Joel Wright

Mr. Joel Wright

Brigham Young University
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
EHErik Hamilton
Erik Hamilton
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
JWJoel Wright
Joel Wright
Holger SchmidtHolger Schmidt
Holger Schmidt
AHAaron Hawkins
Aaron Hawkins
Optofluidic devices are capable of detecting single molecules, but greater sensitivity and specificity is desired through hydrodynamic focusing (HDF). Three-dimensional (3D) hydrodynamic focusing was implemented in 10-μm scale microchannel cross-sections made with a single sacrificial layer. HDF is achieved using buffer fluid to sheath the sample fluid, requiring four fluid ports to operate by pressure driven flow. A low-pressure chamber, or pit, formed by etching into a substrate, enables volumetric flow ratio-induced focusing at a low flow velocity. The single layer design simplifies surface micromachining and improves device yield by 1.56 times over previous work. The focusing design was integrated with optical waveguides and used in order to analyze fluorescent signals from beads in fluid flow. The implementation of the focusing scheme was found to narrow the distribution of bead velocity and fluorescent signal, giving rise to 33% more consistent signal. Reservoir effects were observed at low operational vacuum pressures and a balance between optofluidic signal variance and intensity was achieved. The implementation of the design in optofluidic sensors will enable higher detection sensitivity and sample specificity.

15 October 2019 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
EHErik Hamilton
Erik Hamilton
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
JWJoel Wright
Joel Wright
WPWilliam G. Pitt
William G. Pitt
HSHolger Schmidt
Holger Schmidt
AHAaron R. Hawkins
Aaron R. Hawkins

24 February 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
JWJoel Wright
Joel Wright
MAMd Nafiz Amin
Md Nafiz Amin
GMGopikrishnan G. Meena
Gopikrishnan G. Meena
Holger SchmidtHolger Schmidt
Holger Schmidt
AHAaron Hawkins
Aaron Hawkins
We present a model and simulation for predicting the detected signal of a fluorescence-based optical biosensor built from optofluidic waveguides. Typical applications include flow experiments to determine pathogen concentrations in a biological sample after tagging relevant DNA or RNA sequences. An overview of the biosensor geometry and fabrication processes is presented. The basis for the predictive model is also outlined. The model is then compared to experimental results for three different biosensor designs. The model is shown to have similar signal statistics as physical tests, illustrating utility as a pre-fabrication design tool and as a predictor of detection sensitivity.

28 January 2021 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
GMGopikrishnan Gopalakrishnan Meena
Gopikrishnan Gopalakrishnan Meena
JWJoel Wright
Joel Wright
AHAaron Hawkins
Aaron Hawkins
Holger SchmidtHolger Schmidt
Holger Schmidt
High sensitivity and easy integration with microfabrication techniques has made silicon photonics one of the leading technologies used to build biosensors for diagnostic applications. Here we introduce a new silicon dioxide based optofluidic platform having a planar solid-core (SC) waveguide orthogonally intersecting a liquid-core (LC) waveguide with high refractive index ZnI 2 salt solution as core. This enables both more uniform collection of particle fluorescence by the core mode and its propagation to an off-chip detector. This approach results in ultra-high sensitivity performance, demonstrated by achieving 8X enhancement in signal-to-noise ratio, a 45x increase in detection efficiency, and a 100x lower detection limit of 80 aM of fluorescent nanobeads. This represents a key step towards an ultrasensitive biosensor system for analyzing pathogens at clinical concentrations.

29 July 2020 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
JWJoel Wright
Joel Wright
Holger SchmidtHolger Schmidt
Holger Schmidt
AHAaron Hawkins
Aaron Hawkins
Silica waveguides are often etched by reactive ion etch (RIE) processes. These processes can leave residual topography that can increase optical loss. We investigated the relation between optical loss and various RIE etch. A wet etch step meant to remove microstructures was also considered and compared. Ridge waveguides were fabricated in plasma enhanced chemical vapor deposited films by three different RIE processes, each with a different gas composition, pressure setting, and applied power setting. Half of each set of waveguides were also subjected to a hydrofluoric acid (HF) solution. The waveguides were tested for optical transmission via the cutback method. The transmission vs waveguide length measurements were plotted to fit an exponential curve and the optical loss and measurement uncertainty for each waveguide set was calculated. Clear distinctions in optical loss were found between the different RIE processes. The HF treatment also has an effect, significantly reducing optical loss for two processes and increasing it for the third. Of the tested RIE processes, one can be suggested for silica waveguides. It results in the lowest optical loss and coincidently has the fastest etch rate.

7 July 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
JWJoel Wright
Joel Wright
MAMd Nafiz Amin
Md Nafiz Amin
Holger SchmidtHolger Schmidt
Holger Schmidt
AHAaron Hawkins
Aaron Hawkins
Optofluidic flow-through biosensors are being developed for single particle detection, particularly as a tool for pathogen diagnosis. The sensitivity of the biosensor chip depends on design parameters, illumination format (side vs. top), and flow configuration (parabolic, two- and three-dimensional hydrodynamic focused (2DHF and 3DHF)). We study the signal differences between various combinations of these design aspects. Our model is validated against a sample of physical devices. We find that side-illumination with 3DHF produces the strongest and consistent signal, but parabolic flow devices process a sample volume more quickly. Practical matters of optical alignment are also discussed, which may affect design choice.