Hanan Al-Johani

Dr. Hanan Al-Johani

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
Hanan Al-JohaniHanan Al-Johani
Hanan Al-Johani
Julfikar HaiderJulfikar Haider
Julfikar Haider
JSJulian David Satterthwaite
Julian David Satterthwaite
Nikolaos SilikasNikolaos Silikas
Nikolaos Silikas
Considering the rapid evolution of lithium silicate-based glass ceramics (LSCs) in dentistry, this review paper aims to present an updated overview of the recently introduced commercial novel LSCs. The clinical and in vitro English-language literature relating to the microstructure, manufacturing, strengthening, properties, surface treatments and clinical performance of LSC materials was obtained through an electronic search. Findings from relevant articles were extracted and summarised for this manuscript. There is considerable evidence supporting the mechanical and aesthetic competency of LSC variants, namely zirconia-reinforced lithium silicates and lithium–aluminium disilicates. Nonetheless, the literature assessing the biocompatibility and cytotoxicity of novel LSCs is scarce. An exploration of the chemical, mechanical and chemo-mechanical intaglio surface treatments—alternative to hydrofluoric acid etching—revealed promising adhesion performance for acid neutralisation and plasma treatment. The subtractive manufacturing methods of partially crystallised and fully crystallised LSC blocks and the additive manufacturing modalities pertaining to the fabrication of LSC dental restorations are addressed, wherein that challenges that could be encountered upon implementing novel additive manufacturing approaches using LSC print materials are highlighted. Furthermore, the short-term clinical performance of zirconia-reinforced lithium silicates and lithium–aluminium disilicates is demonstrated to be comparable to that of lithium disilicate ceramics and reveals promising potential for their long-term clinical performance.

19 January 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
Hanan Al-JohaniHanan Al-Johani
Hanan Al-Johani
JHJulfikar Haider
Julfikar Haider
Nikolaos SilikasNikolaos Silikas
Nikolaos Silikas
JSJulian David Satterthwaite
Julian David Satterthwaite
The influence of different firing protocols on the topographical, optical, and mechanical properties of fully crystallized computer-aided design and computer-aided manufacturing (CAD-CAM) lithium silicate-based glass-ceramics (LSCs) for dental restorations remains unclear. The purpose of this in vitro study was to investigate the effect of different firing regimens on the surface roughness, gloss, Martens hardness, indentation modulus, biaxial flexural strength, and crystalline structure of fully crystallized CAD-CAM LSCs and the effect of their interposition on the irradiance of a light-polymerization unit. Three fully crystallized CAD-CAM LSC blocks were evaluated (N=150): lithium disilicate (Initial LiSi Blocks; LS), zirconia-reinforced silicate (Celtra Duo; CD), and lithium aluminum disilicate (CEREC Tessera; CT). Specimens were allocated to 5 subgroups according to their firing protocol. LSC roughness (Sa) was measured with an optical profilometer, and gloss (GU) was detected with a gloss meter. Martens hardness (HM) and indentation modulus (EIT) data were obtained from a hardness testing machine. The irradiance of a light-polymerization unit and transmittance of LSCs were measured with an instrument (Managing Accurate Resin Curing-Light Collector; BlueLight analytics, Inc) subsequent to ceramic interposition. Crystalline phases were analyzed by X-ray diffraction, and biaxial flexural strength (σ) was determined by the ball-on-3-ball method in a universal testing machine followed by Weibull analysis to calculate characteristic strength (σ0) and Weibull modulus (m). Two-way ANOVA and Tukey HSD post hoc tests (α=.05) were used to analyze the data. Statistically significant differences were found among different treatment groups based on Sa, GU, HM, and EIT values (P<.001). Delivered irradiance was significantly reduced following CT (P<.01) and glazed LSC (P<.005) interposition. CD displayed highest biaxial flexural strength and reliability after 1 firing cycle (σ=568.2 MPa, m=16.8) CONCLUSIONS: The type of material and firing regimens had a significant effect on the topographical, optical, and mechanical properties of fully crystallized CAD-CAM LSCs. Glazing significantly reduced delivered irradiance, Martens hardness, and biaxial flexural strength.

