Daniela da Costa Leite Coelho

Dr. Daniela da Costa Leite Coelho

Departamento de Engenharia e Ciências Ambientais, Universidade Federal Rural do Semi-Árido, Mossoró, Rio Grande do Norte, Brazil
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Revista Brasileira de Engenharia Agrícola E Ambiental
Verified
Journal Article
Open access
PDF file
HVHudson S. M. Vale
Hudson S. M. Vale
DCDanniely O. Costa
Danniely O. Costa
Rafael Oliveira BatistaRafael Oliveira Batista
Rafael Oliveira Batista
FOFrancisco de A. de Oliveira
Francisco de A. de Oliveira
JMJosé Francismar de Medeiros
José Francismar de Medeiros
DCDaniela da Costa Leite Coelho
Daniela da Costa Leite Coelho
The objective of this study was to evaluate the uniformity of distribution in drip units applying dilutions of treated water produced by oil exploration. The experiment was set up in a completely randomized design in a split-split-plot scheme, with three replicates. The plots were composed of the treatments P0 - 100% groundwater, control; P10 - 90% groundwater and 10% produced water; P20 - 80% groundwater and 20% produced water; P30 - 70% groundwater and 30% produced water; and P40 - 60% groundwater and 40% produced water; the subplots had the types of non-pressure compensating drippers (D1 - 1.6 L h-1, Netafim Super Typhoon, D2 - 1.6 L h-1, Netafim Streamline and D3 - 1.7 L h-1, NaanDanJain TalDrip); and the sub-subplots contained the evaluation times (0, 40, 80, 120 and 160 h). Distribution uniformity and statistical uniformity coefficients were evaluated every 40 h, until completing 160 h. The pH of the dilutions was the attribute posing the highest risk of clogging to the emitters. Also in relation to dilutions, P40 caused greater application non-uniformity in D2, while the highest values of application uniformity were achieved in treatments P10 and P20 with D1 and D3, indicating the effectiveness of dilution in minimizing clogging.

1 December 2018 in Revista Caatinga
Verified
Journal Article
Open access
PDF file
HVHudson Salatiel Marques Vale
Hudson Salatiel Marques Vale
DCDanniely de Oliveira Costa
Danniely de Oliveira Costa
Rafael Oliveira BatistaRafael Oliveira Batista
Rafael Oliveira Batista
DCDaniela da Costa Leite Coelho
Daniela da Costa Leite Coelho
AFAlex Pinheiro Feitosa
Alex Pinheiro Feitosa
Drip irrigation with diluted sanitary landfill leachate favors the development of grasses on the landfill surface, however, the clogging of emitters of the irrigation systems is the major obstacle for this practice. The objective of this study was to select empirical models of the Christiansen's uniformity coefficient, distribution uniformity coefficient, and statistical uniformity coefficient of drip irrigation sets applying sanitary landfill leachate diluted in water as a function of time of operation, and quality of the effluent. An experiment was conducted in a completely randomized experimental design with three replicates, using a split-split plot arrangement, with operating pressures (70, 140, 210, and 280 kPa) in the plots, types of drippers (G1, 1.65 L h-1; G2, 2.0 L h-1; and G3, 4.0 L h-1) in the subplots, and operating time of the drip irrigation sets (0, 20, 40, 60, 80, 100, 120, 140, and 160 hours) in the sub-subplots. Data regarding hydraulic performance and effluent quality were acquired every 20 hours during 160 hours of operation and subjected to simple and multiple regression analyses. The G3 dripper operating at pressures of 70 and 140 kPa were the combinations that best attenuated biofilm clogging. The linear regression and square root were the models that best represented the reduction in the uniformity of the effluent application as a function of the operating time of the drip irrigation sets. The linear correlations denoted that calcium contents and total coliform population rates were the characteristics of the sanitary landfill leachate that most affected the drip clogging process.

