Federica Passeggio

Dr. Federica Passeggio

Ingegneria, Università degli Studi della Campania "L. Vanvitelli", Caserta, Campania, Italy
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
CMChiara Marzano
Chiara Marzano
RPRosalba Pitruzzella
Rosalba Pitruzzella
Francesco ArcadioFrancesco Arcadio
Francesco Arcadio
FPFederica Passeggio
Federica Passeggio
Mimimorena SeggioMimimorena Seggio
Mimimorena Seggio
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
Interleukins are involved in several diseases and cancers, and their detection and monitoring are of great interest. Their low abundance and short half-lives suggest the need to develop rapid, specific, and highly sensitive detection platforms, easily integrable in point-of-care (POC) systems. Among the other interleukins, interleukin IL-17A is associated with inflammations, neurodegenerative diseases, and cancers, and no biosensors have been previously reported for its detection. In this work, for the detection of IL-17A, a highly sensitive nanoplasmonic sensor based on natural nanostructures like pollen shells, covered by a gold film and a bio-receptor layer, is presented. Hybrid plasmonic modes are exploited to reach high sensitivity without using costly techniques to fabricate periodic nanostructures, such as electron beam lithography. A transparent amino-modified glass substrate is functionalized with carboxylic activated pollen via carbodiimide chemistry. Then, the pollen-based nanostructures are covered by a gold film and derivatized by an immuno-layer specific to IL-17A recognition. The developed IL-17A biosensor is monitored via a simple, small-sized, and low-cost experimental setup, demonstrating high selectivity, a fast response time of about five minutes, and sensitivity with a limit of detection in the ag/mL concentration range. The biosensor allows for the detection of IL-17A in complex solutions thanks to the possibility of high dilution, an advantageous aspect to POC systems.

14 May 2026 in Nanomaterials
Verified
Journal Article
Open access
PDF file
RPRosalba Pitruzzella
Rosalba Pitruzzella
DCDalila Cicatiello
Dalila Cicatiello
CMChiara Marzano
Chiara Marzano
FPFederica Passeggio
Federica Passeggio
LGLuca Gentile
Luca Gentile
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
Haemoglobin (Hb) concentration is a key biomarker for several diseases. Traditional laboratory methods often have limitations due to their time-consuming nature, the need for skilled personnel, or the use of high-cost instrumentation. This work presents a sensing strategy for developing new point-of-care tests (POCTs) for Hb detection via a proof of concept. The proposed sensing approach is implemented using plasmonic plastic optical fiber (POF) sensor chips that integrate an electropolymerized molecularly imprinted polymer (eMIP) film on the plasmonic surface for Hb-selective detection. The developed sensor system demonstrates an ultra-low detection limit of 80 fM in buffer, about five orders of magnitude lower than that of other comparable Hb sensors. Selectivity tests against common interfering proteins, such as bovine serum albumin (BSA) and immunoglobulin G (IgG), confirmed high specificity towards the target analyte. Moreover, the sensor’s performance was tested using a whole-blood sample, yielding results consistent with those of standard haematology analysis. The proposed sensor system, based on simple equipment, provides a quick (about 10 min) and cost-effective (about 10 euros per chip) label-free diagnostic tool for POCTs in real-world scenarios, such as finger-prick sampling, offering a less invasive alternative to traditional laboratory methods, towards devices useful for Internet of Medical Things (IoMT).

2 July 2024
Verified
Conference Paper
Closed access
ITInes Tavoletta
Ines Tavoletta
FAFrancesco Arcadio
Francesco Arcadio
LZLuigi Zeni
Luigi Zeni
MPMaria Pesavento
Maria Pesavento
GAGiancarla Alberti
Giancarla Alberti
NCNunzio Cennamo
Nunzio Cennamo
Glyphosate (GLY) contamination is a current problem that requires increasingly high-performance devices capable of detecting ultra-low concentrations of this difficult-to-monitor herbicide. For this reason, this study proposes an optical sensor based on unconventional surface plasmon resonance (SPR) phenomena, capable of detecting GLY concentrations at the nM level, exploiting the binding between the specific sites of a selective molecularly imprinted polymer (MIP) and GLY that occurs into the core of a modified plastic optical fiber (POF). Specifically, the MIP is located in a POF's micro-hole drilled upstream of the SPR region. Therefore, the samples are dropped into the MIP-filled micro-hole, while water is fixed on the SPR surface to excite the plasmonic phenomena. In this way, the interaction between the GLY and the MIP changes the refractive index in the POF core, and so do the SPR conditions downstream. The proposed configuration is based on a simple POF chip connected to a white light source and a spectrometer, obtaining an innovative platform with performances similar to those already present in the literature in terms of detection range, affinity constant (Kaff), and limit of detection (LOD).

8 July 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
Francesco ArcadioFrancesco Arcadio
Francesco Arcadio
ACAlessandro Capo
Alessandro Capo
Alessia CalabreseAlessia Calabrese
Alessia Calabrese
CMChiara Marzano
Chiara Marzano
Mimimorena SeggioMimimorena Seggio
Mimimorena Seggio
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
The Enterobacteriaceae family is a significant source of foodborne pathogens and represents a severe threat to human and animal health. These bacteria can penetrate the dairy supply chain through direct contact with cattle and the livestock environment and can survive production processes. Escherichia coli (E. coli), one of the most diffuse bacteria in raw and processed milk, exposes consumers to the risk of contaminated milk. As a result of this exposition, several milk-borne illness outbreaks have been reported worldwide, underscoring the urgent need for effective detection and prevention measures. Conventional analysis methods are effective but have significant limitations, including the requirement of pre-treatment and pre-enrichment steps. Thus, the need for advanced detection techniques that can accurately identify these pathogens without pre-treatment steps is critical. In this work, a proof-of-concept biosensor based on a spoon-shaped optical biochip was developed to detect E. coli via surface plasmon resonance (SPR) phenomena and was combined with a polyclonal antibody layer against E. coli as a molecular recognition element (MRE). The proposed label-free biosensing strategy, achieved by exploiting simple SPR spoon-shaped biochips, exhibits a remarkable detection limit (6.8 colony-forming units, CFU/mL) and high specificity towards other interfering bacteria belonging to the Enterobacteriaceae family. In addition, tests on commercial milk samples were carried out, achieving recovery values of 95% and 102% for whole milk and infant milk, respectively. The proposed spoon-shaped biosensor enables label-free biosensing without the need for microfluidic systems. It provides a rapid response (10 min), paving the way for its use as a point-of-care test (POCT) in real-world settings.