFs). Such filters are very often used in industries for the purpose of harmonics mitigation and reactive power compensation. Before their installation in the electrical system, many investigations should be performed in order to ensure their good design as well as work efficiency after connection. In this paper, the factors having an influence on the PHFs work efficiency and performance, such as the grid short-circuit power, primary grid voltage spectrum (voltage measured at the PCC before the filter connection), load reactive power and current characteristic harmonics, manufacturer filter parameters tolerance and filter-detuning phenomena are investigated. Most of the quoted factors are mentioned in the literature, but the novelty of this paper is that, based on the case study example of the single-tuned filter investigated in the laboratory, the influence of those factors on the filter work efficiency are demonstrated, and some solutions and recommendations are proposed. The studies are focused on the design of the single-tuned filter in the laboratory, and some simulation results are presented as well.

1 March 2021 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
CMChamberlin Stéphane Azebaze Mboving
Chamberlin Stéphane Azebaze Mboving
AFAndrzej Firlit
Andrzej Firlit
The shunt active power filter (SAPF) and hybrid active power filter (HAPF) efficiency does not only depends on their designed control system, but also on the parameters of the electrical system in which they are connected. In the electrical system for instance with diode or thyristor rectifier loads, the operating efficiency of the shunt active power filter may not be satisfied at the commutation times, when the rate of current change (di / dt) is high. In the topology of HAPF where the active and passive filters are connected in parallel, the passive filter efficient may depend on the grid parameters. Therefore, the efficiency of such filters can be in certain cases improved by connecting an additional line-reactor in the electrical system. This paper presents an investigation on the influence of the additional line-reactor on the SAPF and HAPF efficiency. The investigation is based on laboratory experiments.

20 October 2023
Verified
Book Chapter
Open access
PDF file
CMChamberlin Stéphane Azebaze Mboving
Chamberlin Stéphane Azebaze Mboving
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
The disturbances observed in the electrical system such as harmonics, asymmetry, flickers, voltage dips and swells, transients, are due to the type of connected devices. The nonlinear devices are the most common ones. Their connection to the electrical system without solution of mitigating their negative influence on supply network can be the cause of poor power quality. There are different types of solutions such as the passive harmonic filters (PHF), the active power filters (APF), the hybrid active power filters (HAPF). Each of those solutions presents some advantages and disadvantages. The chapter is focused on the HAPF, which is the combination of the PHF and shunt active power filter (SAPF) connected in series. Such topology is known in the literature, but still, there are certain problems that need more clarification through detailed studies. For instance, there are not enough recommendations on how to choose the PHF tuning frequency, when it is connected in series with SAPF. The investigations presented in this chapter are very detailed and based on a case study. The proposed control system algorithms of filters (SAPF and HAPF) are presented as well as formulated recommendations.

1 July 2015
Verified
Conference Paper
Closed access
CMChamberlin Stéphane Azebaze Mboving
Chamberlin Stéphane Azebaze Mboving
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
Passive filters are an effective solution to eliminate the harmonics generated by a non-linear load in an electric power system. This paper focuses on C-type filter describing its advantages and disadvantages including properties analysis as well.

22 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
CMChamberlin Stéphane Azebaze Mboving
Chamberlin Stéphane Azebaze Mboving
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
This paper presents a case study in which the influence of the 6-pulse thyristor-bridge input reactor size on the shunt active power filter (SAPF)’s work performance is investigated. The purpose of using an SAPF in the power system is in most cases for fundamental harmonic reactive power compensation, harmonics and asymmetry mitigation. The work efficiency of such a filter depends not only on the designed control system, interface filter and dc-link capacitor parameters, but also on the parameters of the electrical system in which it is connected. Therefore, it is necessary to study and know the power system (supplier and consumer sides) before its installation. For instance, in the electrical system with diode or thyristor-bridge as loads, the SAPF performance efficiency may not be satisfied due to the high rate of current change (di/dt) at the points of commutation notches. In this paper, the performed simulation and laboratory experiments show that for a better operating efficiency of the SAPF, the input reactor parameters should be selected based not only on the effective reduction in the inverter switching ripple or the control system demand, but also on the parameters of the load, such as the parameters of the diode or thyristor-bridge input reactor. Apart from the experimental demonstrations on how the input reactor size influences the SAPF work efficiency, the novelties in this paper are: the formulated recommendations on how to choose the SAPF input reactor parameters (the SAPF is more efficient in terms of harmonics, asymmetry and reactive power mitigation when the inductance of its input reactor (L-filter) is smaller than the one of the diode or thyristor-bridge input reactor); the proposed SAPF control system; the proposed expressions to compute the SAPF input reactor inductance, DC voltage and capacitor.