19 March 2020 in Irriga
Verified
Journal Article
Open access
PDF file
JCJorge Luiz DE Oliveira Cunha
Jorge Luiz DE Oliveira Cunha
SSSuedêmio de Lima Silva Silva
Suedêmio de Lima Silva Silva
Rafael Oliveira BatistaRafael Oliveira Batista
Rafael Oliveira Batista
BMBlake Charles Diniz Marques
Blake Charles Diniz Marques
DCDaniela da Costa Leite Coelho
Daniela da Costa Leite Coelho
KSKetson Bruno Silva
Ketson Bruno Silva
MONITORAMENTO DA BIOINCRUSTAÇÃO EM FITAS GOTEJADORAS APLICANDO ÁGUA COM DISTINTAS TEMPERATURAS E SALINIDADES* JORGE LUIZ DE OLIVEIRA CUNHA1; SUEDÊMIO DE LIMA SILVA2; RAFAEL OLIVEIRA BATISTA2; BLAKE CHARLES DINIZ MARQUES2; DANIELA DA COSTA LEITE COELHO2 E KETSON BRUNO SILVA1 1 Doutores em Manejo de Solo e Água, Departamento de Ciências Agronômicas e Florestais, Universidade Federal Rural do Semi-Árido - campus Mossoró- RN, Avenida Francisco Mota, n° 572, Bairro Costa e Silva, Mossoró - RN, CEP: 59.625-900, Brasil, jorgeluiz@ufersa.edu.br; ketsonbruno@hotmail.com. 2 Professores do Departamento de Engenharia e Ciências Ambientais, Universidade Federal Rural do Semi-Árido - campus Mossoró- RN, Avenida Francisco Mota, n° 572, Bairro Costa e Silva, Mossoró - RN, CEP: 59.625-900, Brasil, suedemio@ufersa.edu.br; rafaelbatista@ufersa.edu.br; charles@ufersa.edu.br; daniela.coelho@ufersa.edu.br. *O artigo foi gerado a partir da tese do primeiro autor. 1 RESUMO No campo, as fitas gotejadoras são expostas a agentes físico-químicos e microbiológicos da água de irrigação que potencializam a redução do ciclo operacional pelo processo de bioincrustação nos emissores. Objetivou-se com este trabalho analisar o nível de contribuição da temperatura e salinidade da água subterrânea, na evolução da bioincrustação em emissores de fitas gotejadoras, utilizando-se o coeficiente de uniformidade de distribuição (CUD), vazão dos emissores (Q) e imagens da Microscopia Eletrônica de Varredura (MEV). Para isso, montou-se uma bancada experimental visando o ensaio de três tipos de fitas gotejadoras (MI, MII e MIII) que operaram em quatro ciclos de operação (100, 250, 500 e 750h). As fitas gotejadoras aplicaram água com temperaturas de 20 e 30°C e salinidades que variaram de 0,52 a 2,56 dS m-1. Após o término de cada ciclo de operação, os valores de CUD e Q foram calculados, e coletaram-se amostras das fitas gotejadoras para monitoramento da bioincrustação utilizando-se o MEV. O aumento nos valores de temperatura e salinidade da água não acarretou elevação dos níveis de entupimento. Porém, a fita gotejadora MI, de menor comprimento do emissor e vazão nominal, foi a mais suscetível à bioincrustação, resultante da combinação de mucilagens bacterianas e precipitados químicos. Palavras-chave: qualidade da água, entupimento químico e biológico, vida útil. CUNHA, J. L. O.; SILVA, S. L.; BATISTA, R. O.; MARQUES, B. C. D.; COELHO, D. C. L.; SILVA, K. B. MONITORING BIOFOULING IN DRIP TAPES BY APPLYING WATER WITH DIFFERENT TEMPERATURES AND SALINITIES 2 ABSTRACT In the field, drip tapes are exposed to physical-chemical and microbiological agents in irrigation water that enhance the reduction of the operational cycle by the biofouling process at the emitters. The objective of this work was to analyze the level of contribution of groundwater temperature and salinity in the evolution of biofouling of drip tape emitters, using the distribution uniformity coefficient (DU), emitters flow rate (FR) and Scanning Electron Microscopy (SEM) images. To this end, an experimental bench was set up to test three types of drip tapes (MI, MII and MIII) that operated in four operating cycles (100, 250, 500 and 750h). The drip tapes applied water with temperatures of 20 and 30°C and salinities ranging from 0.52 to 2.56 dS m-1. After the end of each operation cycle, DU and FR values were determined, and samples of the drip tapes were collected to monitor bio-encrustation using SEM. The increase in temperature and salinity values of the water did not increase the levels of clogging. However, drip tape MI, with the shortest emitter length and nominal flow, was the most susceptible to biofouling, resulting from the combination of bacterial mucilage and chemical precipitates. Keywords: water quality, chemical and biological clogging, service life.

