Giovany Orozco-Hernández

Prof. Dr. Giovany Orozco-Hernández

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2024 in Metals
Verified
Journal Article
Open access
PDF file
William AperadorWilliam Aperador
William Aperador
JAJonnathan Aperador
Jonnathan Aperador
Giovany Orozco-HernándezGiovany Orozco-Hernández
Giovany Orozco-Hernández
This study presents a comparative analysis of the corrosion and mechanical properties of an Al-SiC composite and an AA 2024 aluminum alloy, focusing on their suitability for aeronautical applications. The Al-SiC composite was fabricated using advanced powder metallurgy techniques, incorporating a 20% volume of silicon carbide (SiC) particles, averaging 1.6 µm in size, to enhance its structural and electrochemical performance. Electrochemical evaluations in an aerated 3.5% NaCl solution revealed a significant improvement in the corrosion resistance of the Al-SiC composite. This enhancement is attributed to the cathodic nature of the SiC particles, which promote the formation of a protective aluminum oxide layer, reducing pitting corrosion and preserving the material’s structural integrity. In terms of the mechanical properties, the Al-SiC composite demonstrated a higher yield strength and ultimate tensile strength compared to the AA 2024 alloy. While it exhibited a slightly lower elongation at failure, the composite maintained a favorable balance between strength and ductility. Additionally, the composite showed a higher Young’s modulus indicating improved resistance to deformation under load. These findings underscore the potential of the Al-SiC composite for demanding aerospace applications, offering valuable insights into the development of materials capable of withstanding extreme operational environments.

2 January 2023 in Revista Científica
Verified
Journal Article
Open access
PDF file
LTLUIS CARLOS ARDILA TELLEZ
LUIS CARLOS ARDILA TELLEZ
Giovany Orozco-HernándezGiovany Orozco-Hernández
Giovany Orozco-Hernández
FEFredy Estupiñan-Mongui
Fredy Estupiñan-Mongui
CMCarlos-Mauricio Moreno-Téllez
Carlos-Mauricio Moreno-Téllez
JOJhon Jairo Olaya
Jhon Jairo Olaya
The success of a functional coating is intrinsically linked to the improvement of its surface properties, as it is the surface that will be in direct contact with the environment and mechanical stresses when the material is used in severe wear, fatigue, or corrosion applications. It has been shown, for example, by increasing mechanical properties, that factors such as surface hardness increase the durability of the coating/substrate system. Consequently, current research on the design and development of multifunctional coatings for surface engineering within mechanical systems must address surface treatment and modification techniques. This article is a bibliographic review of coatings with industrial applications regarding transition metal nitrides deposited with physical vapor deposition (PVD) techniques such as sputtering and cathodic arc.

1 May 2021 in Lubricants
Verified
Journal Article
Open access
PDF file
Giovany Orozco-HernándezGiovany Orozco-Hernández
Giovany Orozco-Hernández
PGPablo Guzman
Pablo Guzman
William AperadorWilliam Aperador
William Aperador
Materials used in biomedicine for purposes of long-time stay inside the body presents diverse sort of problems like cytotoxicity, wear, biocompatibility, and ion liberation along time. This paper presents the characterization of corrosion-wear combined phenomena on Nb2O5, TiO2, and Nb2O5 + TiO2 coatings with future applications as biomaterials. After the films’ production process using magnetron sputtering technique, they were characterized through an optic, scanning electron, and atomic force microscopy to evaluate their morphology, structure, and surface damage suffered by the synergy between wear and corrosion phenomena. The life in service of the implant was evaluated in terms of the coating behavior against inside body conditions like charge, wear, and electrochemical degradation. This test was made with electrochemical measurements in simulated biological fluid combined with the wear characterization implementing a potentiostat and a tribometer in a linear wear configuration with a bone pin. As a result, the different electrochemical responses of the films were evidenced by polarization curves and equivalent circuits of the systems. The coefficient of friction and surface degradation were also obtained and evaluated. Comparing the properties of the systems, we conclude that TiO2 coatings have better behavior in terms of the wear-corrosion synergy phenomena while the systems with Nb present pitting corrosion.

