Harsha Marupudi

Mr. Harsha Marupudi

University of Illinois Urbana-Champaign
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
GRGregory Romanchek
Gregory Romanchek
YWYuli Wang
Yuli Wang
HMHarsha Marupudi
Harsha Marupudi
SAShiva Abbaszadeh
Shiva Abbaszadeh
In this paper, the room-temperature performance of different optical coupling materials post temperature exposure was tested. The tested couplers included OC431A-LVP, OG0010 optical grease, BLUESIL V-788, and SAINT-GOBAIN BC-630. This was done by subjecting the whole detector with newly applied optical coupling materials to a 2-h temperature exposure—ranging from −20 to 50 °C and then by letting it return to room temperature before collecting a spectrum from a Cs-137 source. The energy resolution at 662 keV was computed as the metric for evaluating the performance. Three trials were run at each coupler–temperature combination. Our results reveal that the performance of all coupling agents do indeed change with temperature after the 2-h exposure. Over all the tested temperature trials, the energy resolution ranged from 11.4 to 14.3% for OC431A-LVP; 10.2 to 14.6% for OG0010; 10 to 13.4% for BLUESIL V-788; and 9.8 to 13.3% for SAINT-GOBAIN BC-630. OC431A-LVP had the lowest variance over the full range, while BC-630 was the most constant for temperatures above 20 °C. Ultraviolet-visible (UV-Vis) spectra experiments were also performed on isolated optical coupling materials to measure the light absorption coefficient. The results show that the temperature-induced variance in light absorption coefficient of each optical coupling materials is one of the reasons for the variance in energy resolution performance. Our findings suggest the need for further investigation into this effect and the recommendation that optical coupling materials need to be selected for the task at hand with greater scrutiny.

1 January 2025 in Journal of Medical Imaging
Verified
Journal Article
Closed access
HMHarsha Marupudi
Harsha Marupudi
JMJoseph A. Manus
Joseph A. Manus
MGMuhammad U. Ghani
Muhammad U. Ghani
SGStephen J. Glick
Stephen J. Glick
Bahaa GhammraouiBahaa Ghammraoui
Bahaa Ghammraoui
PurposeWe evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).ApproachWe employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.1 mm, operated in both standard mode [single pixel (SP)] and charge summing correction mode [anticoincidence (AC)]. A tungsten anode source operated at 55 kVp with 2-mm aluminum external filtration and tube currents of 25, 100, and 200 mA with corresponding exposure times of 20, 5, and 2.5 ms were employed to study the effects of X-ray fluence and pulse pileup. Performance comparisons between AC and SP modes are performed in both projection and image reconstructed spaces. In the projection space, performance metrics include count rate, energy resolution, uniformity, modulation transfer function (MTF), and noise power spectrum (NPS). In the image space, performance metrics consist of contrast-to-noise ratio (CNR), uniformity, NPS, and iodine quantification accuracy. For both acquisition modes, signal-to-thickness calibration, for gain and beam hardening corrections, is used before image reconstruction. Images are reconstructed via TIGRE CT software using the standard Feldkamp, Davis, and Kress (FDK) filtered back projection algorithm with a Hann filter and reconstructed with a voxel size of 0.081 mm. Material decomposition is performed using a standard image-based method.ResultsIn the detector space, the application of hardware-based charge summing correction enhances spectral resolution and improves the spatial resolution of MTF at lower energy thresholds but introduces anomalous edge enhancement effects and artifacts in the MTF at high fluence. A negative noise correlation was observed in AC mode–acquired images. As expected, the AC acquisition mode results in a decreased detector count rate. In the image space, NPS results displayed elevated noise in low-energy AC images. However, at high energy, noise was comparable between both modes. Greater uniformity was observed in SP mode–acquired images. The largest disparity was observed in the iodine quantification test, where the AC mode demonstrates a much stronger linear relationship between estimated and true iodine concentrations than the SP mode.ConclusionThe results are specific to the studied system, reconstruction parameters, and irradiation conditions limited to 200 mA and 0.5 mAs. The AC mode generally provides better energy and MTF resolution at low energy thresholds but with increased noise and reduced uniformity. In image space, charge summing correction improved iodine quantification and CNR at high energy thresholds.

