Additive manufacturing is increasingly integrated into dental technology, yet the mechanical performance of 3D-printed denture base resins remains strongly influenced by printing orientation and post-curing duration. This study evaluated the combined effect of three printing orientations (0°, 45°, 90°) and three post-curing times (30, 45, 60 min) on the flexural strength and surface microhardness of a denture base resin. Specimens designed in Blender and fabricated using NextDent Denture 3D+ resin were subjected to three-point bending tests (n = 5 per group) and Vickers microhardness measurements (n = 10 per group). One-way ANOVA assessed main and interaction effects. Printing orientation had a significant influence on flexural strength, with horizontally printed specimens exhibiting the highest values, whereas vertically printed specimens were consistently weaker. Post-curing time did not significantly affect flexural strength within any orientation. In contrast, microhardness increased progressively with longer post-curing durations, regardless of orientation, indicating continued surface polymerisation. Because flexural strength and hardness responded differently to curing duration, no single post-curing time was universally optimal; however, 0° printing consistently produced the strongest specimens for this resin–printer system. This trade-off is clinically relevant, because dentures require high flexural strength to resist fracture and sufficient hardness to minimise wear.
Additive manufacturing is now an integral part of digital prosthodontic workflows, and although stereolithography (SLA) is widely used for denture base fabrication, the dimensional accuracy of printed dentures remains highly dependent on manufacturing parameters, particularly build orientation. This study evaluated the influence of build orientation on the trueness and precision of SLA-printed maxillary and mandibular denture bases. Thirty complete denture bases were fabricated using SLA and divided into three groups according to build orientation: 0°, 45°, and 90° (n = 10). The intaglio surfaces of the printed dentures were scanned and compared with their corresponding digital reference models using three-dimensional inspection software. Trueness was quantified using root mean square error (RMSE) and directional deviations, while precision was assessed based on the variability of RMSE values within each group. Statistical analysis was performed using one-way ANOVA and Tukey’s post hoc test (p ≤ 0.05). Build orientation significantly affected the trueness of maxillary denture bases, with dentures printed at 90° demonstrating the lowest RMSE values. No statistically significant differences in trueness were observed among build orientations for mandibular denture bases. Precision was not influenced by build orientation for maxillary dentures, whereas mandibular dentures printed at 90° exhibited significantly greater variability compared with 0° and 45°. Build orientation is a critical factor influencing the dimensional accuracy of SLA-printed denture bases in an arch-dependent manner. Optimizing build orientation may enhance both accuracy and reproducibility, thereby improving the predictability and clinical reliability of additively manufactured denture bases.
24 July 2024 in Journal of IMAB – Annual Proceeding (Scientific Papers)
Introduction: Despite the progress of additive manufacturing, there are different opinions regarding microbial adhesion on the surface of 3D printed dentures and the biocompatiability of the materials. The purpose of this in-vivo study was to determine the presence of Candida species in the saliva, oral mucosa and on dentures of patients wearing heat-cured polymethylmethacrylate (PMMA) and 3D-printed prosthetic appliances after a three-month period of observation. Materials and methods: The clinical study included 40 edentulous patients, divided into two groups - first group (A) –wearing conventional dentures and second group (B) – wearing 3D printed dentures. It was used chrom agar Candida (Bio Merieux) for identification and quantity assessment of the presence of Candida spp. and spectrophotometric analysis using VITEK MS (Bio Merieux). Results: After three months of wearing the dentures, Candida spp was not isolated in the saliva in 60% of patients in group A and 70% of group B, with no statistically significant difference between the results before the treatment and after the third month. In the third month, Candida spp was isolated from the oral mucosa of 20% of group A and in group B – 10%, with no significant difference between the groups (p<0.05). No Candida spp was isolated from 90% of denture surfaces in both groups. Conclusion: The adhesion of Candida spp. to 3D printed dentures is not higher than conventional dentures made from heat-curing resin. Also, there is no difference between the amount of Candida spp. in the saliva, oral mucosa and denture surfaces.