22 July 2025 in Coatings
Verified
Journal Article
Open access
PDF file
William AperadorWilliam Aperador
William Aperador
Giovany Orozco-HernándezGiovany Orozco-Hernández
Giovany Orozco-Hernández
This study investigates the development of silver (Ag)-doped zirconia (ZrO2) coatings deposited on 316LVM stainless steel via the unbalanced magnetron sputtering technique. The oxygen content in the Ar/O2 gas mixture was systematically varied (12.5%, 25%, 37.5%, and 50%) to assess its influence on the resulting coating properties. In response to the growing demand for biomedical implants with improved durability and biocompatibility, the objective was to develop coatings that enhance both wear and corrosion resistance in physiological environments. The effects of silver incorporation and oxygen concentration on the structural, tribological, and electrochemical behavior of the coatings were systematically analyzed. X-ray diffraction (XRD) was employed to identify crystalline phases, while atomic force microscopy (AFM) was used to characterize surface topography prior to wear testing. Wear resistance was evaluated using a ball-on-plane tribometer under simulated prosthetic motion, applying a 5 N load with a bone pin as the counter body. Corrosion resistance was assessed through electrochemical impedance spectroscopy (EIS) in a physiological solution. Additionally, tribocorrosive performance was investigated by coupling tribological and electrochemical tests in Ringer’s lactate solution, simulating dynamic in vivo contact conditions. The results demonstrate that Ag doping, combined with increased oxygen content in the sputtering atmosphere, significantly improves both wear and corrosion resistance. Notably, the ZrO2-Ag coating deposited with 50% O2 exhibited the lowest wear volume (0.086 mm3) and a minimum coefficient of friction (0.0043) under a 5 N load. This same coating also displayed superior electrochemical performance, with the highest charge transfer resistance (38.83 kΩ·cm2) and the lowest corrosion current density (3.32 × 10−8 A/cm2). These findings confirm the high structural integrity and outstanding tribocorrosive behavior of the coating, highlighting its potential for application in biomedical implant technology.

7 December 2023 in Crystals
Verified
Journal Article
Open access
PDF file
LTLUIS CARLOS ARDILA TELLEZ
LUIS CARLOS ARDILA TELLEZ
RDR. Dueñas
R. Dueñas
Giovany Orozco-HernándezGiovany Orozco-Hernández
Giovany Orozco-Hernández
JOJhon Jairo Olaya
Jhon Jairo Olaya
AJAndrés Felipe Ordóñez Jiménez
Andrés Felipe Ordóñez Jiménez
YTYaneth Pineda Triana
Yaneth Pineda Triana
In this work, nanostructured TiAlCrN coatings were deposited on a WC-Co substrate using a co-sputtering process varying the silicon composition on the coatings. The influence of silicon content on the mechanical, chemical, and tribological performance of the coatings was studied. The hardness increases from 11 to 16 GPa with the Si content; also, Young’s modulus increases from 260 to 295 GPa. The H/E ratio, which is a measure of materials’ ability to take the strain before deformation, is also increased with the increase in Si content, suggesting increased toughness. XPS analysis reveals that the coatings present titanium, aluminum, chromium, and silicon nitrides. The tribological behavior of the coatings was conducted through ball-on-disc tests, in which the results show that the coefficients of friction range from 0.15 to 0.55, with the lowest for the samples with the highest Si content. This behavior is benefited by the formation of oxynitride species, identified by XPS, which acts as lubricating layers and diffusion barriers. TiAlCrSixN coating presents a potential application for severe wear owing to its tribological performance.

8 October 2024 in Metals
Verified
Journal Article
Open access
PDF file
Giovany Orozco-HernándezGiovany Orozco-Hernández
Giovany Orozco-Hernández
SMSara valentina Mosquera
Sara valentina Mosquera
JMJuliana Valeria Ramírez Monroy
Juliana Valeria Ramírez Monroy
William AperadorWilliam Aperador
William Aperador
ACAdriana Patricia Corredor-Figueroa
Adriana Patricia Corredor-Figueroa
YTYaneth Pineda Triana
Yaneth Pineda Triana
Titanium alloys, particularly Ti6Al4V, are widely used in biomedical applications due to their excellent mechanical properties and inherent biocompatibility. However, enhancing their surface characteristics, such as biocompatibility and corrosion resistance, remains a key challenge for their long-term use in medical implants. In this study, we investigate the effects of rhenium–carbon coatings deposited on Ti6Al4V substrates via magnetron sputtering, incorporating a molybdenum anchoring layer. X-ray diffraction (XRD) and energy dispersive spectroscopy (EDS) analyses confirmed the formation of rhenium carbides, elemental rhenium, and rhenium oxides within the coatings. Despite these successful depositions, scanning electron microscopy (SEM) revealed significant delamination and poor adhesion of the coatings to the Ti6Al4V substrates. Corrosion resistance, evaluated through potentiodynamic polarization tests, showed an increase in corrosion current densities and more negative corrosion potentials, indicating a detrimental effect on the substrate’s corrosion resistance. Biocompatibility assessments using PK15 cells demonstrated a marked decrease in cell viability and metabolic activity, particularly in samples with higher surface roughness. These findings underscore the critical need for the optimization of surface preparation and deposition processes to improve both the adhesion and biocompatibility of rhenium–carbon coatings on Ti6Al4V substrates. Future research should aim to refine coating technique to enhance adhesion, explore the mechanisms of cytotoxicity related to surface roughness, and expand biocompatibility studies across different cell lines and biological environments.