Akerke Absatarova

Ms. Akerke Absatarova

orcid

Research Focus & Metrics

Representative Publications

View All Publications
28 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LALaulassyn Abzhanova
Laulassyn Abzhanova
AAAkerke Absatarova
Akerke Absatarova
Svetlana KhanSvetlana Khan
Svetlana Khan
GIGulmira Iskakova
Gulmira Iskakova
Larisa RudakovaLarisa Rudakova
Larisa Rudakova
LSLaura Sugurova
Laura Sugurova
This paper presents a simulation-based feasibility study of nonlinear model predictive control (NMPC) for process water quality management in the closed-loop water circuit of the Aktogai copper concentrator. Repeated water recirculation leads to the accumulation of total dissolved solids (TDSs), organic compounds (CODs), and suspended solids (TSSs), degrading flotation efficiency. A dynamic model of the process water pond with nine flows is combined with pseudo-first-order kinetics for H2O2 oxidation (kox = 0.003 L/(mg·h)) and polyaluminum chloride (PAC)/FeCl3 coagulation (kcoag = 0.005 L/(mg·h)). The NMPC manipulates the treated-effluent flow Q2 and the coagulant and oxidant doses over an 8 h prediction horizon, uses normalized one-sided soft constraints on water quality and a reagent cost, and is solved through sequential quadratic programming. The volume, TDSs, and TSSs are assumed to be measured online, whereas CODs are available only from laboratory analyses taken every 2–8 h with a 2 h delay. NMPC was compared with no-control, fixed dosing, a maximum-dilution policy, and a proportional–integral (PI) feedback dosing benchmark with the same manipulated variables. Under nominal disturbances, all strategies met the process limits. Under a simulated stress-test scenario (ore change and reagent overdosing), no control produced 26, 37, and 25 h of TDS, COD, and TSS violations in 72 h; maximum dilution alone removed the TDS and TSS violations but left 13 h of COD violations. With online measurements, a well-tuned PI controller performed almost as well as NMPC (1 h vs. 0 h of COD violations). With laboratory COD analyses, the PI controller incurred 4–11 h of COD violations, whereas NMPC, using a model-based COD estimate between analyses, incurred none, at the cost of 9–47% higher oxidant consumption; this advantage reflects the combined effect of model-based COD estimation and predictive optimization, not of predictive optimization alone. It persisted under up to 30% adverse parametric plant–model mismatch, and the results were insensitive to tenfold variations in the selected NMPC tuning weights. TDSs could be held below their limit only through hydraulic dilution and only while the thickener-overflow TDSs remained below about 2260 mg/L.

30 September 2025 in Bulletin of Shakarim University. Technical Sciences
Verified
Journal Article
Open access
PDF file
ETE. S. Talmurzin
E. S. Talmurzin
GBGulmira D. Bazil
Gulmira D. Bazil
AAAkerke Absatarova
Akerke Absatarova
EOE. Zh. Orakbayev
E. Zh. Orakbayev
YOYerbol Ospanov
Yerbol Ospanov
This paper deals with the automation of biological water treatment system using fuzzy logic. The main objective of the work is to develop a fuzzy controller capable of adapting to the changing conditions of the purification process. The implementation of fuzzy logic can improve the control efficiency by considering many factors affecting the purification process. The paper proposes fuzzy control rules for optimising the operation of pumps, aeration systems and reagent supply, as well as methods for their implementation.Methodology: The methodology includes analysis of existing cleaning methods, development of a fuzzy control system, its modelling and experimental validation. First, current technologies and their potential for automation are investigated. Then fuzzy control rules are developed based on expert data and mathematical models. Next, the system is modelled to verify the performance and at the end it is experimentally tested on laboratory or production units.Main results: An automated control system for biological water treatment based on fuzzy logic has been developed to adapt to changes in environmental parameters. Modelling of the system operation confirmed its ability to properly regulate the operation of pumps, aeration systems and reagent supply. Experimental studies have shown that the use of fuzzy logic helps to increase the stability of the purification process.