Purpose/Objectives: Tooth morphology is a fundamental aspect of dental education, essential for various clinical disciplines. Traditional teaching methods, such as 2D visualizations, gypsum models, and wax or soap carving, have been widely used to develop students’ spatial understanding and manual skills. However, the integration of 3D‐printed models offers a novel approach that may enhance learning by providing a more accurate representation of dental morphology. This study aimed to assess the effectiveness of 3D‐printed models in learning tooth morphology by comparing their impact on students' practical and theoretical performance with traditional teaching methods. Methods: Dental students were divided into two groups: one utilizing 3D‐printed models alongside traditional methods and another relying solely on conventional gypsum and 2D visualizations. Practical assessments included soap tooth carving and wax modelling, while theoretical knowledge was evaluated through a written examination. Additionally, students completed a questionnaire to provide feedback on their experience with the 3D‐printed models. Results: Students who used 3D‐printed models achieved significantly higher scores in the soap tooth carving task, demonstrating improved accuracy and anatomical detail. However, there was no significant difference in the wax modelling scores between the two groups, suggesting that advanced manual dexterity skills are not solely dependent on 3D visualization. Theoretical examination results also showed no significant difference, indicating that 3D models primarily enhance practical skills rather than theoretical comprehension. Over 80% of students reported that 3D‐printed models were highly beneficial in understanding tooth anatomy and improving carving skills. Conclusion(s): The findings suggest that 3D‐printed models serve as a valuable tool for enhancing practical skills in dental education. While they do not replace traditional methods, they effectively support hands‐on learning and visualization.
8 July 2025 in Journal of IMAB – Annual Proceeding (Scientific Papers)
Introduction: Tooth color is a key determinant of dental aesthetics and critically influences patient satisfaction. Traditional shade matching is subjective and inconsistent, while spectrophotometry offers standardized, reproducible, and objective measurements. Defining the natural color profiles of anterior teeth in young adults is essential for predictable and high-quality esthetic restorations. The purpose of this study is to analyze the color characteristics of the maxillary central incisors, lateral incisors, and canines in a population of young adults aged 18–21 using a spectrophotometer (Spectroshade; MHT Optic Research). Materials and Methods: Color measurements were conducted on 153 dental students aged 18–21 years using the SpectroShade Micro spectrophotometer. The teeth examined were maxillary central (11, 21), lateral incisors (12, 22) and canines (13, 23). VITA Classical shades were matched and subsequently converted to CIELAB values (L*, a*, b*). Statistical analysis included mean, SD, and one-way ANOVA (α = 0.05). Results: The central incisors had the highest L* (lightness) values, indicating greater brightness. Canines presented significantly higher b* values, reflecting more pronounced yellowness. Statistically significant differences (p < 0.05) were observed among the tooth groups. Conclusion: Color parameters of anterior teeth vary significantly between tooth types in young adults. These findings are valuable for aesthetic restorative procedures and provide a reference for shade selection in this age group.
Aim: This study aimed to compare the surface roughness of 3D-printed denture base and teeth polymers with conventional heat-polymerized acrylic resin to evaluate their clinical suitability. Materials and methods: Sixty cylindrical specimens (18 mm × 3 mm) were fabricated and divided into three groups: Group A – 3D-printed Denture Base Resin; Group B – 3D-printed Denture Teeth Resin; and Group C – heat-polymerized Superacryl Plus (control). Specimens were processed following standardized protocols for polishing and post-polymerization. Surface topography and roughness parameters (Ra, Rq, Rmax) were measured using atomic force microscopy (AFM). Data were analyzed using descriptive statistics, and intergroup differences were assessed with the non-parametric Mann–Whitney test (p < 0.01). Results: Both 3D-printed resins exhibited higher surface roughness than the heat-polymerized control, with Group B showing the highest Ra and Rq values, followed by Group A. Rmax values followed a similar pattern (Group B: 328.84 nm; Group A: 286.83 nm; Group C: 77.93 nm). No significant differences were found between the two 3D-printed resins. Despite variations, all materials remained within clinically acceptable roughness limits, although none reached the threshold Ra of 0.2 µm. Conclusion: The present study demonstrated that conventional heat-polymerized acrylic resin exhibits significantly lower surface roughness compared to 3D-printed denture base and teeth resins. Among the 3D-printed materials, the one used for the teeth showed the highest roughness values, followed by the material for denture bases. These findings highlight the influence of manufacturing technique and material type on surface properties, which may impact microbial colonization and denture hygiene.