2 April 2025 in Journal of Dentistry
Verified
Journal Article
Open access
PAPinar Altinci
Pinar Altinci
MDMustafa Borga Donmez
Mustafa Borga Donmez
GÇGülce Çakmak
Gülce Çakmak
Hanan Al-JohaniHanan Al-Johani
Hanan Al-Johani
ÇKÇiğdem Kahveci
Çiğdem Kahveci
BYBurak Yilmaz
Burak Yilmaz
To evaluate the effects of margin configuration and pulp chamber depth on the fabrication trueness and internal fit of resin-based endocrowns fabricated with additive (AM) and subtractive manufacturing (SM). Four mandibular first molar typodonts prepared with butt joint or 1 mm-wide shoulder margins and 2 mm or 4 mm pulp chamber depths were digitized to design reference endocrowns. These designs were used to fabricate endocrowns with AM (Crowntec [AM-CT], FREEPRINT Crown [AM-FP], Tera Harz TC80DP [AM-GR]) or SM (Tetric CAD [SM-TC]) (n = 7). Surface deviations (external, intaglio, and marginal root mean square, RMS) and triple scan protocol (average gap) were used for digital analyses. Data were analyzed with generalized linear models (α = 0.05). Intaglio RMS was affected by the interaction of all main factors, while all surface deviations were affected by material type-margin configuration interaction. Material type-pulp chamber depth interaction affected intaglio RMS and average gaps, whereas margin configuration-pulp chamber depth interaction affected all outcomes, except intaglio RMS (P ≤ 0.001). AM-GR mostly led to lower intaglio and marginal RMS, while SM-TC mostly led to lower external RMS (P ≤ 0.022). SM-TC endocrowns with 4-mm depth had the highest and AM-GR endocrowns with 4-mm depth mostly had lower average gaps (P ≤ 0.024). The interactions among the main factors affected the trueness of the tested endocrowns. However, no clear trend emerged that would highlight any subgroup as having the highest trueness. Most endocrowns demonstrated clinically acceptable internal gaps. Tested additively manufactured resin-based endocrowns had favorable internal adaptation. However, they may require more chairside adjustments on external surfaces compared to tested subtractively manufactured endocrowns.

22 January 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
Hanan Al-JohaniHanan Al-Johani
Hanan Al-Johani
AAAbdulaziz Alhotan
Abdulaziz Alhotan
SASaleh Alhijji
Saleh Alhijji
NSNick Silikas
Nick Silikas
JSJulian David Satterthwaite
Julian David Satterthwaite
The influence of different thicknesses, translucencies, and fabrication methods on the spectrophotometric and topographical properties of zirconia-reinforced lithium silicate glass-ceramics (ZLSs) for dental restorations remains unclear. The purpose of this in vitro study was to investigate the effect of thicknesses, translucencies, and fabrication methods on the color stability, translucency parameter, opalescence parameter, whiteness stability, transmitted irradiance, light transmittance, opacity, gloss, and roughness of ZLSs exposed to coffee staining and bleaching treatments. Two pressable ZLSs (VITA AMBRIA, VA and Celtra Press, CP) and 2 machinable ZLSs (VITA Suprinity, VS and Celtra Duo, CD) were examined at high translucency (HT) and low translucency (LT) levels in 2 thicknesses (n=160). The specimens were evaluated at baseline, after coffee staining, and after bleaching. The color stability (ΔE2000), translucency parameter (TP), opalescence parameter (OP), whiteness index (WID), and whiteness stability (ΔWID) were measured with a spectrophotometer. Transmitted irradiance (It), light transmission (T), and opacity (O) were obtained from a light-polymerizing unit and a polymerization light collection device. Roughness stability (ΔSa%) was determined with an optical profilometer, and gloss stability (ΔGU%) was recorded with a gloss meter. Data of ΔCIE2000, ΔWID, ΔSa%, and ΔGU% were analyzed by 4-way ANOVA, and data of the TP, OP, WID, It, T, and O were analyzed by repeated 4-way ANOVA (α=.05). VS-HT exceeded the ΔCIE2000 acceptability threshold after coffee staining and bleaching protocols. Pressable ZLSs exhibited greater color stability than machinable ZLSs. The 1-mm-thick VA, CP, and CD materials exceeded the ΔWID perceptibility threshold after bleaching. The highest TP and OP was displayed by the 1-mm-thick CP after bleaching. ΔGU increased after water storage and decreased after coffee staining and bleaching. ΔSa% significantly increased after bleaching (P<.05). The color stability and other spectrophotometric properties of ZLSs depended on material thickness. The effects of ZLS fabrication methods and translucency levels on their measured properties were inconsistent. Subjecting 1-mm-thick ZLS materials to acidic media adversely impacted their stainability and surface texture.

6 January 2025 in Dental Materials
Verified
Journal Article
Closed access
AAAbdulaziz Alhotan
Abdulaziz Alhotan
Hanan Al-JohaniHanan Al-Johani
Hanan Al-Johani
AAAhmed Altarazi
Ahmed Altarazi
AAAbdullah Alshamrani
Abdullah Alshamrani
AFAhmed Fouda
Ahmed Fouda

17 March 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
FAFiona Cornelia Arnold
Fiona Cornelia Arnold
MDMustafa Borga Donmez
Mustafa Borga Donmez
Hanan Al-JohaniHanan Al-Johani
Hanan Al-Johani
ÇKÇiğdem Kahveci
Çiğdem Kahveci
MSMartin Schimmel
Martin Schimmel
GÇGülce Çakmak
Gülce Çakmak
Additive manufacturing has enabled the fabrication of removable dies in various resins with different compositions. However, the knowledge on the dimensional stability and fit of removable dies fabricated with different dental cast resins is lacking. The purpose of this in vitro study was to evaluate the effect of dental cast resin type and storage time on the dimensional stability and fit of AM removable dies throughout a 4-week period. A typodont model with a prepared right first mandibular molar was digitized with an intraoral scanner (IOS) (CEREC Primescan) to generate a standard tessellation language (STL) file. The STL file was imported into a dental design software program to design a removable die with 10-degree shaft taper angle and a hollow partial arch cast with and without the die. The removable die and hollow partial arch cast without the die STLs were used to additively manufacture 48 removable dies (n=16) and 3 hollow casts (n=1) by using a dental cast resin (DentaMODEL) (AM-DM), a bio-based dental cast resin (FotoDent biobased model) (AM-FD), and a nanographene-reinforced dental cast resin (G-Print) (AM-GP). The same IOS was used to digitize each die and when the die was seated into its respective hollow cast 1 day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. All STL files were imported into a metrology-grade 3-dimensional analysis software program (Geomagic Control X). The root mean square (RMS) was used to assess deviations in different die regions (crown, root, base of the root, and overall) over 4 weeks, along with fit evaluation by calculating RMS for the crown portion within the cast and measuring mean distance deviations at 5 points on the die. The generalized linear model analysis and Bonferroni-corrected post hoc tests were used to evaluate the data (α=.05). The dimensional stability of the removable dies was affected by the interaction between resin type and die region and by the interaction between the resin type and time point, while the fit of the dies was impacted by the interaction between resin type and time point (P<.001). AM-GP dies mostly had higher crown RMS than AM-FD dies (P<.001), while AM-DM dies had the highest root and base of the root RMS (P≤.027). AM-FD dies had the lowest overall RMS (P≤.038). The base of the root led to the highest RMS for each resin (P<.001). AM-FD dies had lower RMS than AM-GP at T0 and AM-DM at T2, while AM-GP dies had lower RMS than AM-DM at T1 (P≤.010). The RMS values of AM-GP dies were lower at T1 than at T0 and T3 (P<.001). When the fit of the dies was considered, AM-FD dies had the lowest and AM-DM dies had the highest crown portion RMS and point-based deviations at each time point (P<.001). In addition, AM-DM dies' RMS values and deviations were the lowest at T0, while AM-FD dies had the highest point-based deviations at T4 (P≤.034). Within tested regions and time points, AM-FD dies mostly had higher dimensional stability and better fit. Therefore, the crowns to be adjusted on AM-FD dies may require fewer interproximal and occlusal adjustments.