Eunhye Kim

Dr. Eunhye Kim

Nagoya University, Nagoya, Aichi, Japan
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2011 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
EKEunhye Kim
Eunhye Kim
SLSeok-Won Lee
Seok-Won Lee
YLYong-Kwun Lee
Yong-Kwun Lee

24 May 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
EKEunhye Kim
Eunhye Kim
MKMasaru Kojima
Masaru Kojima
YMYasushi Mae
Yasushi Mae
TATATSUO ARAI
TATSUO ARAI
To assemble microobjects including biological cells quickly and precisely, a fully automated pick-and-place operation is applied. In micromanipulation in liquid, the challenges include strong adhesion forces and high dynamic viscosity. To solve these problems, a reliable manipulation system and special releasing techniques are indispensable. A microhand having dexterous motion is utilized to grasp an object stably, and an automated stage transports the object quickly. To detach the object adhered to one of the end effectors, two releasing methods—local stream and a dynamic releasing—are utilized. A system using vision-based techniques for the recognition of two fingertips and an object, as well automated releasing methods, can increase the manipulation speed to faster than 800 ms/sphere with a 100% success rate (N = 100). To extend this manipulation technique, 2D and 3D assembly that manipulates several objects is attained by compensating the positional error. Finally, we succeed in assembling 80–120 µm of microbeads and spheroids integrated by NIH3T3 cells.

1 April 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
TNTakuto Nomura
Takuto Nomura
MTMasaru Takeuchi
Masaru Takeuchi
EKEunhye Kim
Eunhye Kim
QHQiang Huang
Qiang Huang
Yasuhisa HasegawaYasuhisa Hasegawa
Yasuhisa Hasegawa
Toshio FukudaToshio Fukuda
Toshio Fukuda
In this article, we propose a new actuator named the modular bio-actuator (MBA). The MBA has two tendon structures made of polydimethylsiloxane (PDMS) at both ends of the bio-actuator. The MBA can be easily handled and fixed on an artificial micro-robot body to increase its design flexibility and output power. The tendon structures were connected to a bio-actuator in the form of a chain structure, and the connection between the tendon structures and the bio-actuator was maintained for more than three weeks. The contraction length of the MBA was linearly increased when the DC voltage applied to the MBA was increased. The MBA contracted over 200 µm when a DC voltage of 10 V and 1 Hz was applied to the bio-actuator. The output power of the MBA was measured using a PDMS cantilever, and the total output power of the MBA increased linearly when multiple MBAs were stacked on a PDMS cantilever. This study was aimed at improving the design flexibility and controllability of micro-robots and bionic systems.

31 December 2012 in Journal of the Korean Society for Applied Biological Chemistry
Verified
Journal Article
Open access
PDF file
EKEunhye Kim
Eunhye Kim
HLHyeri Lee
Hyeri Lee
SHSoonsung Hong
Soonsung Hong
KPKyung-Hun Park
Kyung-Hun Park
XAXuehua An
Xuehua An
JKJeong-Han Kim
Jeong-Han Kim
Operator exposure was evaluated to find out any possible risk during fenthion application in paddy. Hand exposure during mixing/loading was 0.04–33.06 mg, whereas those for spraying were 20.3–288.3 mg. Highest exposure was observed on legs (54%) followed by hand (28%). Inhalation exposure accounted for only 0.001–0.2% of dermal exposure. High variations of exposure levels were observed between repetitions and operators, indicating that lager number of repetitions are strictly required to establish comprehensive exposure database and predicting models. Margin of safety indicated that application works were safe when extreme cases were not considered.

1 September 2015
Verified
Conference Paper
Closed access
EKEunhye Kim
Eunhye Kim
MKMasaru Kojima
Masaru Kojima
KKKazuto Kamiyama
Kazuto Kamiyama
MHMitsuhiro Horade
Mitsuhiro Horade
YMYasushi Mae
Yasushi Mae
TATatsuo Arai
Tatsuo Arai
This paper presents an active release method of microobject for the improvement of the position accuracy after releasing by using 3D high speed motions of an end effector. In the micro manipulation, the release task is the challenge work due to adhesion forces. To overcome the adhesion force and to place microobject accurately on the desired location, in this paper, we propose a high speed motion by analyzing dynamic model of manipulated end effector and attached microbeads. Two fingered microhand driven by DC motors and PZT actuators is utilized for this paper. Parallel mecahnism with three PZT actuators was used for making 3D motion at high speed. To generatge high acceleration of end effector, many researchers applied simple vibration by using an additional PZT actuator. In our research, 3D high speed motion with large amplitude was achieved by only using a compacted parallel mechanism. To verify the advantage of the proposed motion, we compare five motions, 1D motions (X, Y, and Z direction) and circular motions (clockwise and counterclockwise direction), by changing the frequency and moving distance of the end effector. From these results of experiments, we conclude that the circular motion can detach microobjects with high placing accuracy after release.

Verified
Journal Article
Open access
PDF file
MTMasaru Takeuchi
Masaru Takeuchi
TKTaro Kozuka
Taro Kozuka
EKEunhye Kim
Eunhye Kim
AIAkihiko Ichikawa
Akihiko Ichikawa
Yasuhisa HasegawaYasuhisa Hasegawa
Yasuhisa Hasegawa
Toshio FukudaToshio Fukuda
Toshio Fukuda
We developed a procedure for fabricating movable biological cell structures using biodegradable materials on a microfluidic chip. A photo-cross-linkable biodegradable hydrogel gelatin methacrylate (GelMA) was used to fabricate arbitrary microstructure shapes under a microscope using patterned ultraviolet light. The GelMA microstructures were movable inside the microfluidic channel after applying a hydrophobic coating material. The fabricated microstructures were self-assembled inside the microfluidic chip using our method of fluid forcing. The synthesis procedure of GelMA was optimized by changing the dialysis temperature, which kept the GelMA at a suitable pH for cell culture. RLC-18 rat liver cells (Riken BioResource Research Center, Tsukuba, Japan) were cultured inside the GelMA and on the GelMA microstructures to check cell growth. The cells were then stretched for 1 day in the cell culture and grew well on the GelMA microstructures. However, they did not grow well inside the GelMA microstructures. The GelMA microstructures were partially dissolved after 4 days of cell culture because of their biodegradability after the cells were placed on the microstructures. The results indicated that the proposed procedure used to fabricate cell structures using GelMA can be used as a building block to assemble three-dimensional tissue-like cell structures in vitro inside microfluidic devices.