Quality of power supply in power distribution systems requires continuous measurement using power quality analyzers installed in the grid. The paper reviews the published methods for optimal location of metering points in distribution systems in the context of power quality metering and assessment. Three methods have been selected for detailed analysis and comparative tests. It has been found that utilization of the methods is possible, but their performance varies highly depending on the test grid’s topology. Since the methods rely on the state estimation approach, their performance is strictly related to observability analysis. It has been found that standard observability analysis used for typical state estimation problem yields ambiguous results when applied to power quality assessment. Inherited properties of the selected methods are also analyzed, which allows for the formulation of general recommendations about optimal selection of metering points in a distribution system.
This paper presents the electrical system factors having an influence on the work efficiency and performance of the LC passive harmonic filters (PHFs). Such filters are very often used in industries for the purpose of harmonics mitigation and reactive power compensation. Before their installation in the electrical system, many investigations should be performed in order to ensure their good design as well as work efficiency after connection. In this paper, the factors having an influence on the PHFs work efficiency and performance, such as the grid short-circuit power, primary grid voltage spectrum (voltage measured at the PCC before the filter connection), load reactive power and current characteristic harmonics, manufacturer filter parameters tolerance and filter-detuning phenomena are investigated. Most of the quoted factors are mentioned in the literature, but the novelty of this paper is that, based on the case study example of the single-tuned filter investigated in the laboratory, the influence of those factors on the filter work efficiency are demonstrated, and some solutions and recommendations are proposed. The studies are focused on the design of the single-tuned filter in the laboratory, and some simulation results are presented as well.
Over the last few years, a dynamic increase in the installed capacity of distributed energy sources has been observed, with the largest share being photovoltaic sources. The power grid is a system of connected vessels, and changing the structure of electricity production has a specific impact on the operation of this network, which makes it necessary to study the impact of the sources on the power system. The current and projected increase in the number of connected installations will make the issues of interaction and cooperation of distributed sources with the network extremely important. The article presents an analysis of the impact of a photovoltaic farm on selected parameters of the quality of electricity supply. This analysis was made on the basis of simulation results in a computer program and measurement tests carried out on a real photovoltaic farm with a capacity of 1.8 MW connected to the medium voltage power grid. The impact of the farm-generated power on the values of fundamental indicators of the quality of electricity supply, such as voltage deviations, voltage asymmetry factors, and voltage distortions factors, is presented. These relationships were determined based on the correlation and regression analysis of individual electrical quantities.
This paper presents an algorithm for finding the optimal control for a current controller that operates as a part of a control system of a shunt active power filter. The algorithm is based upon the Karush–Kuhn–Tucker conditions for finding an optimal value where control signal is limited and constraints create a cube. The explicit solution of the Karush–Kuhn–Tucker problem is presented and simplified calculations are given to lower calculation complexity. The presented Karush–Kuhn–Tucker algorithm is compared with a classical PI controller. It is given the algorithm for finding the optimal parameters of the PI controller and the behavior of the PI controller is compared with the presented algorithm. Attention has been paid to the saturation of controllers in commutation states of load currents, which has a negative impact on the final performance of the controllers and the controlled shunt active power filter. The paper also presents the software and hardware platforms applied to run the presented algorithms in real-time. For both controllers, the shunt active power filter response is shown using real experimental results. The results of the experiments prove better behavior regarding the presented algorithm, especially in the case of commutative load currents, where the output signals from other controllers become saturated.
Monitoring power quality (PQ) indicators is an important part of modern power grids’ maintenance. Among different PQ indicators, flicker severity coefficients Pst and Plt are measures of voltage fluctuations. In state-of-the-art PQ measuring devices, the flicker measurement channel is usually implemented as a dedicated processor subsystem. Implementation of the IEC 61000-4-15 compliant flicker measurement algorithm requires a significant amount of computational power. In typical PQ analysers, the flicker measurement is usually implemented as a part of the meter’s algorithm performed by the main processor. This paper considers the implementation of the flicker measurement as an FPGA module to offload the processor subsystem or operate as an IP core in FPGA-based system-on-chip units. The measurement algorithm is developed and validated as a Simulink diagram, which is then converted to a fixed-point representation. Parts of the diagram are applied for automatic VHDL code generation, and the classifier block is implemented as a local soft-processor system. A simple eight-bit processor operates within the flicker measurement coprocessor and performs statistical operations. Finally, an IP module is created that can be considered as a flicker coprocessor module. When using the coprocessor, the main processor’s only role is to trigger the coprocessor and read the results, while the coprocessor independently calculates the flicker coefficients.
This paper describes a laboratory-based comparison of power quality class A analyzers, with respect to voltage harmonic distortion measurements. The tested measuring instruments were designed in accordance to the requirements of the IEC 61000-4-30 standard. The purpose of these tests was to assess the dispersion of results of analyzers connected to a common measuring point. The expectation is that simultaneous measurements of the same voltage signal should result in a readings dispersion not greater than ±5% of the measured value. The described tests are part of a complex evaluation of metrological properties of power quality analyzers carried out at the AGH University of Science and Technology, Krakow. Detailed results of harmonic tests, comparisons, and conclusions are presented.