Seonwoong Kim

Prof. Seonwoong Kim

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2016 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Dong Ho RieDong Ho Rie
Dong Ho Rie
JLJang-Won Lee
Jang-Won Lee
SKSeonwoong Kim
Seonwoong Kim
The purpose of this research is to evaluate the fire-extinguishing performance of a compressed air foam system at different mixing ratios of pressurized air. In this system, compressed air is injected into an aqueous solution of foam and then discharged. The experimental device uses an exclusive fire-extinguishing technology with compressed air foam that is produced based on the Canada National Laboratory and UL (Underwriters Laboratories) 162 standards, with a 20-unit oil fire model (Class B) applied as the fire extinguisher. Compressed air is injected through the air mixture, and results with different air-to-aqueous solution foam ratios of 1:4, 1:7, and 1:10 are studied. In addition, comparison experiments between synthetic surfactant foam and a foam type which forms an aqueous film are carried out at an air-to-aqueous solution foam ratio of 1:4. From the experimental results, at identical discharging flows, it was found that the fire-extinguishing effect of the aqueous film-forming foam is greatest at an air-to-aqueous solution foam ratio of 1:7 and weakest at 1:10. Moreover, the fire-extinguishing effect of the aqueous film-forming foam in the comparison experiments between the aqueous film-forming foam and the synthetic surfactant foam is greatest.

2 May 2016 in Applied Sciences
Verified
Journal Article
Open access
PDF file
THTaehun Ha
Taehun Ha
JKJeongwon Ko
Jeongwon Ko
SLSangho Lee
Sangho Lee
SKSeonwoong Kim
Seonwoong Kim
JJJieun Jung
Jieun Jung
Dae-Jin KimDae-Jin Kim
Dae-Jin Kim
This paper presents a case study on the rehabilitation of a fire-damaged structure and describes the results of a site investigation and tests, leading to a plan for the rehabilitation of the structure. The fire took place in the main control room of a thermal power plant and lasted about three hours until it was finally extinguished. To set up a rehabilitation plan for the damaged structure, a visual inspection of the damaged condition was first carried out, which was followed by analysis and on-site material tests indicating the degree of neutralization progress in the remaining structure. Specimens of damaged concrete and reinforcing bars were sampled and tested for their residual strengths. As a conclusion, two methods of rehabilitation were suggested considering the current condition of the structure and the sequence of construction.

25 January 2015 in Steel and Composite Structures
Verified
Journal Article
Closed access
SKSeonwoong Kim
Seonwoong Kim
KLKyungkoo Lee
Kyungkoo Lee

31 January 2020 in Journal of the Earthquake Engineering Society of Korea
Verified
Journal Article
Closed access
SKSeonwoong Kim
Seonwoong Kim
KLKyungkoo Lee
Kyungkoo Lee

18 February 2021 in International Journal of Steel Structures
Verified
Journal Article
Closed access
PDF file
SKSeonwoong Kim
Seonwoong Kim

27 March 2019 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
PDF file
SKSeonwoong Kim
Seonwoong Kim
The lateral load-resisting system of high-rise buildings in regions of low and moderate seismicity and strong wind such as the typhoon in the Korean peninsula considers the wind load as the governed lateral force so that the practical structural engineer tends to skip the evaluation against the seismic load. This study is to investigate wind-designed steel diagrid buildings located in these regions and check the possibility of the elastic design of them out. To this end, first, the diagrid high-rise buildings were designed to satisfy the wind serviceability criteria specified in KBC 2016. Then, the response spectrum analyses were performed under various slenderness ratio and wind exposures. The analyses demonstrated the good seismic performance of these wind-designed diagrid high-rise buildings because of the significant over-strength induced by the lateral load-resisting system of high-rise buildings. Also, the analysis results showed that the elastic seismic design process of some diagrid high-rise buildings may be accepted based on slenderness ratios in all wind exposures.