Francisco David Perez Reynoso

Dr. Francisco David Perez Reynoso

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
CCCésar Omar Capetillo Contreras
César Omar Capetillo Contreras
Francisco David Perez ReynosoFrancisco David Perez Reynoso
Francisco David Perez Reynoso
Marco Zamora AntuñanoMarco Zamora Antuñano
Marco Zamora Antuñano
José M. Álvarez-AlvaradoJosé M. Álvarez-Alvarado
José M. Álvarez-Alvarado
Juvenal RodriguezJuvenal Rodriguez
Juvenal Rodriguez
The world population is expected to grow to around 9 billion by 2050. The growing need for foods with high protein levels makes aquaculture one of the fastest-growing food industries in the world. Some challenges of fishing production are related to obsolete aquaculture techniques, overexploitation of marine species, and lack of water quality control. This research systematically analyzes aquaculture technologies, such as sensors, artificial intelligence (AI), and image processing. Through the systematic PRISMA process, 753 investigations published from 2012 to 2023 were analyzed based on a search in Scopus and Web of Science. It revealed a significant 70.5% increase in the number of articles published compared to the previous year, indicating a growing interest in this field. The results indicate that current aquaculture technologies are water monitoring sensors, AI methodologies such as K-means, and contour segmentation for computer vision. Also, it is reported that K means technologies offer an efficiency from 95% to 98%. These methods allow decisions based on data patterns and aquaculture insights. Improving aquaculture methodologies will allow adequate management of economic and environmental resources to promote fishing and satisfy nutritional needs.

31 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Francisco David Perez ReynosoFrancisco David Perez Reynoso
Francisco David Perez Reynoso
LRLiliam Rodríguez-Guerrero
Liliam Rodríguez-Guerrero
JSJulio César Salgado-Ramírez
Julio César Salgado-Ramírez
RORocío Ortega
Rocío Ortega
People with severe disabilities require assistance to perform their routine activities; a Human–Machine Interface (HMI) will allow them to activate devices that respond according to their needs. In this work, an HMI based on electrooculography (EOG) is presented, the instrumentation is placed on portable glasses that have the task of acquiring both horizontal and vertical EOG signals. The registration of each eye movement is identified by a class and categorized using the one hot encoding technique to test precision and sensitivity of different machine learning classification algorithms capable of identifying new data from the eye registration; the algorithm allows to discriminate blinks in order not to disturb the acquisition of the eyeball position commands. The implementation of the classifier consists of the control of a three-wheeled omnidirectional robot to validate the response of the interface. This work proposes the classification of signals in real time and the customization of the interface, minimizing the user’s learning curve. Preliminary results showed that it is possible to generate trajectories to control an omnidirectional robot to implement in the future assistance system to control position through gaze orientation.

12 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
Luis Alberto Gordillo RobleroLuis Alberto Gordillo Roblero
Luis Alberto Gordillo Roblero
JSJorge Alberto Soto-Cajiga
Jorge Alberto Soto-Cajiga
DDDaniela Diaz-Alonso
Daniela Diaz-Alonso
Francisco David Perez ReynosoFrancisco David Perez Reynoso
Francisco David Perez Reynoso
Hugo Jimenez HernandezHugo Jimenez Hernandez
Hugo Jimenez Hernandez
Numerous papers report the efficiency of the automatic interpretation capabilities of commercial algorithms. Unfortunately, these algorithms are proprietary, and academia has no means of directly contributing to these results. In fact, nothing at the same stage of development exists in academia. Despite the extensive research in ECG signal processing, from signal conditioning to expert systems, a cohesive single application for clinical use is not ready yet. This is due to a serious lack of coordination in the academic efforts, which involve not only algorithms for signal processing, but also the signal acquisition equipment itself. For instance, the different sampling rates and the different noise levels frequently found in the available signal databases can cause severe incompatibility problems when the integration of different algorithms is desired. Therefore, this work aims to solve this incompatibility problem by providing the academic community with a diagnostic-grade electrocardiograph. The intention is to create a new standardized ECG signals database in order to address the automatic interpretation problem and create an electrocardiography system that can fully assist clinical practitioners, as the proprietary systems do. Achieving this objective is expected through an open and coordinated collaboration platform for which a webpage has already been created.


