Harshitha Monali Adrija

Ms. Harshitha Monali Adrija

Image Processing Laboratory, South Dakota State University, Brookings, Oregon, USA
orcid
Ph.D. student @ South Dakota State University | MS in Electr...

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Remote Sensing
Verified
Journal Article
Open access
PDF file
JRJuliana Fajardo Rueda
Juliana Fajardo Rueda
LLLarry Leigh
Larry Leigh
MKMorakot Kaewmanee
Morakot Kaewmanee
HAHarshitha Monali Adrija
Harshitha Monali Adrija
CPCibele Teixeira Pinto
Cibele Teixeira Pinto
This study presents the selection of 20 Extended Pseudo Invariant Calibration Sites (EPICS) for radiometric calibration and the derivation of their hyperspectral profiles using the DLR Earth Sensing Imaging Spectrometer (DESIS) and Hyperion data. The hyperspectral profile of one of these clusters, the GONA-EPICS cluster, was validated against ground truth measurements from the RadCalNet Gobabeb Namibia (GONA) site, demonstrating statistical agreement within their respective uncertainties through Welch’s test. The applicability of these hyperspectral profiles was further evaluated by generating Spectral Band Adjustment Factor (SBAF) between Landsat 8 and Sentinel-2A using the GONA-EPICS hyperspectral profile and comparing them to SBAF values derived from RadCalNet GONA site measurements. SBAF results were statistically the same, while SBAF derived from the combined DESIS and Hyperion data exhibited reduced uncertainty compared to those derived using Hyperion data alone, which is attributed to DESIS’s finer spectral resolution (2.5 nm vs. 10 nm). To assess EPICS applicability in cross-calibration, Cluster 13-GTS, which includes pixels from the Libya 4 CNES ROI, was used as a target. Cross-calibration gains obtained using EPICS and the T2T cross-calibration methodology were compared to those from the traditional cross-calibration approach using Libya 4 CNES ROI. Results demonstrated statistically similar gains, with EPICS achieving an uncertainty better than 6% across all bands compared to 4.4% for the traditional method, while enabling global coverage for daily cross-calibration opportunities. This study introduces globally distributed EPICS with validated hyperspectral profiles, offering enhanced spectral resolution and reliability for radiometric calibration and stability monitoring. The methodology supports efficient global scale sensor calibration and prepares for future hyperspectral missions.

5 April 2025 in Remote Sensing
Verified
Journal Article
Open access
PDF file
HAHarshitha Monali Adrija
Harshitha Monali Adrija
LLLarry Leigh
Larry Leigh
MKMorakot Kaewmanee
Morakot Kaewmanee
DPDinithi Siriwardana Pathiranage
Dinithi Siriwardana Pathiranage
JRJuliana Maria Fajardo Rueda
Juliana Maria Fajardo Rueda
CPCibele Teixeira Pinto
Cibele Teixeira Pinto
This study addresses the critical need for radiometrically accurate and consistent hyperspectral data as the remote sensing community moves towards a hyperspectral world. Previous calibration efforts on Hyperion, the first on-orbit hyperspectral sensors, have exhibited temporal stability and absolute accuracy limitations. This work has developed and validated a novel cross-calibration methodology to address these challenges. Also, this work adds two other hyperspectral sensors, DLR Earth Sensing Imaging Spectrometer (DESIS) and Earth Surface mineral Dust Source Investigation instrument (EMIT), to maintain temporal continuity and enhance spatial coverage along with spectral resolution. The study established a robust approach for calibrating Hyperion using DESIS and EMIT. The methodology involves several key processes. First is a temporal stability assessment on Extended Pseudo Invariant Calibration Sites (EPICS) Cluster13–Global Temporal Stable (GTS) over North Africa (Cluster13–GTS) using Landsat Sensors Landsat 7 (ETM+), Landsat 8 (OLI). Second, a temporal trend correction model was developed for DESIS and Hyperion using statistically selected models. Third, absolute calibration was developed for DESIS and EMIT using multiple vicarious calibration sites, resulting in an overall absolute calibration uncertainty of 2.7–5.4% across the DESIS spectrum and 3.1–6% on non-absorption bands for EMIT. Finally, Hyperion was cross-calibrated using calibrated DESIS and EMIT as reference (with traceability to ground reference) with a calibration uncertainty within the range of 7.9–12.9% across non-absorption bands. The study also validates these calibration coefficients using OLI over Cluster13–GTS. The validation provided results suggesting a statistical similarity between the absolute calibrated hyperspectral sensors mean TOA (top-of-atmosphere) reflectance with that of OLI. This study offers a valuable contribution to the community by fulfilling the above-mentioned needs, enabling more reliable intercomparison, and combining multiple hyperspectral datasets for various applications.