Dong Ho Rie

Prof. Dr. Dong Ho Rie

Professor, Safety Engineering, Incheon National University (S.Korea)
+2
orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2006 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
Dong Ho RieDong Ho Rie
Dong Ho Rie
MHMyung-Whan Hwang
Myung-Whan Hwang
SKSeong-Jung Kim
Seong-Jung Kim
SYSung-Wook Yoon
Sung-Wook Yoon
JKJae-Woong Ko
Jae-Woong Ko
HKHa-Yong Kim
Ha-Yong Kim

28 June 2016 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Dong Ho RieDong Ho Rie
Dong Ho Rie
JLJang-Won Lee
Jang-Won Lee
SKSeonwoong Kim
Seonwoong Kim
The purpose of this research is to evaluate the fire-extinguishing performance of a compressed air foam system at different mixing ratios of pressurized air. In this system, compressed air is injected into an aqueous solution of foam and then discharged. The experimental device uses an exclusive fire-extinguishing technology with compressed air foam that is produced based on the Canada National Laboratory and UL (Underwriters Laboratories) 162 standards, with a 20-unit oil fire model (Class B) applied as the fire extinguisher. Compressed air is injected through the air mixture, and results with different air-to-aqueous solution foam ratios of 1:4, 1:7, and 1:10 are studied. In addition, comparison experiments between synthetic surfactant foam and a foam type which forms an aqueous film are carried out at an air-to-aqueous solution foam ratio of 1:4. From the experimental results, at identical discharging flows, it was found that the fire-extinguishing effect of the aqueous film-forming foam is greatest at an air-to-aqueous solution foam ratio of 1:7 and weakest at 1:10. Moreover, the fire-extinguishing effect of the aqueous film-forming foam in the comparison experiments between the aqueous film-forming foam and the synthetic surfactant foam is greatest.

1 November 2009 in Journal of Loss Prevention in the Process Industries
Verified
Journal Article
Closed access
SYSung-Wook Yoon
Sung-Wook Yoon
Dong Ho RieDong Ho Rie
Dong Ho Rie
HKHa-Young Kim
Ha-Young Kim

1 October 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Min Chul LeeMin Chul Lee
Min Chul Lee
YKYun Seok Kim
Yun Seok Kim
Dong Ho RieDong Ho Rie
Dong Ho Rie

16 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
CKChun Kwanok
Chun Kwanok
JKJeonggon Kim
Jeonggon Kim
Dong Ho RieDong Ho Rie
Dong Ho Rie
According to the Fire Statistics Yearbook of the National Fire Agency of the Republic of Korea, the total number of fires in 2018 was 42,338, which resulted in 2500 victims and amounted to property damages of approximately 560 billion KRW. The number of fires in buildings where wood was used as a finishing material was 28,013 (66%) in that period. To minimize human and property damage, composite materials were prepared by mixing wood particles with expandable graphite. The physical and thermal properties of the composite materials were investigated. It was observed that the expansion rate increased by 341.7% according to the expandable graphite content. Additionally, the total heat released and the thermal conductivity decreased from 38.63 to 2.5 MJ/m2 and from 24.62 to 7.8 W/m·K. The time to inactivity of white mouse in the smoke toxicity test was 14.9 min and exceeded the toxicity standard for flame retardant performance. The expandable graphite added to composite materials adopted worm-like shapes as a result of combustion, and it formed a fine lattice layer structure with 16–22 μm gaps that could reduce thermal conductivity. In addition, we can minimize the damage to people and property in the event of a fire.

15 May 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
CAChan-Sol Ahn
Chan-Sol Ahn
HKhyeongwoo kim
hyeongwoo kim
ICInsu Choi
Insu Choi
Dong Ho RieDong Ho Rie
Dong Ho Rie
The continued increase in human lifespans is accelerating the aging of the population in most countries. The increase in elderly care facilities corresponds to a relative increase in the number of people who are vulnerable in the context of evacuation. For example, an elderly care hospital is a representative facility for vulnerable populations as regards evacuation, as residents in such a hospital cannot evacuate themselves in the event of a fire. It is therefore necessary for such buildings to formulate detailed evacuation plans that consider the walking situations of their residents in the event of a disaster. In this study, the fire dynamics simulator (FDS) was used to calculate the available safety escape time (ASET)—which is the point at which evacuation is impossible from the ignition time of the fire—for inpatients in nursing hospitals. The required safety escape time (RSET), which is the time required to move to a safe place, was calculated by reflecting a patient’s evacuation speed using Pathfinder. In addition, the evacuation route was simulated with three variables—stairs, elevators, and ramps—along with the movement pattern. The simulations of evacuation performance evaluation based on time analysis showed that there were differences in the number of fatalities depending on the choice of evacuation routes and movement patterns for each disabled group. Evacuation using ramps was confirmed to reduce fatalities from at least 48 to up to 60 people compared to evacuation using stairs or elevators. The usage of ramp evacuation in elderly care hospitals has proved to be superior to other evacuation routes in ensuring the safety of vulnerable persons during fire evacuation.