9 December 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Francisco David Perez ReynosoFrancisco David Perez Reynoso
Francisco David Perez Reynoso
JSJorge Alberto Soto-Cajiga
Jorge Alberto Soto-Cajiga
Luis Alberto Gordillo RobleroLuis Alberto Gordillo Roblero
Luis Alberto Gordillo Roblero
PSPaola Andrea Niño Suarez
Paola Andrea Niño Suarez
This study presents an open and replicable methodology for multi-lead ECG signal quality assessment (SQA), implemented on a 12-lead embedded acquisition platform. Signal quality is a critical software component for diagnostic reliability and compliance with international standards such as IEC 60601-2-27 (clinical ECG monitors), IEC 60601-2-47 (ambulatory ECG systems), and IEC 62304 (software life cycle for medical devices) which define the essential engineering requirements and functional performance for medical devices. Unlike proprietary SQA algorithms embedded in closed commercial systems such as Philips DXL™, the proposed method provides a transparent and auditable framework that enables independent validation and supports adaptation for research and clinical prototyping. Our approach combines convolutional neural networks (CNNs) with FFT-derived spectrograms to perform four-level signal quality classification (High, Medium, Low, and Unidentifiable), achieving up to 95.67% accuracy on the test set, confirming the robustness of the CNN-based spectrogram classification model. The algorithm has been validated on a custom controlled dataset generated using the Fluke PS420™ hardware simulator, enabling controlled replication of signal artifacts for software-level evaluation. Designed for execution on resource-constrained embedded platforms, the system integrates real-time preprocessing and wireless transmission, demonstrating its feasibility for deployment in mobile or decentralized ECG monitoring solutions. These results establish a software validation proof-of-concept that goes beyond algorithmic performance, addressing regulatory expectations such as those outlined in FDA’s Good Machine Learning Practice (GMLP). While clinical validation remains pending, this work contributes a standards-aligned methodology to democratize advanced SQA functionality and support future regulatory-compliant development of embedded ECG system.

15 July 2026 in Algorithms
Verified
Journal Article
Open access
PDF file
LGLester Fitz Gama
Lester Fitz Gama
Juvenal RodriguezJuvenal Rodriguez
Juvenal Rodriguez
Francisco David Perez ReynosoFrancisco David Perez Reynoso
Francisco David Perez Reynoso
CCCésar Omar Capetillo Contreras
César Omar Capetillo Contreras
Luis Alberto Gordillo RobleroLuis Alberto Gordillo Roblero
Luis Alberto Gordillo Roblero
Surface electromyography (sEMG) is widely used to evaluate neuromuscular activity; however, objective and reproducible methodologies for assessing signal quality in embedded acquisition systems remain limited. This study presents a multichannel embedded sEMG acquisition platform based on an ADS1298 analog front-end (Texas Instruments, Dallas, TX, USA) and an STM32H743ZIT6 microcontroller (STMicroelectronics, Geneva, Switzerland), together with a signal-quality evaluation methodology guided by signal-integrity principles derived from IEC 60601-2-40. sEMG signals were acquired at 2 kHz from 10 healthy participants during standardized submaximal isometric and controlled isotonic contractions using consistent electrode placement and acquisition procedures. Signal quality was quantified using complementary temporal and spectral metrics, including signal-to-noise ratio (SNR), power-line interference ratio (PLI), baseline drift, root mean square stability, median frequency, spectral entropy, skewness, and kurtosis. Signal conditioning reduced the baseline drift from 0.32 ± 0.23 to 0.004 ± 0.003 and reduced PLI from 0.097 ± 0.135 to 0.010 ± 0.003 while preserving contraction-dependent temporal and spectral characteristics. In addition, envelope-based Spearman correlation analysis revealed contraction-dependent intermuscular coordination patterns between the long and short heads of the biceps brachii under controlled acquisition conditions. These findings demonstrate that combining standardized acquisition protocols, objective signal quality metrics, and interpretable correlation-based analysis provides a reproducible engineering framework for evaluating embedded sEMG systems and establishes a foundation for future machine learning approaches based on larger and well-characterized physiological datasets.