Saleh Alhijji

Dr. Saleh Alhijji

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2020 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
MAMohammad D. Al Amri
Mohammad D. Al Amri
NLNawaf Labban
Nawaf Labban
SASaleh Alhijji
Saleh Alhijji
HAHassan Alamri
Hassan Alamri
MIMounir Iskandar
Mounir Iskandar
JPJeffrey A Platt
Jeffrey A Platt

14 July 2023 in Polymers
Verified
Journal Article
Open access
PDF file
OAOmar Alageel
Omar Alageel
SASaleh Alhijji
Saleh Alhijji
OAOmar Alsadon
Omar Alsadon
MAMajed M. Alsarani
Majed M. Alsarani
AGAbdurabu Abdullah Gomawi
Abdurabu Abdullah Gomawi
AAAbdulaziz Alhotan
Abdulaziz Alhotan
Various 3D printing systems for interim fixed dental restorations are commercially available. This study aimed to evaluate the physical and mechanical properties of 3D printed resins used for interim restorations fabricated using various 3D printing systems and printing angulations after accelerated aging. Three different interim restorative materials were provided and printed using their specific 3D printing systems (A: NextDent; B: Asiga; C: Nova3D), and the testing specimens from each system were printed at two building angles: (1) 0° and (2) 90°. The six groups were A1, A2, B1, B2, C1, and C2, with sixteen specimens per group. Half of the specimens in each group (N = 8) were subjected to accelerated aging, including simulated brushing and thermocycling. Three-point bending, surface roughness, and Vickers microhardness tests were performed. Two-way ANOVA and Fisher’s multiple tests were used for statistical analyses. The most accurate systems were found in groups C1 and C2 for length, A1 and B1 for width, and A1 and C1 for height. The specimen trueness only changed after aging for groups B1, B2, and C1. The flexural strength of the A2 group (151 ± 7 MPa) before aging was higher than that of the other groups, and the strength decreased after aging only for groups A1 and A2. The flexural strength, microhardness, and surface roughness of the 3D printed interim resins after aging varied depending on the material, system used, and printing angle.

27 October 2021 in Polymers
Verified
Journal Article
Open access
PDF file
NLNawaf Labban
Nawaf Labban
MAMohammad D. Al Amri
Mohammad D. Al Amri
SASarah Alnafaiy
Sarah Alnafaiy
SASaleh Alhijji
Saleh Alhijji
MAMohammad Alenizy
Mohammad Alenizy
SFSabrina Feitosa
Sabrina Feitosa
The aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The control group was a feldspathic ceramic, Vita Mark II (VM). One hundred and twenty specimens (12 × 14 × 2.5 mm) were prepared using a precision saw. For each material (n = 24), the specimens were allocated into two groups, polished and stained. The specimens of each group were stored (for 7 days) in either citric acid (0.2N) or distilled water. Data for surface gloss (ΔE*SCE-SCI) and roughness (Ra) were evaluated before (baseline) and after simulated toothbrushing. For toothbrushing simulation, a toothpaste slurry containing a toothpaste of 100 relative dentin abrasion (RDA) and 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Data were analyzed using t-test and ANOVA. A p-value of ≤ to 0.05 was considered significant. The highest mean value of surface gloss was identified in CU (stained—water) (4.3 (0.47)) (ΔE*) and EN (stained—acid) (4.3 (1.00)) (ΔE*) specimens, whereas the lowest mean value was shown by SH (stained—acid) (2.04 (0.42)) (ΔE*) samples. The highest mean value of surface roughness was observed in SH (0.40 (0.99)) Ra (stained—acid) whereas the lowest in VM (0.13 (0.039)) Ra (polished— water). A significant difference (p < 0.05) was observed in surface roughness and gloss between the materials with simulated toothbrushing, except in VM and LU, respectively. Therefore, it can be concluded that simulated toothbrushing impacts on surface roughness and gloss, irrespective of the storage medium.

1 January 2021 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
NLNawaf Labban
Nawaf Labban
MAMohammad Al Amri
Mohammad Al Amri
SASaleh Alhijji
Saleh Alhijji
SASarah Alnafaiy
Sarah Alnafaiy
AAAfnan Alfouzan
Afnan Alfouzan
SFSabrina Feitosa
Sabrina Feitosa
Labban N, et al. J Adv Prosthodont. 2021 Feb;13(1):1-11. https://doi.org/10.4047/jap.2021.13.1.1