1 June 2016 in Revista Caatinga
Verified
Journal Article
Open access
KSKetson Bruno DA Silva
Ketson Bruno DA Silva
Rafael Oliveira BatistaRafael Oliveira Batista
Rafael Oliveira Batista
FMFrancisco de Oliveira Mesquita
Francisco de Oliveira Mesquita
DCDaniela da Costa Leite Coelho
Daniela da Costa Leite Coelho
WSWesley DE Oliveira Santos
Wesley DE Oliveira Santos
The objective of this work was to develop empirical models for hydraulic performance of drippers operating with cashew nut processing wastewater depending on operating time, operating pressure and effluent quality. The experiment consisted of two factors, types of drippers (D1=1.65 L h-1, D2=2.00 L h-1 and D3=4.00 L h-1), and operating pressures (70, 140, 210 and 280 kPa), with three replications. The flow variation coefficient (FVC), distribution uniformity coefficient (DUC) and the physicochemical and biological characteristics of the effluent were evaluated every 20 hours until complete 160 hours of operation. Data were interpreted through simple and multiple linear stepwise regression models. The regression models that fitted to the FVC and DUC as a function of operating time were square root, linear and quadratic, with 17%, 17% and 8%, and 17%, 17% and 0%, respectively. The regression models that fitted to the FVC and DUC as a function of operating pressures were square root, linear and quadratic, with 11%, 22% and 0% and the 0%, 22% and 11%, respectively. Multiple linear regressions showed that the dissolved solids content is the main wastewater characteristic that interfere in the FVC and DUC values of the drip units D1 (1.65 L h-1) and D3 (4.00 L h-1), operating at work pressure of 70 kPa (P1).

1 December 2018 in Revista Caatinga
Verified
Journal Article
Open access
PDF file
DCDaniela da Costa Leite Coelho
Daniela da Costa Leite Coelho
AJAntonio Osmar Medeiros Júnior
Antonio Osmar Medeiros Júnior
KSKetson Bruno da Silva
Ketson Bruno da Silva
NDNildo da Silva Dias
Nildo da Silva Dias
Rafael Oliveira BatistaRafael Oliveira Batista
Rafael Oliveira Batista
The use of landfill leachate (LL) to produce biomass for energy and biofuel purposes is an alternative that minimizes environmental degradation. In this context, the objective of this work was to evaluate the effect of using different rates of LL in the fertigation of sunflower (Helianthus annuus L.) crops. The experiment was conducted in a randomized block design with five treatments and four replications-20 experimental plots. The treatments consisted of control with 100% water from the water supply (WWS) (T1); 80% WWS + 20% LL (T2); 60% WWS + 40% LL (T3); 40% WWS + 60% LL (T4); and 20% WWS + 80% LL (T5). The sunflower crops were grown in a eutrophic Red-Yellow Argisol for 81 days, in Mossoró RN, Brazil. The plant characteristics evaluated-plant height, number of leaves, steam diameter and capitulum diameter-was determined. All variables evaluated presented statistical differences between treatments. In general, plants in the treatment 60% WWS + 40% LL presented better performance regarding the characteristics evaluated.

30 November 2022 in Natural Resources
Verified
Journal Article
Open access
PDF file
APAruza Rayana Morais Pinto
Aruza Rayana Morais Pinto
DCDaniela da Costa Leite Coelho
Daniela da Costa Leite Coelho
PSPaulo Cesar Moura da Silva
Paulo Cesar Moura da Silva
AJAlmir Mariano de Sousa Junior
Almir Mariano de Sousa Junior
RFRaimunda Thyciana Vasconcelos Fernandes
Raimunda Thyciana Vasconcelos Fernandes
AAAna Beatriz Alves de Araújo
Ana Beatriz Alves de Araújo
O Código Florestal brasileiro possibilita a regularização das salinas instaladas em áreas de apicuns, devendo essa ocupação ser comprovada pelo empreendedor. Todavia, isso nem sempre é possível por métodos tradicionais, devido às alterações provocadas pelo empreendimento, fazendo-se necessário o uso do geoprocessamento combinado ao sensoriamento remoto. Assim, objetivou-se mapear a distribuição das áreas de apicuns na planície de inundação do estuário do Rio Apodi-Mossoró, explorado pela atividade salineira, anteriormente à sua ocupação. Para tanto, determinou-se as características fitofisionômicas da área analisada por meio de sensoriamento remoto e geoprocessamento. Para o processamento dos dados, as imagens obtidas foram submetidas ao processo de correção geométrica e recortadas conforme à planície de inundação do estuário avaliado. Após o recorte, procedeu-se a composição colorida de imagem e as bandas escolhidas foram usadas para diferenciar os tipos de uso de solo na área analisada. Por fim, foram elaborados os mapas temáticos com os resultados obtidos. Constatou-se que o apicum ocupava quase 47% da área de estudo, seguido pelas salinas (42,81%) e vegetação de mangue (2,27%), respectivamente. As principais áreas ocupadas por vegetação arbórea de mangue estavam concentradas na região correspondente ao estuário baixo. Na região do médio estuário, observou-se a presença do mangue arbóreo, com uma faixa mais estreita, sendo prontamente substituída pelo apicum, enquanto no alto estuário, a vegetação de mangue aparecia apenas de maneira fragmentada. Dessa forma, pode-se inferir que as salinas instaladas nessa região podem requerer sua regularização ambiental, devendo para isso, assegurar a preservação das áreas ocupadas pela vegetação de mangue.