The continued increase in human lifespans is accelerating the aging of the population in most countries. The increase in elderly care facilities corresponds to a relative increase in the number of people who are vulnerable in the context of evacuation. For example, an elderly care hospital is a representative facility for vulnerable populations as regards evacuation, as residents in such a hospital cannot evacuate themselves in the event of a fire. It is therefore necessary for such buildings to formulate detailed evacuation plans that consider the walking situations of their residents in the event of a disaster. In this study, the fire dynamics simulator (FDS) was used to calculate the available safety escape time (ASET)—which is the point at which evacuation is impossible from the ignition time of the fire—for inpatients in nursing hospitals. The required safety escape time (RSET), which is the time required to move to a safe place, was calculated by reflecting a patient’s evacuation speed using Pathfinder. In addition, the evacuation route was simulated with three variables—stairs, elevators, and ramps—along with the movement pattern. The simulations of evacuation performance evaluation based on time analysis showed that there were differences in the number of fatalities depending on the choice of evacuation routes and movement patterns for each disabled group. Evacuation using ramps was confirmed to reduce fatalities from at least 48 to up to 60 people compared to evacuation using stairs or elevators. The usage of ramp evacuation in elderly care hospitals has proved to be superior to other evacuation routes in ensuring the safety of vulnerable persons during fire evacuation.
The impact of non-face-to-face contact following the COVID-19 pandemic has emerged as a social problem and has increased the amount of wastepaper, mainly in home delivery boxes. The appropriate recycling of paper waste is an area where sustainable growth is required in terms of the net environment system and carbon neutrality practice. Therefore, in this study, a specimen of building finishing material using wastepaper was produced using a custom-made large wet cellulose (LWC) 3D printer, and the site applicability of the fire performance was evaluated. The specimen of the building finish material was a mixture of wastepaper and ceramic binder, and the molding of the specimen was uniformly produced by a cylinder injection-type LWC 3D printer. The production reliability of the 3D printer was analyzed by measuring the mass and density of the specimen. The uniformity of the mass and density of the manufactured building finishes were confirmed to have standard deviations of ±0.05 g and ±0.01 g/cm3, respectively. The uniformity of the fire performance of specimens was confirmed by checking the relative standard deviation (RSD) value of ±3% under the same ceramic addition conditions from ISO 5660-1. Through the mass and density analysis and fire performance analysis of the building finishing materials, it was confirmed that the same mass, density, and fire performance can be produced simultaneously, and manufacturing using LWC 3D printers has been confirmed to be effective in developing uniform semi-non-combustible and retardant building materials.
As the construction of high-rise buildings increases to solve residential spaces caused by high density population concentration, the occurrence of fire accidents in high-rise buildings is also increasing. The primary cause of fire damage in high-rise buildings is the spread of fire caused by exterior wall finishes. Therefore, it is essential to develop semi-non-combustible finishes that can be applied to high-rise buildings to prevent the spread of fire due to exterior wall finishes. To address this issue, numerous studies are being conducted to develop flame retardant finishing materials that reduce heat release rate and total heat release. A double flame retardant mixed waste paper with expandable graphite and magnesium hydroxide was manufactured to improve the fire performance of cellulose building finishing materials. Total heat release (THR), CO, and CO2 Generation changes were measured using a cone calorimeter, and thermal diffusion rate was measured through the LFA 1000 experiment. The correlation of total heat release, CO generation, CO2 generation, and mass reduction rate by variation of expandable graphite's mesh size at double flame-retardant waste paper were secured through a cone calorimeter test. The thermal diffusion rate data of the specimen were secured through the LFA 1000 experiment. Through experiments, it has been confirmed that specimens using specific expandable graphite particles can be utilized as fire-resistant finishing materials in construction, ensuring fire resistance performance.
30 April 2020 in Journal of the Korean Society of Hazard Mitigation
The vulnerabilities of high-rise buildings to fires and the safe evacuation of the occupants therein have been consistently highlighted in the media. Unexpected natural disasters that occur frequently such as earthquakes increase the potential risk in large cities. If an earthquake with a magnitude that exceeds the load for safety design occurs and causes a fire in a high-rise building, it would lead to serious casualties among the occupants evacuating the building. This study represented the stairs in high-rise buildings using several full-scale models and examined the characteristics of a high temperature plume rising vertically from the ignition source using numerical analysis with Fire Dynamics Simulator (FDS). We analyzed the effects of calorific value and ventilation in the middle floors and examined the time taken by a plume rising vertically from the stairs to reach each floor. Furthermore, the empirical line suggested by McCaffrey (1979) was used to compare the characteristics of a plume rising vertically inside stairs and in a limited space with those of a plume rising vertically in an open space. Based on the time taken by a plume front to rise, which is calculated based on numerical analyses, this study identified and suggested an experiment equation to make it possible to predict the time taken by a plume to rise from the stairs in a typical high-rise building.
31 December 2018 in Journal of the Korean Society of Hazard Mitigation
Single-cell-based experiments were conducted to evaluate the thermal runaway time of 18650 secondary batteries and the thermal runaway suppression on cooling with different extinguishing agents using the relative delay factor. Lithium-ion, lithium iron phosphate (LiFePO4), and sodium-ion batteries were tested using forced heating through an external controller. The gas venting observed in the battery vent was defined as the pre-runaway stage, in which water, foam, and liquid chemical agents were applied before thermal runaway. The cooling and suppression effects of each agent were analyzed and compared with the delay factor in the absence of treatment. The suppression performance was dependent on battery chemistry, and no single treatment showed consistent effectiveness across all cell types.