This work presents an innovative and sustainable approach to remove NO emissions from urban ambient air in confined areas (underground parking areas or tunnels) using low-cost activated carbons obtained from Miscanthus biochar (MSP700) by physical activation (with CO2 or steam) at temperatures ranging from 800 to 900 °C. The NO removal capacity of the activated biochars was evaluated under different conditions (temperature, humidity and oxygen concentration) and compared against a commercial activated carbon. This last material showed a clear dependence on oxygen concentration and temperature, exhibiting a maximum capacity of 72.6% in air at 20 °C, whilst, its capacity notably decreased at higher temperatures, revealing that physical NO adsorption is the limiting step for the commercial sample that presents limited oxygen surface functionalities. In contrast, MSP700-activated biochars reached nearly complete NO removal (99.9%) at all tested temperatures in air ambient. Those MSP700-derived carbons only required low oxygen concentration (4 vol%) in the gas stream to achieve the full NO removal at 20 °C. Moreover, they also showed an excellent performance in the presence of H2O, reaching NO removal higher than 96%. This remarkable activity results from the abundance of basic oxygenated surface groups, which act as active sites for NO/O2 adsorption, along with the presence of a homogeneous microporosity of 6 Å, which enables intimate contact between NO and O2. These features promote the oxidation of NO to NO2, which is further retained over the carbon surface. Therefore, the activated biochars studied here could be considered promising materials for the efficient removal of NO at low concentrations from air at moderate temperatures, thus closely approaching real-life conditions in confined spaces.
Indoor air quality (IAQ) significantly impacts human health, particularly in enclosed spaces where people spend most of their time. This study evaluates the performance of low-cost IAQ sensors, focusing on their ability to measure carbon dioxide (CO2) and particulate matter (PM) under real-world conditions. Measurements provided by these sensors were verified against calibrated reference equipment. The study utilized two commercial devices from inBiot and Kaiterra, comparing their outputs to a reference sensor across a range of CO2 concentrations (500–1200 ppm) and environmental conditions (21–25 °C, 27–92% RH). Data were analyzed for relative error, temporal stability, and reproducibility. Results indicate strong correlation between low-cost sensors (LCSs) and the reference sensor at lower CO2 concentrations, with minor deviations at higher levels. Environmental conditions had minimal impact on sensor performance, highlighting robustness to temperature and humidity within the tested ranges. For PM measurements, low-cost sensors effectively tracked trends, but inaccuracies increased with particle concentration. Overall, these findings support the feasibility of using low-cost sensors for non-critical IAQ monitoring, offering an affordable alternative for tracking CO2 and PM trends. Additionally, LCSs can assess long-term exposure to contaminants, providing insights into potential health risks and useful information for non-expert users.
Indoor air quality (IAQ) is influenced by a wide range of chemical, biological and physical agents that can negatively impact physical, immunological and mental health. Adverse health effects depend on the type and concentration of pollutants, duration of exposure, and individual susceptibility. The availability of data on IAQ is limited, as are standardized approaches for evaluating its health impact. This expert review aims to describe the most important indoor air determinants affecting health, and present the IDEAL cluster, which comprises seven EU‐funded scientific projects on the topic of IAQ and human health. Across the IDEAL projects, knowledge is generated on exposure to a wide range of indoor air pollutants, including well‐known hazards and more explorative chemical and microbiological determinants. The projects will also contribute to the implementation of low‐cost and/or real‐time sensors on IAQ, as well as advanced chemical and microbiological analyses, and evaluate various interventions to improve IAQ. Several of them focus on particularly vulnerable groups. Raising public awareness and implementing measures to reduce pollutant levels are essential for safeguarding health, particularly in urban areas with elevated pollution levels.
31 July 2021 in International Journal of Energy Production and Management
Climate change impacts particularly affect vulnerable populations such as children. Therefore, addressing the adaptation of educational buildings is...
Welcome to the WIT Press eLibrary - the home of the Transactions of the Wessex Institute collection, providing on-line access to papers presented at the Institute's prestigious international conferences and from its State-of-the-Art in Science & Engineering publications.