Honglei Deng

Dr. Honglei Deng

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
Gang LiuGang Liu
Gang Liu
DGDeming Guo
Deming Guo
PWPengyu Wang
Pengyu Wang
HDHonglei Deng
Honglei Deng
XHXiaobin Hong
Xiaobin Hong
WTWenhu Tang
Wenhu Tang
Ground wire breakage accidents can destroy the stable operation of overhead lines. The excessive temperature increase arising from the contact resistance between the ground wire and armor rod in the contact terminal is one of the main reasons causing the breakage of ground wires. Therefore, it is necessary to calculate the equivalent resistance for ground wires twined with armor rods in contact terminals. According to the actual distribution characteristics of the contact points in the contact terminal, a three-dimensional electromagnetic field simulation model of the contact terminal was established. Based on the model, the current distribution in the contact terminal was obtained. Subsequently, the equivalent resistance of a ground wire twined with the armor rod in the contact terminal was calculated. The effects of the factors influencing the equivalent resistance were also discussed. The corresponding verification experiments were conducted on a real ground wire on a contact terminal. The measurement results of the equivalent resistance for the armor rod segment showed good agreement with the electromagnetic modeling results.

8 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
ZLZhao Liu
Zhao Liu
HDHonglei Deng
Honglei Deng
RPRuidong Peng
Ruidong Peng
XPXiangyang Peng
Xiangyang Peng
RWRui Wang
Rui Wang
Gang LiuGang Liu
Gang Liu
With the increase in electricity demand, the ampacity calculation based on the dynamic thermal rating (DTR) technology is increasingly significant for assessing and improving the power transfer capacity of the existing overhead conductors. However, the DTR models now available present some inadequacies in measurement techniques related to wind speed. Therefore, it is essential to propose a new model instead of wind speed measuring in DTR technology. In this paper, the influence analysis of various weather parameters on the conductor ampacity is carried out by using the real weather data. Based on the analysis, it is confirmed that the impact of wind speed is significant, especially in the case of the low wind speed. Moreover, an equivalent heat transfer (EHT) model for DTR technology is proposed instead of wind speed measuring. For this EHT model, the calculation of conductor ampacity is realized through investigating the correlation of heat losses between the heating aluminum (Al) ball and conductor. Finally, combined with the finite element method (FEM), the EHT model proposed in this paper is verified by the Institute of Electrical and Electronic Engineers (IEEE) standard. The results indicate that the error of the EHT model is less than 6% when employing the steady thermal behavior of the Al ball to calculate the ampacity. The EHT model is useful in the real-time thermal rating of overhead conductors. It can increase the utilization of overhead conductors while also avoiding the limitation of the existing measurement techniques related to wind speed.

Verified
Journal Article
Open access
PDF file
ZZZikai Zhou
Zikai Zhou
YGYaxun GUO
Yaxun GUO
XJXiaofeng Jiang
Xiaofeng Jiang
Gang LiuGang Liu
Gang Liu
WTWenhu Tang
Wenhu Tang
MZMing Zheng
Ming Zheng
For the study of transient overvoltage (TOV) in an offshore wind farm (OWF) collector system caused by switching off vacuum circuit breakers (VCBs), a simplified experimental platform of OWF medium-voltage (MV) cable collector system was established in this paper to conduct switching operation tests of VCB and obtain the characteristic parameters for VCB, especially dielectric strength parameters; also, the effectiveness of the VCB reignition model was verified. Then, PSCAD/EMTDC was used to construct the MV collector system of the OWF, and the effects of normal switching and fault switching on TOV amplitude, steepness, and the total number of reignition of the VCB were studied, respectively, with the experimental parameters and traditional parameters of dielectric strength of the VCB. The simulation results show that when the VCB is at the tower bottom, the overvoltage amplitude generated by the normal switching is the largest, which is 1.83 p.u., and the overvoltage steepness of the fault switching is the largest, up to 142 kV/μs. The overvoltage amplitude and steepness caused by switching off VCB at the tower bottom faultily with traditional parameters are about 2 and 1.5 times of the experimental parameters under the same operating condition.

3 March 2025 in Energy
Verified
Journal Article
Closed access
HDHonglei Deng
Honglei Deng
ZGZiheng Gao
Ziheng Gao
ZXZhixiang Xing
Zhixiang Xing
PWPengyu Wang
Pengyu Wang
GLGang Liu
Gang Liu

6 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
HTHua Tu
Hua Tu
CPChao Peng
Chao Peng
YCYanyi Chen
Yanyi Chen
LLLixing Li
Lixing Li
HDHonglei Deng
Honglei Deng
Gang LiuGang Liu
Gang Liu
Nuclear Instrumentation and Control (I&C) cables laying in a complex environment are prone to shield damage. And, the traveling wave reflection method can be used to detect and locate damage using the characteristic impedance change caused by I&C cable damage. Therefore, this paper establishes a quasi-coaxial cable shield characteristic impedance calculation model. And, it brings in the defective circumferential angle of the damage coefficient. Then, it builds a quasi-coaxial I&C characteristic impedance model approximation of the multi-core cable structure combined. Finally, the results of this paper through calculations and simulations are as follows. Firstly, the characteristic impedance of the cable with eccentricity e equal to 2.57 mm is stabilized at 37.795 Ω with increasing frequency. Second, the difference in the computational model is 3.88 Ω at 10 MHz of frequency, and a less than 3% difference in model approximation of a four-core cable at 5 MHz of frequency. Third, the calculation model can control the error of the characteristic impedance calculation result within 4 Ω within the defect angle of 270°. These results validate the reasonableness of the model.

28 November 2024 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
HDHonglei Deng
Honglei Deng
YCYanyi Chen
Yanyi Chen
LLLixing Li
Lixing Li
YZYifeng Zhao
Yifeng Zhao
HTHua Tu
Hua Tu
GLGang Liu
Gang Liu