The wide application of anaerobic digestion for the treatment of organic waste streams and high-loaded wastewater results in the production of high quantities of anaerobic effluents. Such effluents are characterised by high nutrient content, this is why struvite crystallisation and ammonia stripping have gained interest as routes to nitrogen and phosphorus recovery. Pros and cons of both technologies have been analysed in this paper. Ammonia stripping coupled with absorption proved to be a suitable technical solution for the recovery and valorisation of the nitrogen contained in waste streams. Laboratory-scale experiments result in more than 80% of ammonia recovery using this technique. However, since the crystallisation process can simultaneously remove and recover more than 90% P and N in stoichiometric ratio (according struvite formulation) from waste streams, it is considered the preferred technique. Both processes are environmentally friendly and cost-effective in large-scale facilities although economics slightly favour the struvite formation.
Phase change materials are capable of storing and releasing energy in the form of heat in determined temperature ranges, so to increase a building’s thermal inertia, stabilize its indoor temperatures and reduce its energetic demand. Therefore, if we used these materials we could have more energetically efficient buildings. Nevertheless, are these materials most appropriate to be used in buildings? Could the incorporation of phase change materials in buildings with concrete structures be generalized? This article aims to carry out a review of these phase change materials from construction professionals’ points of view, study their applications for buildings with reinforced concrete structures and the key points for these applications, draw conclusions and provide recommendations useful for all professionals within the sector who are considering the application of these materials.
1 April 1996 in International Journal of Numerical Methods for Heat & Fluid Flow
In this article, an analytical model is presented for the simulation of the thermal behaviour of dams that are subjected to environmental thermal action during service. The method of solution adopted, as well as the evaluation of the different parameters, is described in detail. Also, the theoretical results that are predicted by the model are compared with experimental results obtained through the monitoring of temperature in several dams in Spain. The dams considered are currently in use, of different types and in distinct locations.
Indoor air quality (IAQ) significantly impacts human health, particularly in enclosed spaces where people spend most of their time. This study evaluates the performance of low-cost IAQ sensors, focusing on their ability to measure carbon dioxide (CO2) and particulate matter (PM) under real-world conditions. Measurements provided by these sensors were verified against calibrated reference equipment. The study utilized two commercial devices from inBiot and Kaiterra, comparing their outputs to a reference sensor across a range of CO2 concentrations (500–1200 ppm) and environmental conditions (21–25 °C, 27–92% RH). Data were analyzed for relative error, temporal stability, and reproducibility. Results indicate strong correlation between low-cost sensors (LCSs) and the reference sensor at lower CO2 concentrations, with minor deviations at higher levels. Environmental conditions had minimal impact on sensor performance, highlighting robustness to temperature and humidity within the tested ranges. For PM measurements, low-cost sensors effectively tracked trends, but inaccuracies increased with particle concentration. Overall, these findings support the feasibility of using low-cost sensors for non-critical IAQ monitoring, offering an affordable alternative for tracking CO2 and PM trends. Additionally, LCSs can assess long-term exposure to contaminants, providing insights into potential health risks and useful information for non-expert users.