Hsiang-Cheng Hsu

Dr. Hsiang-Cheng Hsu

National Kaohsiung University of Science and Technology, Kaohsiung City, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2023 in Measurement
Verified
Journal Article
Closed access
TNThi Thuy-Vy Nguyen
Thi Thuy-Vy Nguyen
HLHoang-Dang Le
Hoang-Dang Le
HHHsiang-Cheng Hsu
Hsiang-Cheng Hsu
CNChi-Ngon Nguyen
Chi-Ngon Nguyen
CCChia-Chin Chiang
Chia-Chin Chiang

16 March 2023 in Optik
Verified
Journal Article
Closed access
HLHoang-Dang Le
Hoang-Dang Le
CCChia-Chin Chiang
Chia-Chin Chiang
CNChi-Ngon Nguyen
Chi-Ngon Nguyen
HHHsiang-Cheng Hsu
Hsiang-Cheng Hsu

29 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HLHoang-Dang Le
Hoang-Dang Le
CCChia-Chin Chiang
Chia-Chin Chiang
CNChi-Ngon Nguyen
Chi-Ngon Nguyen
HHHsiang-Cheng Hsu
Hsiang-Cheng Hsu
This work proposes and experimentally validates a 2D low- and medium-frequency fiber Bragg grating (FBG) acceleration sensor. The investigation of the vibration sensor uses a symmetrical circular flexure hinge structure with similar sensitivity in both measuring directions. The two FBGs are arranged differently to avoid a temperature impact; the sensitivity is double that of only one FBG fiber. First, the operating theory and theoretical system of the FBG accelerometer were analyzed. Second, the theoretical research and optimization improved the FBG sensor’s design, resonance frequency, and sensitivity. Third, the viability of the optimization findings and the simulation was evaluated using ANSYS software. Finally, the product was created, and the sensor calibration was performed using the simulation results. The theoretical values and experimental findings largely concur. According to performance tests, the resonance frequencies in the x- and y-direction are 440 and 500 Hz, respectively, with a flat frequency range from 20 to 300 Hz. Furthermore, the sensor shows average sensitivities along the two spatial dimensions of 124 and 83 pm/G, respectively. The overall anti-interference between the two measuring directions is less than 6%. This sensor is useful in various applications, including vibration monitoring, machine condition monitoring, and robotics.

1 June 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TNThi Thuy-Vy Nguyen
Thi Thuy-Vy Nguyen
HLHoang-Dang Le
Hoang-Dang Le
HHHsiang-Cheng Hsu
Hsiang-Cheng Hsu
CNChi-Ngon Nguyen
Chi-Ngon Nguyen
CCChia-Chin Chiang
Chia-Chin Chiang
This paper proposes a novel vibration sensor based on fiber Bragg grating (FBG) technology. The sensor employs a V-shaped flexure hinge structure, which is theoretically and experimentally demonstrated to enhance sensitivity for vibration sensing. The proposed design utilizes the V-shaped flexures hinge to focus the acceleration-induced strain, resulting in improved performance for vibration sensitivity. The implementation of the FBG sensor was evaluated through theoretical computations using MATLAB. The simulation software was also used to simulate the proposed structure and assess the parameters affecting its sensing performance. The experimental results of this work sensor demonstrate a sensitivity of 79.46 pm/G and a resonant frequency of 1140 Hz. The sensor’s operating frequency bandwidth was 30–320 Hz, while the temperature influence was measured at 8.5 pm/°C. In addition, the amplitude in the transverse direction was only 3% of the amplitude in the working principle, indicating that the presented sensor has solid lateral immunity. The experimental results were consistent with the simulation findings, demonstrating the presented vibration sensor’s good performance. The given work provides an opportunity to apply the FBG acceleration sensor in the high-dependability detection of low- and medium-frequency vibration signals.

16 February 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
HWHsin-Yi Wen
Hsin-Yi Wen
CCChia-Chin Chiang
Chia-Chin Chiang
RCRou-Yu Chen
Rou-Yu Chen
WNWei-Zhi Ni
Wei-Zhi Ni
YWYu-Qiao Weng
Yu-Qiao Weng
HHHsiang-Cheng Hsu
Hsiang-Cheng Hsu
Rheumatoid arthritis (RA) is regarded as a chronic, immune-mediated disease that leads to the damage of various types of immune cells and signal networks, followed by inappropriate tissue repair and organ damage. RA is primarily manifested in the joints, but also manifests in the lungs and the vascular system. This study developed a method for the in vitro detection of RA through cyclic citrullinated peptide (CCP) antibodies and antigens. The diameter of a tilted-fiber Bragg grating (TFBG) biosensor was etched to 50 μm and then bonded with CCP antigens and antibodies. The small variations in the external refractive index and the optical fiber cladding were measured. The results indicated that the self-assembled layer of the TFBG biosensor was capable of detecting pre- and post-immune CCP antigen and CCP peptide concentrations within four minutes. A minimum CCP concentration of 1 ng/mL was detected with this method. This method is characterized by the sensor’s specificity, ability to detect CCP reactions, user-friendliness, and lack of requirement for professional analytical skills, as the detections are carried out by simply loading and releasing the test samples onto the platform. This study provides a novel approach to medical immunosensing analysis and detection. Although the results for the detection of different concentrations of CCP antigen are not yet clear, it was possible to prove the concept that the biosensor is feasible even if the measurement is not easy and accurate at this stage. Further study and improvement are required.

14 May 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HHHsiang-Cheng Hsu
Hsiang-Cheng Hsu
TTTien-Bao Tran
Tien-Bao Tran
TNThi Thuy-Vy Nguyen
Thi Thuy-Vy Nguyen
HLHoang-Dang Le
Hoang-Dang Le
CCChia-Chin Chiang
Chia-Chin Chiang
This study introduces a successfully manufactured U-shaped optical fiber sensor integrated with a microfluidics system to detect varying glucose concentrations. It outlines the fabrication process of the microfluidics system, accomplished using a CO2 laser on polymethyl methacrylate (PMMA) material. Through three cycles of experiments involving different glucose concentrations, the results indicate a consistent trend in both resonance wavelength and transmission loss, showing an increase as glucose concentration rises from 5% to 50%. The system demonstrates a high wavelength sensitivity coefficient of 0.114 nm/% with ${R}^{{2}} =0.95$ and a notable transmission loss sensitivity of 0.09 dB/% and ${R}^{{2}} =0.94$ . This advanced system proves to be effective in achieving rapid, sensitive, and cost-efficient glucose monitoring. Consequently, the microfluidics system is deemed suitable for its intended purpose.