Davi Edson Sales e Souza

Prof. Dr. Davi Edson Sales e Souza

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2023 in Water Resources Management
Verified
Journal Article
Closed access
PDF file
ESe Souza
e Souza
DSDavi Edson Sales e Souza
Davi Edson Sales e Souza
AMAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
CBClaudio José Cavalcante Blanco
Claudio José Cavalcante Blanco

10 October 2021 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
DSDavi Edson Sales e Souza
Davi Edson Sales e Souza
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
CBClaudio Blanco
Claudio Blanco

13 June 2025 in Processes
Verified
Journal Article
Open access
PDF file
Rodolfo Vitorino RamalhoRodolfo Vitorino Ramalho
Rodolfo Vitorino Ramalho
MFManoel José Mangabeira Pereira Filho
Manoel José Mangabeira Pereira Filho
MSManoel José dos Santos Sena
Manoel José dos Santos Sena
RMRômulo Mendes
Rômulo Mendes
SNSiergberth Ugulino Neto
Siergberth Ugulino Neto
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
In the Amazon, nearly one million people remain without reliable access to electricity. Moreover, the rural electricity grid is a mostly single-phase, ground-return type, with poor energy quality and high expenses. This study examines very low-head micro-hydropower (MHP) sites in the Amazon, emphasizing the integration of multiple axial-flow turbines. It includes an analysis of flow duration curves and key curves, both upstream and downstream, to design an MHP plant with multiple units targeting maximized energy yield. The presence of multiple turbines is crucial due to the substantial annual flow variation in the Amazon rivers. One contribution of this work is its scalable framework for ultra-low-head and high flow variability in small rivers, which is applicable in similar hydrological configurations, such as those typical of the Amazon. The design applies the minimum pressure coefficient criterion to increase turbine efficiency. Computational Fluid Dynamics (CFD) simulations forecast turbine efficiency and flow behavior. The CFD model is validated using experimental data available in the literature on a similar turbine, which is similarly used in this study for cost reasons, with discrepancies under 5%, demonstrating robust predictions of turbine efficiency and head behavior as a function of flow. This study also explores the implications of including inlet guide vanes (IGVs). We use a case study of a small bridge in Vila do Janari, situated in the southeastern part of Pará state, where heads range from 1.4 to 2.4 m and turbine flow rates span from 0.23 to 0.92 m3/s. The optimal configuration shows the potential to generate 63 MWh/year.

23 May 2024 in Heliyon
Verified
Journal Article
Open access
ATAbeyo Mayo Tchada
Abeyo Mayo Tchada
DSDavi Edson Sales e Souza
Davi Edson Sales e Souza
NTNsah-Ko Tchoumboué
Nsah-Ko Tchoumboué
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
PHPatrick Hendrick
Patrick Hendrick
Interest of Pump as Turbine (PAT) is growing with diverse applications in engineering. Usually, the data of PATs are not available in the hands of pump manufacturers. Therefore, performance prediction methods appear as an important research area of PATs. The current prediction methods reposed on expensive, inaccurate and time consuming experimental methods. In the scope of this work, a generic and robust prediction method is built up for a centrifugal impeller PAT. The most significant hydraulic losses were derived in PAT mode, these are namely, the shock losses at the impeller inlet, the swirling losses at the impeller outlet and the impeller wall frictional losses. The Euler head, the available total head and the hydraulic efficiency were computed as well. The global efficiency was computed taking into account the machine mechanical and volumetric efficiencies, enabling therefore to perform comparison of the new prediction method with experimental, computational fluid dynamic (CFD), Rossi and Perez performances prediction methods. From where it resulted a good agreement between the given prediction methods for the entire range of operation, confirming the robustness and the applicability of the developed prediction method. The relative difference between the new prediction method and CFD data and between the new prediction method and experimental data remained higher for lower discharge conditions, notably for extreme part load conditions, where a small error could result in very high relative difference.

21 April 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Rodolfo Vitorino RamalhoRodolfo Vitorino Ramalho
Rodolfo Vitorino Ramalho
MFManoel Pereira Filho
Manoel Pereira Filho
MSManoel Sena
Manoel Sena
RMRômulo Mendes
Rômulo Mendes
SNSiergberth Ugulino Neto
Siergberth Ugulino Neto
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
Nearly one million people in Amazon still don't have reliable access to electricity. Moreover, the rural electricity grid is mostly single-phase, ground-return type, with poor energy quality and high expenses. This study examines very low head micro hydro power (MHP) installations in Amazon, emphasizing the integration of multiple axial-flow turbines. It includes an analysis of flow duration curves and key curves, both upstream and downstream, to design an MHP with two or more units aimed at maximizing annual energy generation. The presence of multiple turbines is crucial due to the substantial annual flow variation in the Amazon rivers. This research supports the design of small, cost-effective axial-flow hydraulic turbines. The design applies the minimum pressure coefficient criterion to increase turbine efficiency. Computational Fluid Dynamics (CFD) simulations forecast turbine efficiency and flow behavior. The CFD model is validated against an existing experimental study from the literature on a propeller turbine with a curved plate blade, which is similarly used in this study due to cost reasons. The study also explores the implications of including inlet guide vanes (IGV). A case study is showcased for a location at a small bridge in Vila do Janari, situated in the southeastern part of Pará state, where heads range from 1.4 to 2.4 m and turbine flow rates span from 0.23 to 0.92 m³/s. The optimal configuration shows the potential to generate 63 MWh/year.

24 July 2023 in Brazilian Journal of Environmental Sciences
Verified
Journal Article
Open access
PDF file
IVIngrid Luna Baia Viana
Ingrid Luna Baia Viana
JBJamile Caroline Moreira Batista
Jamile Caroline Moreira Batista
JSJoão Henrique Macedo Sá
João Henrique Macedo Sá
Rodolfo Vitorino RamalhoRodolfo Vitorino Ramalho
Rodolfo Vitorino Ramalho
RLRaynner Menezes Lopes
Raynner Menezes Lopes
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
As redes de distribuição de água (WDN) são consideradas fonte renovável potencial, apresentando energia de pressão mais que suficiente para entregar água aos usuários. Para controlar a pressão excessiva, comumente as WDN são divididas em áreas de medição distrital (DMA), com válvulas redutoras de pressão (PRV). A energia desperdiçada pelas PRV pode ser recuperada por bombas como turbinas (PAT). Entretanto, a seleção da bomba adequada ainda é um desafio, pois devem-se considerar as mudanças diárias de pressão e vazão dos consumidores (off-design). Neste artigo, uma combinação de modelos foi validada e aplicada para selecionar a bomba adequada para operar em uma WDN real. A substituição de duas PRV por PAT de uma rede real previamente dividida em duas DMA, operando em velocidade constante, foi investigada. As análises econômica e ambiental também foram efetuadas. A PAT1 foi tecnicamente melhor que PAT2, que apresentou pressão de saída negativa, prejudicando a pressão na DMA2. As melhores eficiências só ocorrem nas vazões no melhor ponto de eficiência da bomba ou próximo a ele, reproduzindo o controle da pressão como se fossem as próprias válvulas. A melhor bomba recuperou 4.331 kWh/ano, o equivalente à redução de 1.732.400 gCO2/ano, atendendo duas casas categorizadas como baixa renda. A utilização de PAT mostrou-se uma alternativa viável, com período de retorno de 2,1 anos, uma vez que é capaz de recuperar a energia renovável. Contudo, para o controle efetivo da pressão em WDN, devem-se buscar outras estratégias de operação, como a operação em velocidade variável.