Neck injuries and pathologies are widespread and cause disability. Clinicians use different tools to measure the cervical spine’ mobility to diagnose different disorders. There are many reliable assessment methods for this purpose, but their benefits have not been deeply investigated and compared, as well as their measurement results. This review aims to summarise the advantages, accuracy, and reliability, of measurement tools and devices used in studies or trails related to the neck and cervical spine evaluation, to evidence the use of inertial sensors and compare them, to highlight the best assessment systems and their characteristics. A literature review has been performed in a range of five years, to obtain information about cervical spine evaluation. Studies that met the established inclusion criteria were selected and classified according their pathology studied, objectives and methodologies followed when evaluating the cervical spine functionality. Studies were described chronologically highlighting the tools employed, where the motion capture systems and cervical range of motion devices stood out as the most used and reliable methods. Cervical spine assessment studies employing systems with inertial sensors as an accurate method, is not evidenced in the sample. However, they are widely tested and different studies validate these systems for their clinical area use, obtaining high reliability and repeatability. Thereby, this review argues that inertial sensors have proven to be a portable, and easy to use tool for the evaluation of neck and its related pathologies, with a great accuracy level.
In this work, the mechanical aspect of a compact prototype of transhumeral prosthesis with flexo-extension and prone-supination movements is presented. The torque and maximum speed of the elbow and wrist joints were established based on activities of daily living. Lengths, circumferences, and maximum weight were adjusted to anthropometric measurements of the Latin American population. Materials and transmission mechanisms were selected using property pondering matrices. Safety factors and displacements were checked by means of numerical simulation. The parts were manufactured by machining and 3D printing. The mechanism was assembled and validated using the design loads. The mechanism measures 7 cm from the elbow to the arm coupling. It can move objects up to 450 g with retention and up to 2 kg without retention, with maximum speeds of 30 rpm and 20 rpm for the elbow and wrist joints, respectively. The ranges of movement are flexion, 130°; extension, 30°; pronation, 90°; supination, 90°. The prototype is compact enough to be used in cases of long amputation. The speeds, ranges of motion and load capabilities are suitable for most activities of daily life.
The present research exposes the wrist position estimation through electromyographic signals, to achieve this, the selection of the angular positions in the movements Flexion- Extension and Abduction-Adduction was made, being the main basis for the development of this investigation. Subsequently, the muscles from which the myoelectric signals were extracted were chosen, according to parameters such as muscle size, superficiality and the contribution to the movement in execution. A study muscle was defined for each movement, electromyographic samples were extracted with the help of electronic cards and surface electrodes of Silver / Silver Chloride (Ag / AgCl), then a database was formed of each movement. A database is formed, the processing, conditioning and digitalization of the signal was carried out; next, the characterization was performed with time domain analysis, obtaining the specific characteristics of the EMG signal. Subsequently, to obtain the main characteristics, machine learning techniques were applied, analyzing the classification with several supervised type algorithms such as Neural Networks, Vector Support Machines, Discriminated Analysis and Nearest Neighbor; this, in order to find an optimal classifier that allows the successful identification of the movement. The research’s main claim is to carry out in order to use this methodology in the creation of wrist rehabilitation systems.
Currently, dynamic compression plates are widely used in internal fracture fixation processes. The pressure exerted on the fractured bones achieves the generation of the bone callus, consolidating the anatomical portion. The geometry of these plates is very irregular, therefore, to know their elastic performance, under the action of loads, it is necessary to use computer programs based on numerical methods of approximation. In this work, the experimental validation of a plate is developed, for a diaphyseal fracture of the forearm. It is compared to a computational model, which was previously analyzed, using the boundary elements method. An iterative domain decomposition technique, due to the presence of non-homogeneous materials such as bone and steel, is applied. The plate was made of AISI 316L stainless steel and tested using a GALDABINI test machine, model 34/M. The experimental results allowed the validation of the contour conditions imposed in the numerical simulation. Finally, an osteosynthesis device that resists a load of 50 N appropriate for diaphyseal fractures of the forearm bones is presented.