Gulmira Iskakova

Ms. Gulmira Iskakova

Automation and Control, Almaty University of Power Engineering and Telecommunications, Almaty, Kazakhstan

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2024 in Вестник КазАТК
Verified
Journal Article
Open access
PDF file
GBGulmira D. Bazil
Gulmira D. Bazil
LALaulassyn Abzhanova
Laulassyn Abzhanova
GIGulmira Iskakova
Gulmira Iskakova
ШСШолпан Сагындыкова
Шолпан Сагындыкова
КИКурмангазы Исламқұлыев
Курмангазы Исламқұлыев
В работе представлен лабораторный стенд исследования и моделирования процессов теплообмена, разработанный и собранный кафедрой «Автоматизации и управления». Работа «Разработка программной части лабораторного стенда системы управления теплоснабжением на базе PLC B&R» является успешно завершенным проектом. Разработанное программное обеспечение позволяет эффективно управлять процессами теплообмена на лабораторном стенде. В ходе работы были изучены основы теплообмена, выбраны и использованы программно-логические контроллеры PLC B&R, разработаны алгоритмы оптимизации и отрегулированы параметры системы. Разработанная система была успешно протестирована и показала положительные результаты в области производительности. Результаты работ могут быть использованы для улучшения реальных систем теплоснабжения.

15 November 2023 in Вестник КазАТК
Verified
Journal Article
Open access
PDF file
GBGulmira D. Bazil
Gulmira D. Bazil
АЕАнаргуль Ербосынова
Анаргуль Ербосынова
LALaulassyn Abzhanova
Laulassyn Abzhanova
ШАШынар Адилова
Шынар Адилова
GIGulmira Iskakova
Gulmira Iskakova
В работе рассмотрены вопросы исследования, моделирования и создания систем автоматического управления теплообменными процессами. Модель системы отопления помещения была реализована в среде программирования Matlab. При моделировании в качестве основных технологических параметров принимались коэффициент теплообмена и расход жидкости в теплообменнике. Предполагается, что полученная модель будет использоваться при моделировании процессов теплообмена с использованием данных, полученных на лабораторном стенде «Моделирование процессов теплообмена».

28 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LALaulassyn Abzhanova
Laulassyn Abzhanova
AAAkerke Absatarova
Akerke Absatarova
Svetlana KhanSvetlana Khan
Svetlana Khan
GIGulmira Iskakova
Gulmira Iskakova
Larisa RudakovaLarisa Rudakova
Larisa Rudakova
LSLaura Sugurova
Laura Sugurova
This paper presents a simulation-based feasibility study of nonlinear model predictive control (NMPC) for process water quality management in the closed-loop water circuit of the Aktogai copper concentrator. Repeated water recirculation leads to the accumulation of total dissolved solids (TDSs), organic compounds (CODs), and suspended solids (TSSs), degrading flotation efficiency. A dynamic model of the process water pond with nine flows is combined with pseudo-first-order kinetics for H2O2 oxidation (kox = 0.003 L/(mg·h)) and polyaluminum chloride (PAC)/FeCl3 coagulation (kcoag = 0.005 L/(mg·h)). The NMPC manipulates the treated-effluent flow Q2 and the coagulant and oxidant doses over an 8 h prediction horizon, uses normalized one-sided soft constraints on water quality and a reagent cost, and is solved through sequential quadratic programming. The volume, TDSs, and TSSs are assumed to be measured online, whereas CODs are available only from laboratory analyses taken every 2–8 h with a 2 h delay. NMPC was compared with no-control, fixed dosing, a maximum-dilution policy, and a proportional–integral (PI) feedback dosing benchmark with the same manipulated variables. Under nominal disturbances, all strategies met the process limits. Under a simulated stress-test scenario (ore change and reagent overdosing), no control produced 26, 37, and 25 h of TDS, COD, and TSS violations in 72 h; maximum dilution alone removed the TDS and TSS violations but left 13 h of COD violations. With online measurements, a well-tuned PI controller performed almost as well as NMPC (1 h vs. 0 h of COD violations). With laboratory COD analyses, the PI controller incurred 4–11 h of COD violations, whereas NMPC, using a model-based COD estimate between analyses, incurred none, at the cost of 9–47% higher oxidant consumption; this advantage reflects the combined effect of model-based COD estimation and predictive optimization, not of predictive optimization alone. It persisted under up to 30% adverse parametric plant–model mismatch, and the results were insensitive to tenfold variations in the selected NMPC tuning weights. TDSs could be held below their limit only through hydraulic dilution and only while the thickener-overflow TDSs remained below about 2260 mg/L.

13 February 2025 in Вестник КазАТК
Verified
Journal Article
Open access
PDF file
GBGulmira D. Bazil
Gulmira D. Bazil
АААйнэлла Аркалықова
Айнэлла Аркалықова
GIGulmira Iskakova
Gulmira Iskakova
Жұмыстың мақсаты орталықтандырылған жылумен жабдықтау жүйелеріндегі сенімділікті, энергия тиімділігін арттыру және пайдалану процестерін оңтайландыру үшін тиімділіктің негізгі көрсеткіштеріне негізделген жылумен жабдықтауды басқару жүйесін әзірлеу болып табылады. Методология. Жұмыста жылумен жабдықтау жүйесінің құрылымын зерттеу және талдау үшін графтар әдісі қолданылды. Бұл тәсіл жүйенің графикалық моделін құруға, негізгі түйіндер мен байланыстарды анықтауға және басқару тиімділігіне әсер ететін ең маңызды коэффициенттерді анықтауға мүмкіндік берді. Коэффициенттердің маңыздылығын талдау графиктің шыңдары мен шеттерін салмақтық бағалау әдістерін қолдана отырып жүргізілді, бұл факторларды саралау және оларды оңтайландыру үшін ұсыныстар қалыптастыру мүмкіндігін қамтамасыз етті. Алынған мәліметтер жылумен жабдықтау жүйесінің энергия тиімділігі мен сенімділігін арттыруға бағытталған басқару алгоритмдерін жасау үшін пайдаланылды. Негізгі нәтижелер. Тиімділіктің негізгі көрсеткіштерін (KPI) талдауға негізделген жылумен жабдықтау жүйесін басқарудың графикалық моделі жасалды. Графикалық теория әдістерін қолдана отырып, сенімділік пен энергия тиімділігін анықтайтын жүйенің маңызды коэффициенттері анықталды. Графикалық байланыстарды визуализациялау және түсіндіру арқылы жылумен жабдықтау жүйесінің құрылымына егжей-тегжейлі талдау жүргізілді, бұл жалпы тиімділікке ең көп әсер ететін түйіндерді анықтауға мүмкіндік берді. Коэффициенттер мен байланыстардың әсерін бағалау үшін график элементтерін салмақ дәрежесі әдісі қолданылады. Алынған нәтижелер зерттелетін жылумен жабдықтау жүйесінің құрылымдық және пайдалану сипаттамаларының ерекшеліктеріне бейімделген басқару алгоритмдерінің негізін құрады. Негізгі тұжырымдар. Ұсынылған жылумен жабдықтауды басқарудың графикалық моделі сенімділік пен энергия тиімділігіне әсер ететін негізгі коэффициенттерді анықтауға мүмкіндік беретін жүйені талдау мен оңтайландырудың тиімді құралы болып табылады. Графикалық әдісті қолдану жүйенің құрылымын модельдеуде жоғары дәлдік пен бейімделуді қамтамасыз етеді, сонымен қатар жылу ағындарын басқаруды жақсартуға және пайдалану тәуекелдерін азайтуға көмектеседі.