22 January 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
Hanan Al-JohaniHanan Al-Johani
Hanan Al-Johani
AAAbdulaziz Alhotan
Abdulaziz Alhotan
SASaleh Alhijji
Saleh Alhijji
NSNick Silikas
Nick Silikas
JSJulian David Satterthwaite
Julian David Satterthwaite
The influence of different thicknesses, translucencies, and fabrication methods on the spectrophotometric and topographical properties of zirconia-reinforced lithium silicate glass-ceramics (ZLSs) for dental restorations remains unclear. The purpose of this in vitro study was to investigate the effect of thicknesses, translucencies, and fabrication methods on the color stability, translucency parameter, opalescence parameter, whiteness stability, transmitted irradiance, light transmittance, opacity, gloss, and roughness of ZLSs exposed to coffee staining and bleaching treatments. Two pressable ZLSs (VITA AMBRIA, VA and Celtra Press, CP) and 2 machinable ZLSs (VITA Suprinity, VS and Celtra Duo, CD) were examined at high translucency (HT) and low translucency (LT) levels in 2 thicknesses (n=160). The specimens were evaluated at baseline, after coffee staining, and after bleaching. The color stability (ΔE2000), translucency parameter (TP), opalescence parameter (OP), whiteness index (WID), and whiteness stability (ΔWID) were measured with a spectrophotometer. Transmitted irradiance (It), light transmission (T), and opacity (O) were obtained from a light-polymerizing unit and a polymerization light collection device. Roughness stability (ΔSa%) was determined with an optical profilometer, and gloss stability (ΔGU%) was recorded with a gloss meter. Data of ΔCIE2000, ΔWID, ΔSa%, and ΔGU% were analyzed by 4-way ANOVA, and data of the TP, OP, WID, It, T, and O were analyzed by repeated 4-way ANOVA (α=.05). VS-HT exceeded the ΔCIE2000 acceptability threshold after coffee staining and bleaching protocols. Pressable ZLSs exhibited greater color stability than machinable ZLSs. The 1-mm-thick VA, CP, and CD materials exceeded the ΔWID perceptibility threshold after bleaching. The highest TP and OP was displayed by the 1-mm-thick CP after bleaching. ΔGU increased after water storage and decreased after coffee staining and bleaching. ΔSa% significantly increased after bleaching (P<.05). The color stability and other spectrophotometric properties of ZLSs depended on material thickness. The effects of ZLS fabrication methods and translucency levels on their measured properties were inconsistent. Subjecting 1-mm-thick ZLS materials to acidic media adversely impacted their stainability and surface texture.

17 July 2023 in Polymers
Verified
Journal Article
Open access
PDF file
AAAbdulaziz Alhotan
Abdulaziz Alhotan
RARasha M. Abdelraouf
Rasha M. Abdelraouf
SASaleh Alhijji
Saleh Alhijji
MVMerry Angelyn Tan De Vera
Merry Angelyn Tan De Vera
ASAref Sufyan
Aref Sufyan
Tamer M. HamdyTamer M. Hamdy
Tamer M. Hamdy
Background: One of the crucial factors influencing the longevity of anterior aesthetic dental restorations is the colour stability of resin composites. Bleaching and whitening have become popular methods for enhancing dental aesthetics. Home whitening techniques, such as special pens, are widely available commercially. This in vitro study aimed to determine the efficiency of a whitening pen in removing tea stains from resin composite by measuring colour differences (ΔE00). Additionally, the study aimed to evaluate the variations in colour parameters measured by extra-oral and intra-oral spectrophotometers. Methods: A total of 45 disc-shaped resin composite specimens were randomly divided into three groups; Group 1: stored in artificial saliva (control), Group 2: stored in artificial saliva followed by a whitening pen application, and Group 3: stored in tea followed by a whitening pen application. Colour measurements were taken three times for each specimen using two spectrophotometers (extra-oral and intra-oral devices); T1: before storage (baseline), T2: after storage in artificial saliva or tea for 6 days; and T3: after one week of whitening pen application in groups 2 and 3. The data were statistically analyzed using one-way ANOVA followed by the Tukey post hoc test (p ≤ 0.05). The independent sample t-test was also employed. The equation of CIEDE2000 (ΔE00) was used to calculate the colour difference between the dry, as-prepared specimens (baseline), and those after storage or bleaching. The colour changes exceeding the acceptability threshold (∆E00 = 1.8) were considered unacceptable. Results: After whitening, the colour of the specimens stored in brewed tea (Group 3) remained unacceptable, as indicated by both the extra-oral and intra-oral spectrophotometers (ΔE00 = 4 and 2.9, respectively). Groups 1 and 2 exhibited lower ΔE00 values than Group 3 (p = 0.01 *). No significant difference was observed between Group 1 (stored in artificial saliva) and Group 2 (stored in artificial saliva and then bleached) (p = 0.3). Significant differences were consistently observed between the data obtained from the extra-oral spectrophotometer and the intra-oral one. Conclusions: The whitening pen proved ineffective in removing tea stains from resin composites. Although significant differences were found between the values obtained by the two spectrophotometers (extra-oral and intra-oral), both devices confirmed the unacceptable colour of the tea-stained resin composites after whitening.