Vahid Ganjalizadeh

Vahid Ganjalizadeh

Auto-generated profile, based on publicly available information

Vahid Ganjalizadeh

School of Engineering, University of California, Santa Cruz, Santa Cruz, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
GMGopikrishnan G. Meena
Gopikrishnan G. Meena
MSMatthew A. Stott
Matthew A. Stott
AHAaron R. Hawkins
Aaron R. Hawkins
Holger SchmidtHolger Schmidt
Holger Schmidt
Multiplexed detection of biomarkers in real-time is crucial for sensitive and accurate diagnosis at the point of use. This scenario poses tremendous challenges for detection and identification of signals of varying shape and quality at the edge of the signal-to-noise limit. Here, we demonstrate a robust target identification scheme that utilizes a Deep Neural Network (DNN) for multiplex detection of single particles and molecular biomarkers. The model combines fast wavelet particle detection with Short-Time Fourier Transform analysis, followed by DNN identification on an AI-specific edge device (Google Coral Dev board). The approach is validated using multi-spot optical excitation of Klebsiella Pneumoniae bacterial nucleic acids flowing through an optofluidic waveguide chip that produces fluorescence signals of varying amplitude, duration, and quality. Amplification-free 3× multiplexing in real-time is demonstrated with excellent specificity, sensitivity, and a classification accuracy of 99.8%. These results show that a minimalistic DNN design optimized for mobile devices provides a robust framework for accurate pathogen detection using compact, low-cost diagnostic devices.

24 February 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
GMGopikrishnan G. Meena
Gopikrishnan G. Meena
TWThomas A. Wall
Thomas A. Wall
MSMatthew A. Stott
Matthew A. Stott
AHAaron R. Hawkins
Aaron R. Hawkins
Holger SchmidtHolger Schmidt
Holger Schmidt
Many sensors operate by detecting and identifying individual events in a time-dependent signal which is challenging if signals are weak and background noise is present. We introduce a powerful, fast, and robust signal analysis technique based on a massively parallel continuous wavelet transform (CWT) algorithm. The superiority of this approach is demonstrated with fluorescence signals from a chip-based, optofluidic single particle sensor. The technique is more accurate than simple peak-finding algorithms and several orders of magnitude faster than existing CWT methods, allowing for real-time data analysis during sensing for the first time. Performance is further increased by applying a custom wavelet to multi-peak signals as demonstrated using amplification-free detection of single bacterial DNAs. A 4x increase in detection rate, a 6x improved error rate, and the ability for extraction of experimental parameters are demonstrated. This cluster-based CWT analysis will enable high-performance, real-time sensing when signal-to-noise is hardware limited, for instance with low-cost sensors in point of care environments.

1 October 2024 in APL Photonics
Verified
Journal Article
Open access
PDF file
MAMd Nafiz Amin
Md Nafiz Amin
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
TATyler J. Adams
Tyler J. Adams
PDPorter B. Dixon
Porter B. Dixon
ZWZoe Weber
Zoe Weber
Holger SchmidtHolger Schmidt
Holger Schmidt
Spectral analysis of light is one of the oldest and most versatile scientific methods and the basis of countless techniques and instruments. Miniaturized spectrometers have recently seen great advances, but challenges remain before they are widely deployed. We report an integrated photonic spectrometer that achieves high performance with minimal component complexity by combining imaging of light propagation patterns in multi-mode interference waveguides with machine learning analysis. We demonstrate broadband operation in the visible and near-infrared, 0.05 nm spectral resolution, and an array of four spectrometers on a single chip. Two canonical applications are implemented: spectral analysis of the solar spectrum with neural network reconstruction and detection of Rayleigh scattering from microbeads on an optofluidic chip using principal component classification. These results illustrate the potential of this approach for high-performance spectroscopy across disciplines.

27 March 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
EHErik Hamilton
Erik Hamilton
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
JWJoel Wright
Joel Wright
Holger SchmidtHolger Schmidt
Holger Schmidt
AHAaron Hawkins
Aaron Hawkins
Optofluidic devices are capable of detecting single molecules, but greater sensitivity and specificity is desired through hydrodynamic focusing (HDF). Three-dimensional (3D) hydrodynamic focusing was implemented in 10-μm scale microchannel cross-sections made with a single sacrificial layer. HDF is achieved using buffer fluid to sheath the sample fluid, requiring four fluid ports to operate by pressure driven flow. A low-pressure chamber, or pit, formed by etching into a substrate, enables volumetric flow ratio-induced focusing at a low flow velocity. The single layer design simplifies surface micromachining and improves device yield by 1.56 times over previous work. The focusing design was integrated with optical waveguides and used in order to analyze fluorescent signals from beads in fluid flow. The implementation of the focusing scheme was found to narrow the distribution of bead velocity and fluorescent signal, giving rise to 33% more consistent signal. Reservoir effects were observed at low operational vacuum pressures and a balance between optofluidic signal variance and intensity was achieved. The implementation of the design in optofluidic sensors will enable higher detection sensitivity and sample specificity.

17 August 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
TWThomas Wall
Thomas Wall
JMJohnny McMurray
Johnny McMurray
GMGopikrishnan Meena
Gopikrishnan Meena
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
Holger SchmidtHolger Schmidt
Holger Schmidt
AHAaron Hawkins
Aaron Hawkins
Optofluidic, lab-on-a-chip fluorescence sensors were fabricated using buried anti-resonant reflecting optical waveguides (bARROWs). The bARROWs are impervious to the negative water absorption effects that typically occur in waveguides made using hygroscopic, plasma-enhanced chemical vapor deposition (PECVD) oxides. These sensors were used to detect fluorescent microbeads and had an average signal-to-noise ratio (SNR) that was 81.3% higher than that of single-oxide ARROW fluorescence sensors. While the single-oxide ARROW sensors were annealed at 300 °C to drive moisture out of the waveguides, the bARROW sensors required no annealing process to obtain a high SNR.

11 September 2018 in Optics Letters
Verified
Journal Article
Open access
PDF file
JBJennifer A. Black
Jennifer A. Black
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
JPJoshua W. Parks
Joshua W. Parks
HSHolger Schmidt
Holger Schmidt
Liquid-core waveguide-based optofluidic devices have proven to be valuable tools for analysis of biological samples in fluid. They have enabled single bioparticle sensitivity while maintaining in-plane detection via light-induced fluorescence. The incorporation of multi-spot excitation with multimode interference (MMI) waveguides has enabled spatially and spectrally multiplexed detection of single viruses on an oxide-based optofluidic platform. Here, we introduce a new way of MMI-based multiplexing where multiple analysis channels are placed within a single multi-spot pattern. This stacked channel design enables both velocity and spectral multiplexing of single particles. The principle is demonstrated with differentiated detection of single H3N2 and H1N1 viruses on a polydimethylsiloxane platform.