Zbigniew Hanzelka

Prof. Zbigniew Hanzelka

AGH - University of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
YSYaroslav Elievich Shklayrskiy
Yaroslav Elievich Shklayrskiy
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
Aleksandr SkamyinAleksandr Skamyin
Aleksandr Skamyin
The paper considers the influence of harmonics on the operating of electrical energy meters in a network with nonlinear loads. It is shown that electronic static meters of active energy are tested in the presence of distortions, and electronic static meters of reactive energy accuracy requirements do not take into account the possible presence of harmonics. It is revealed that the maximum influence on the error in active energy metering is exerted by the number of harmonics taken into account and their amplitude, and the error in reactive energy metering is additionally influenced by the phase angle at the fundamental and harmonic frequencies, which has been confirmed in laboratory conditions. Additionally, experimental studies of the capacitor bank’s influence on reactive energy metering has been carried out in the presence of nonlinear electrical loads. It is shown that when capacitor banks are connected, the error in reactive energy measurement and variation range of the phase shift angle of harmonics significantly increases. The assessment of the computational error of reactive power metering according to various equations were carried out based on the field measurements. If the voltage and current distortion values do not exceed the permissible values, the error can be estimated at, at most, 5–7%.

6 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
BMBabar Muhammad
Babar Muhammad
Jakub GrelaJakub Grela
Jakub Grela
Andrzej OżadowiczAndrzej Ożadowicz
Andrzej Ożadowicz
PNPhuong H. Nguyen
Phuong H. Nguyen
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
IKI. G. Kamphuis
I. G. Kamphuis
Effective Energy Management with an active Demand Response (DR) is crucial for future smart energy system. Increasing number of Distributed Energy Resources (DER), local microgrids and prosumers have an essential and real influence on present power distribution system and generate new challenges in power, energy and demand management. A relatively new paradigm in this field is transactive energy (TE), with its value and market-based economic and technical mechanisms to control energy flows. Due to a distributed structure of present and future power system, the Internet of Things (IoT) environment is needed to fully explore flexibility potential from the end-users and prosumers, to offer a bid to involved actors of the smart energy system. In this paper, new approach to connect the market-driven (bottom-up) DR program with current demand-driven (top-down) energy management system (EMS) is presented. Authors consider multi-agent system (MAS) to realize the approach and introduce a concept and standardize the design of new Energy Flexometer. It is proposed as a fundamental agent in the method. Three different functional blocks have been designed and presented as an IoT platform logical interface according to the LonWorks technology. An evaluation study has been performed as well. Results presented in the paper prove the proposed concept and design.

23 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
Krzysztof PiatekKrzysztof Piatek
Krzysztof Piatek
AFAndrzej Firlit
Andrzej Firlit
KCKrzysztof Chmielowiec
Krzysztof Chmielowiec
MDMateusz Dutka
Mateusz Dutka
SBSzymon Barczentewicz
Szymon Barczentewicz
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
Quality of power supply in power distribution systems requires continuous measurement using power quality analyzers installed in the grid. The paper reviews the published methods for optimal location of metering points in distribution systems in the context of power quality metering and assessment. Three methods have been selected for detailed analysis and comparative tests. It has been found that utilization of the methods is possible, but their performance varies highly depending on the test grid’s topology. Since the methods rely on the state estimation approach, their performance is strictly related to observability analysis. It has been found that standard observability analysis used for typical state estimation problem yields ambiguous results when applied to power quality assessment. Inherited properties of the selected methods are also analyzed, which allows for the formulation of general recommendations about optimal selection of metering points in a distribution system.

4 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
CMChamberlin Stéphane Azebaze Mboving
Chamberlin Stéphane Azebaze Mboving
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
AFAndrzej Firlit
Andrzej Firlit
This paper presents the electrical system factors having an influence on the work efficiency and performance of the LC passive harmonic filters (PHFs). Such filters are very often used in industries for the purpose of harmonics mitigation and reactive power compensation. Before their installation in the electrical system, many investigations should be performed in order to ensure their good design as well as work efficiency after connection. In this paper, the factors having an influence on the PHFs work efficiency and performance, such as the grid short-circuit power, primary grid voltage spectrum (voltage measured at the PCC before the filter connection), load reactive power and current characteristic harmonics, manufacturer filter parameters tolerance and filter-detuning phenomena are investigated. Most of the quoted factors are mentioned in the literature, but the novelty of this paper is that, based on the case study example of the single-tuned filter investigated in the laboratory, the influence of those factors on the filter work efficiency are demonstrated, and some solutions and recommendations are proposed. The studies are focused on the design of the single-tuned filter in the laboratory, and some simulation results are presented as well.

9 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
KCKrzysztof Chmielowiec
Krzysztof Chmielowiec
ŁTŁukasz Topolski
Łukasz Topolski
APAleks Piszczek
Aleks Piszczek
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
The presently observed rapid increase in photovoltaic (PV) micro-installation connections to low-voltage networks, resulting from numerous financial support programmes, European Union (EU) energy policy and growing social awareness of environmental and economic issues, raise the question if PV inverters widely available in EU market fulfil the numerous technical requirements specified in European and Polish regulations. The paper presents the results of an experimental study carried out on three PV Inverters widely available in the EU in accordance with the EU network code NC RfG, standard EN 50549-1:2019 and internal Polish distribution system operators’ (DSOs’) regulations, governing PV inverter cooperation with the low-voltage distribution network. The laboratory test stand scheme and its description are presented. In each test, at least one of the inverters encountered issues, either with the operation in required frequency ranges (one PV inverter), activating reactive power control modes (all three PV inverters), maintaining required power generation gradient after tripping (one PV inverter) or under-voltage ride through immunity (one PV inverter). The obtained results have shown that all tested PV inverters did not meet requirements that are the key to maintaining reliable and safe operation of transmission and distribution electrical networks.

18 April 2008
Verified
Book Chapter
Closed access
PDF file
Angelo BagginiAngelo Baggini
Angelo Baggini
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka