Currently, injection sites of probes, cannula, and optic fibers in stereotactic neurosurgery are typically located manually. This step involves location estimations based on human experiences and thus introduces errors. In order to reduce localization error and improve repeatability of experiments and treatments, we investigate an automated method to locate injection sites. This paper proposes a localization framework, which integrates a region-based convolutional network and a fully convolutional network, to locate specific anatomical points on skulls of rodents. Experiment results show that the proposed localization framework is capable of identifying and locatin bregma and lambda in rodent skull anatomy images with mean errors less than 300 μm. This method is robust to different lighting conditions and mouse orientations, and has the potential to simplify the procedure of locating injection sites.
10 September 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Cadmium zinc telluride (CZT) detectors are suitable for various applications due to the good energy resolution and the simple pixilation to achieve high spatial resolution. Our group is developing a two-panel head-and-neck dedicated positron emission tomography system based on CZT detectors. Each panel will consist of 150 CZT crystals (4 $\times $ 4 $\times $ 0.5 cm 3 ) covering an area of 20 $\times $ 15 cm 2 in an edge-on configuration to achieve high detector efficiency at 511 keV. In this work, we present the design and development of a full data acquisition (DAQ) chain that enables a low noise and compact readout for each panel. The initial results of the readout circuit were quantified using a 1-kHz square wave test pulse. The pulse amplitude was chosen to generate approximately the same amount of charges as a 511-keV photon would provide in CZT. The best-case full width at half maximum (FWHM) electronic noise at 511 keV was measured to be 0.69% ± 0.16% (3.52 ± 0.81 in keV units after conversion). The FWHM electronic noise at 511 keV for a complete DAQ chain was 4.33% ± 0.30% (22.13 ± 1.53 in keV units).
14 October 2020 in Biomedical Physics & Engineering Express
Organ-dedicated PET scanners are becoming more prevalent because of their advantages in higher sensitivity, improved image quality, and lower cost. Detectors utilized in these scanners have finer pixel size with depth of interaction (DOI) capability. This work presents a LYSO(Ce) detector module with DOI capability which has the potential to be scaled up to a high-resolution small animal or organ-dedicated PET system. For DOI capability, a submodule with one LYSO block detector utilizing PETsys TOFPET2 application-specific integrated circuit (ASIC) was previously developed in our lab. We scaled up the submodule and optimized the configuration to allow for a compact housing of the dual-readout boards in one side of the blocks by designing a high-speed dual-readout cable to maintain the original pin-to-pin relationship between the Samtec connectors. The module size is 53.8 × 57.8 mm2. Each module has 2 × 2 LYSO blocks, each LYSO block consists of 4 × 4 LYSO units, and each LYSO unit contains a 6 × 6 array of 1 × 1 × 20 mm3 LYSO crystals. The four lateral surfaces of LYSO crystal were mechanically ground to W14, and the two end surfaces were polished. Two ends of the LYSO crystal are optically connected to SiPM for DOI measurement. Eight LYSO blocks performance including energy, timing, and DOI resolution is characterized with a single LYSO slab. The in-panel and orthogonal-panel spatial resolution of the two modules with 107.4 mm distance between each other are measured at 9 positions within the field of view (FOV) with a 22Na source. Results show that the average energy, timing, and DOI resolution of all LYSO blocks are 16.13% ± 1.01% at 511 keV, 658.03 ± 15.18 ps, and 2.62 ± 0.06 mm, respectively. The energy and timing resolution of two modules are 16.35% and 0.86 ns, respectively. The in-panel and orthogonal-panel spatial resolution of the two modules at the FOV center are 1.9 and 4.4 mm respectively.