19 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
HMHarsha Marupudi
Harsha Marupudi
Bahaa GhammraouiBahaa Ghammraoui
Bahaa Ghammraoui
Spectral chest radiography with photon-counting detectors (PCDs) enables energy-resolved acquisition for bone/soft-tissue separation, but quantitative performance depends on detector cross-talk and the selected material decomposition algorithm. We performed a controlled simulation study comparing a conventional low-order polynomial decomposition model with two machine learning regressors (multilayer perceptron (MLP) and support vector regression (SVR)) for a cadmium telluride (CdTe) PCD. A Geant4-derived detector response model, coupled with a charge-transport model, was integrated into a physics-forward model including charge sharing and Poisson quantum noise. Digital LucAl/IEC 62220-2-1 phantoms with aluminum and polymethyl methacrylate inserts were used for quantitative bias/root mean square error (RMSE) evaluation, and task-based low-contrast detectability that was evaluated using an exponential transformation of the free-response operating characteristic (EFROC) method using a matched-filter template. Performance was evaluated over clinically relevant dose levels (0.07–7.5 mAs), calibration grid densities (3×3 to 8×8), and numbers of energy thresholds (M=2–6). Polynomial decomposition was stable under sparse calibration, whereas ML methods benefited strongly from denser calibration and additional thresholds; SVR achieved the lowest RMSE under dense calibration, while MLP produced smoother maps and improved soft-tissue detectability at low-to-intermediate dose. At high dose, all methods approached near-ideal detection performance. These results quantify practical trade-offs between calibration requirements, quantitative accuracy, and low-contrast detectability for PCD-based spectral chest radiography.

1 July 2025 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
Bahaa GhammraouiBahaa Ghammraoui
Bahaa Ghammraoui
MBMridul Bhattarai
Mridul Bhattarai
HMHarsha Marupudi
Harsha Marupudi
SGStephen J. Glick
Stephen J. Glick
PurposeAccurate iodine quantification in contrast-enhanced head CT is crucial for precise diagnosis and treatment planning. Traditional CT methods, which use energy-integrating detectors and dual-exposure techniques for material discrimination, often increase patient radiation exposure and are susceptible to motion artifacts and spectral resolution loss. Photon counting detectors (PCDs), capable of acquiring multiple energy windows in a single exposure with superior energy resolution, offer a promising alternative. However, the adoption of these technological advancements requires corresponding developments in evaluation methodologies to ensure their safe and effective implementation. One critical area of concern is the accuracy of iodine quantification, which is commonly assessed using cylindrical phantoms that neither replicate the shape of the human head nor incorporate skull-mimicking materials. These phantoms are widely used not only for testing but also for calibration, which may contribute to an overestimation of system performance in clinical applications. We address the impact of phantom design on evaluation metrics in spectral head CT, comparing conventional cylindrical phantoms to anatomically realistic elliptical phantoms with skull simulants.ApproachWe conducted simulations using a photon-counting spectral CT system equipped with cadmium telluride (CdTe) detectors, utilizing the Photon Counting Toolkit and Tigre CT software for detector response and CT geometry simulations. We compared cylindrical phantoms (20 cm diameter) to elliptical phantoms in three different sizes, incorporating skull materials with major/minor diameters and skull thicknesses of 18/14/0.5, 20/16/0.6, and 23/18/0.7 cm. Iodine inserts at concentrations of 0, 2, 5, and 10 mg/mL with diameters of 1, 0.5, and 0.3 cm were used. We evaluated the influence of bowtie filters, various tube currents, and operating voltages. Image reconstruction was performed after beam hardening correction using the signal-to-thickness calibration (STC) method with standard filtered back projection, followed by both image-based and projection-based material decomposition.ResultsThe results showed that image-based methods were more sensitive to phantom design, with cylindrical phantoms exhibiting enhanced performance compared with anatomically realistic designs across key metrics, including systematic error, root mean square error (RMSE), and precision. By contrast, the projection-based material decomposition method demonstrated greater consistency across different phantom designs and improved accuracy and precision. This highlights its potential for more reliable iodine quantification in complex geometries.ConclusionsThese findings underscore the critical importance of phantom design, especially the inclusion of skull-mimicking materials, in the assessment of quantitative results. Cylindrical phantoms, commonly used for calibration and testing, may overestimate performance in iodine quantification for head CT due to their simplified geometry. We emphasize the need for adopting anatomically realistic phantom designs, such as elliptical phantoms with skull simulants, to enable a more clinically relevant and accurate evaluation of spectral photon-counting head CT systems.