Brizeida Nohemi Gamez

Brizeida Nohemi Gamez

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
CACristina Gabriela Ayala
Cristina Gabriela Ayala
FVFernando Vinicio Valencia
Fernando Vinicio Valencia
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
HSHugo Salazar
Hugo Salazar
DODavid Alberto Ojeda
David Alberto Ojeda
Background: The need to improve gait emulation in people with amputation has driven the development of customized prosthetic mechanisms. This study focuses on the design and validation of a mechanism for external knee joint prostheses, based on the trajectory of the Instantaneous Center of Rotation (ICR) of a healthy knee. Objective: The objective is to design a mechanism that accurately reproduces the evolution of the ICR trajectory, thereby improving stability and reducing the user’s muscular effort. Methods: An exploratory methodology was employed, utilizing computer-aided design (CAD), kinematic simulations, and rapid prototyping through 3D printing. Multiple configurations of four- and six-bar mechanisms were evaluated to determine the ICR trajectory and compare it with a reference model obtained in the laboratory from a specific subject, using MATLAB-2023a and the Fréchet distance as an error metric. Results: The results indicated that the four-bar mechanism, with the incorporation of a simple gear train, achieved a more accurate emulation of the ICR trajectory, reaching a minimum error of 6.87 mm. Functional tests confirmed the effectiveness of the design in terms of stability and voluntary control during gait. It can be concluded that integrating the mechanism with the gear train significantly enhances its functionality, making it a viable alternative for the development of external knee prostheses for people with transfemoral amputation, based on the ICR of the contralateral leg.

29 July 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
CACristina Gabriela Ayala
Cristina Gabriela Ayala
FVFernando Valencia
Fernando Valencia
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
HSHugo Salazar
Hugo Salazar
DODavid Alberto Ojeda
David Alberto Ojeda
: The need to improve gait emulation in patients with transfemoral amputation has led to the development of customized prosthetic mechanisms. This study focuses on the design and validation of an external knee joint prosthesis mechanism, based on the trajectory of the Instantaneous Center of Rotation (ICR) of a healthy knee. The goal is to design a mechanism that closely follows the evolution of the ICR path, improving stability and reducing the user's muscle effort. An exploratory methodology was applied, using computer-aided design (CAD), kinematic simulations, and rapid prototyping with 3D printing. Several four-bar and six-bar mechanism configurations were evaluated by determining their ICR trajectories and comparing them to a reference model obtained in the lab from a specific patient, using MATLAB and Fréchet distance as the error metric. The results showed that the optimized four-bar mechanism, with the addition of gears, achieved the highest accuracy in matching the ICR trajectory, with a minimum error of 5 mm. Functional tests confirmed the effectiveness of the design in terms of stability and voluntary control during walking. It is concluded that optimizing the mechanism design based on the ICR significantly improves functionality and supports its clinical implementation and impact on users’ quality of life.

7 January 2026 in Biomechanics
Verified
Journal Article
Open access
PDF file
FVFernando Vinicio Valencia
Fernando Vinicio Valencia
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
DODavid Alberto Ojeda
David Alberto Ojeda
HSHugo Salazar
Hugo Salazar
Objective: The purpose of this study is to develop a mechatronic device capable of characterizing the kinematics of the knee joint, based on the acquisition and analysis of data focused on the knee joint point. Methods: A mechatronic device was designed using dimensional data from a participant’s lower limb (1.59 m, 57 kg), obtained through 3D scanning. The device, based on a proportional mechanism aligned with anatomical reference points, allows the evolution of the knee joint pivot point (PPKJ) to be recorded. Ten healthy subjects (aged 22–26 years, height 1.50–1.63 m, body mass 48–59 kg) were selected for testing. The device was placed on each knee to record joint trajectories during squats. The trajectories were classified into two groups: extension to flexion and flexion to extension. For each group, the average trajectory was calculated. Results: Forty PPKJ trajectories were obtained, divided into two sets: extension to flexion with a range of 8° to 51.3° and flexion to extension with a range of 6.7° to 56.83°, which allowed the mean trajectory and cubic polynomial regression to be calculated as the best approximation for characterizing the trajectory of the instantaneous center of rotation of the knee joint. Conclusions: The developed mechatronic device offers an accessible and non-invasive solution for recording the trajectory of the knee joint pivot point in individuals with characteristics like those in the study. This alternative approach could improve the representation of knee kinematics in the design of customized prostheses, exoskeletons, and rehabilitation devices for lower limbs.

25 October 2021 in Journal of Surgical Case Reports
Verified
Journal Article
Open access
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
JBJ Benitez
J Benitez
FPF Puelma
F Puelma
NJN Jarufe
N Jarufe
Only a few centers in the world perform pure laparoscopic right hepatectomy for adult-to-adult living donor liver transplantation. In this procedure, right lobe donation is mostly preferred in view of the higher graft volume usually needed for the recipient. In the area, laparoscopic surgery has had a minor development given the greater technical difficulty and risks for both donor and preservation of the graft. Nevertheless, last 3 years, the advances in major laparoscopic liver surgery suggest that pure laparoscopic right hepatectomy could be a feasible and safe procedure in appropriately selected donors, and mostly, when is performed by surgeons with significant experience in both laparoscopic liver surgery and liver transplantation with living donor liver grafts. This video shows the surgical technique of a pure laparoscopic right hepatectomy in a 30-year-old female volunteered for living donation to her brother.

3 March 2020
Verified
Book Chapter
Closed access
PDF file
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
DODavid Ojeda
David Ojeda
MSMarco Ciaccia-Sortino, PhD Ciaccia Sortino
Marco Ciaccia-Sortino, PhD Ciaccia Sortino
IIIván Iglesias-Navarro
Iván Iglesias-Navarro

6 October 2023
Verified
Book Chapter
Closed access
PDF file
MFMaythe Mieles Freire
Maythe Mieles Freire
Luz M. Tobar-Subía-ContentoLuz M. Tobar-Subía-Contento
Luz M. Tobar-Subía-Contento
BGBrizeida Nohemi Gamez
Brizeida Nohemi Gamez
GCGuillermo Mosquera Canchingre
Guillermo Mosquera Canchingre