In this paper, the room-temperature performance of different optical coupling materials post temperature exposure was tested. The tested couplers included OC431A-LVP, OG0010 optical grease, BLUESIL V-788, and SAINT-GOBAIN BC-630. This was done by subjecting the whole detector with newly applied optical coupling materials to a 2-h temperature exposure—ranging from −20 to 50 °C and then by letting it return to room temperature before collecting a spectrum from a Cs-137 source. The energy resolution at 662 keV was computed as the metric for evaluating the performance. Three trials were run at each coupler–temperature combination. Our results reveal that the performance of all coupling agents do indeed change with temperature after the 2-h exposure. Over all the tested temperature trials, the energy resolution ranged from 11.4 to 14.3% for OC431A-LVP; 10.2 to 14.6% for OG0010; 10 to 13.4% for BLUESIL V-788; and 9.8 to 13.3% for SAINT-GOBAIN BC-630. OC431A-LVP had the lowest variance over the full range, while BC-630 was the most constant for temperatures above 20 °C. Ultraviolet-visible (UV-Vis) spectra experiments were also performed on isolated optical coupling materials to measure the light absorption coefficient. The results show that the temperature-induced variance in light absorption coefficient of each optical coupling materials is one of the reasons for the variance in energy resolution performance. Our findings suggest the need for further investigation into this effect and the recommendation that optical coupling materials need to be selected for the task at hand with greater scrutiny.
Positron emission tomography (PET) suffers from limited spatial resolution in current head and neck cancer management. We are building a dual-panel high-resolution PET system to aid the detection of tumor involvement in small lymph nodes ( 10 mm in diameter). The system is based on cadmium zinc telluride (CZT) detectors with cross-strip electrode readout (1 mm anode pitch and 5 mm cathode pitch). One challenge of the dual-panel system is that the limited angular coverage of the imaging volume leads to artifacts in reconstructed images, such as the elongation of lesions. In this work, we leverage a penalized maximum-likelihood (PML) reconstruction for the limited-angle PET system. The dissimilarity between the image to be reconstructed and a prior image from a low-resolution whole-body scanner is penalized. An image-based resolution model is incorporated into the regularization. Computer simulations were used to evaluate the performance of the method. Results demonstrate that the elongation of the 6-mm and 8-mm diameter hot spheres is eliminated with the regularization strength γ being 0.02 or larger. The PML reconstruction yields higher contrast recovery coefficient (CRC) of hot spheres compared to the maximum-likelihood reconstruction, as well as the low-resolution whole-body image, across all hot sphere sizes tested (3, 4, 6, and 8 mm). The method studied in this work provides a way to mitigate the limited-angle artifacts in the reconstruction from limited-angle PET data, making the high-resolution dual-panel dedicated head and neck PET system promising for head and neck cancer management.
Recent work shows that Pockels effect and optics pump-probe measurement could be utilized as a novel method for 511 keV ionizing radiation photon detection for positron emission tomography (PET) which could potentially overcome the inherent physical limitation for coincidence time resolution of around 100 ps (Tao et al 2016 Phys. Med. Biol . 61 7600–22). In this paper, we embrace this observation and introduce a two-crossed-polarizers based setup to achieve similar detection concept, which is a simpler and more compact setup with comparable ionizing radiation detection capability as the setup used in the previously proposed work. We evaluated the performance of our experimental setup with Lithium Niobate (LiNbO 3 ) and Cadmium Telluride (CdTe) detector crystals, and the desired properties of an ideal detector crystal were discussed. The modulation signal induced by 511 keV photons in both LiNbO 3 and CdTe can be detected with repeatable signal amplitude using two-crossed-polarizers based method, while CdTe could provide eight times higher detection sensitivity to 511 keV photons than LiNbO 3 under the same bias voltage, suggesting high effective Z number and high density properties of CdTe, as well as a shorter carrier lifetime and lower carrier mobility of LiNbO 3 . In addition, the strength of modulation signal increased linearly with bias voltage before saturation. The modulation signal strength in LiNbO 3 continued to increase after 2000 V due to its high resistivity which could reduce the dark current in the detector, while the modulation signal of CdTe with low resistivity tended to be saturated at a bias voltage higher than 1200 V. Therefore, further increasing the bias voltage for detector crystals (especially for LiNbO 3 ) may enhance the modulation strength and improve the detection sensitivity for annihilation photons.