Pneumonia is an inflammation of the lung parenchyma that is caused by a variety of infectious microorganisms and non-infective agents. All age groups can be affected; however, in most cases, fragile groups are more susceptible than others. Radiological images such as Chest X-ray (CXR) images provide early detection and prompt action, where typical CXR for such a disease is characterized by radiopaque appearance or seemingly solid segment at the affected parts of the lung due to inflammatory exudate formation replacing the air in the alveoli. The early and accurate detection of pneumonia is crucial to avoid fatal ramifications, particularly in children and seniors. In this paper, we propose a novel 50 layers Convolutional Neural Network (CNN)-based architecture that outperforms the state-of-the-art models. The suggested framework is trained using 5852 CXR images and statistically tested using five-fold cross-validation. The model can distinguish between three classes: viz viral, bacterial, and normal; with 99.7% ± 0.2 accuracy, 99.74% ± 0.1 sensitivity, and 0.9812 Area Under the Curve (AUC). The results are promising, and the new architecture can be used to recognize pneumonia early with cost-effectiveness and high accuracy, especially in remote areas that lack proper access to expert radiologists, and therefore, reduces pneumonia-caused mortality rates.
A corneal ulcer is an open sore that forms on the cornea; it is usually caused by an infection or injury and can result in ocular morbidity. Early detection and discrimination between different ulcer diseases reduces the chances of visual disability. Traditional clinical methods that use slit-lamp images can be tiresome, expensive, and time-consuming. Instead, this paper proposes a deep learning approach to diagnose corneal ulcers, enabling better, improved treatment. This paper suggests two modes to classify corneal images using manual and automatic deep learning feature extraction. Different dimensionality reduction techniques are utilized to uncover the most significant features that give the best results. Experimental results show that manual and automatic feature extraction techniques succeeded in discriminating ulcers from a general grading perspective, with ~93% accuracy using the 30 most significant features extracted using various dimensionality reduction techniques. On the other hand, automatic deep learning feature extraction discriminated severity grading with a higher accuracy than type grading regardless of the number of features used. To the best of our knowledge, this is the first report to ever attempt to distinguish corneal ulcers based on their grade grading, type grading, ulcer shape, and distribution. Identifying corneal ulcers at an early stage is a preventive measure that reduces aggravation and helps track the efficacy of adapted medical treatment, improving the general public health in remote, underserved areas.
A corneal ulcers are one of the most common eye diseases. They come from various infections, such as bacteria, viruses, or parasites. They may lead to ocular morbidity and visual disability. Therefore, early detection can reduce the probability of reaching the visually impaired. One of the most common techniques exploited for corneal ulcer screening is slit-lamp images. This paper proposes two highly accurate automated systems to localize the corneal ulcer region. The designed approaches are image processing techniques with Hough transform and deep learning approaches. The two methods are validated and tested on the publicly available SUSTech-SYSU database. The accuracy is evaluated and compared between both systems. Both systems achieve an accuracy of more than 90%. However, the deep learning approach is more accurate than the traditional image processing techniques. It reaches 98.9% accuracy and Dice similarity 99.3%. However, the first method does not require parameters to optimize an explicit training model. The two approaches can perform well in the medical field. Moreover, the first model has more leverage than the deep learning model because the last one needs a large training dataset to build reliable software in clinics. Both proposed methods help physicians in corneal ulcer level assessment and improve treatment efficiency.
This study aimed to generate synthetic MR images from real CT images. CT# mean and standard deviation of a moving window across every pixel in the reconstructed CT images were mapped to their corresponding tissue-mimicking types. Identification of the tissue enabled remapping it to its corresponding intrinsic parameters: T1, T2, and proton density (ρ). Lastly, synthetic weighted MR images of a selected slice were generated by simulating a spin-echo sequence using the intrinsic parameters and proper contrast parameters (TE and TR). Experiments were performed on a 3D multimodality abdominal phantom and on human knees at different TE and TR parameters to confirm the clinical effectiveness of the approach. Results demonstrated the validity of the approach of generating synthetic MR images at different weightings using only CT images and the three predefined mapping functions. The slope of the fitting line and percentage root-mean-square difference (PRD) between real and synthetic image vector representations were (0.73, 10%), (0.9, 18%), and (0.2, 8.7%) for T1-, T2-, and ρ-weighted images of the phantom, respectively. The slope and PRD for human knee images, on average, were 0.89% and 18.8%, respectively. The generated MR images provide valuable guidance for physicians with regard to deciding whether acquiring real MR images is crucial.
In this study, the authors present a simple, reliable, fast, unrestricted‐shape geometry, and accurate algorithm which runs in O (log 2n ) time to find the axis‐parallel largest rectangle (LR) inside a given region of interest (ROI), where n is the image size in one dimension, which means that the proposed model can work in real time. The proposed approach is successful in detecting the LR of arbitrary orientation that is fully contained in the ROI as well. Also, the present algorithm can find the largest empty rectangle in a space containing a set of zero points, whether the axis‐parallel rectangle or the oriented one. The strategy followed here is to accelerate LR detection process by searching the rectangle with the largest area inscribed in the ROI, by starting first with the lowest‐resolution version of the original image for determining the LR four corners’ coordinates, then next searching the new LR corners’ scaled coordinates in the higher power resolutions in a multiple resolutions hierarchical model and therefore, a corresponding coarse‐to‐fine inference procedure recursively eliminates the search space of the LR four corners coordinates. For finding the largest oriented rectangle, the same hierarchical procedures are followed, but combined with rotation‐angle resolution.
1 October 2018 in Pattern Recognition and Image Analysis
Shape recognition is considered as one of the challenges in automated digital image analysis and computer vision. One of the most commonly used shapes is the ellipse which is of great importance for...