Jun Wang

Prof. Dr. Jun Wang

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Dong LiuDong Liu
Dong Liu
NLNa Liu
Na Liu
DRDonglin Ren
Donglin Ren
XWXiaozhou Wu
Xiaozhou Wu
Jun WangJun Wang
Jun Wang
JWJialan Wen
Jialan Wen
The thermal comfort of preschool children was assumed to be similar to that of young adults, which may cause inaccuracy. This study tested and analyzed the thermal response characteristics of young adults and preschool children (4–6 years old) and the differences in thermal sensation and thermal physiology between the two groups of participants in a room with a radiant floor heating system using the difference analysis methods (the paired data t-test, the Mann–Whitney U test and the Kruskal–Wallis H test). Participants were divided into two groups, young adults and preschoolers, and were sat in each condition while wearing winter clothing with a thermal resistance of 1.02 clo. The results showed that when the indoor temperature changed, there was a significant difference in the local skin temperature of the calf between the two groups of participants (p < 0.05). Preschool children adapt to the thermal environment better than adults, and the difference in metabolic rate is one of the influencing factors. The overall thermal sensation with mean skin temperature of the different populations was linearly correlated; correlation coefficients were 0.944 and 0.932, respectively. The overall thermal sensation of the participants was linear with respect to the indoor operative temperature. Preschool children have a higher thermal sensitivity to temperature change than young adults under low-temperature radiant floor heating systems, indicating that children have different thermal awareness from adults. There were significant differences in preschoolers’ subjective assessments of thermal sensation when the predicted mean vote (PMV) model was used as the evaluation standard; the difference ranged from 0.77 to 2.33. Thus, the PMV-predicted percentage dissatisfied (PPD) model is not suitable for preschool children.

1 October 2019 in Journal of Thermal Science
Verified
Journal Article
Closed access
PDF file
JYJie Yang
Jie Yang
Jun WangJun Wang
Jun Wang
FXFeng Xiong
Feng Xiong
HLHao Liang
Hao Liang
YLYunzhang Li
Yunzhang Li

8 January 2026 in Frontiers in Built Environment
Verified
Journal Article
Open access
PDF file
Jun WangJun Wang
Jun Wang
QWQi Wang
Qi Wang
TWTingting Wang
Tingting Wang
Under the dual effects of outdoor ozone (O 3 ) pollution intrusion and indoor pollution source generation, the formation mechanism, characterization, prevention and control methods of indoor O 3 pollution have been one important scientific issue in the field of indoor air quality (IAQ) research. To have a systematic understanding of this issue, this study summarizes the trends and hotspots of indoor ozone pollution research, systematically reviews the sources, hazards, and characteristics of indoor ozone pollution and analyzes the different prevention and control methods of indoor ozone pollution, including active and passive ozone removal technologies. On this basis, the engineering applications of indoor ozone pollution prevention and control methods in residential, educational, and commercial scenarios are further discussed. Furthermore, the development trends and technical challenges of indoor ozone pollution prevention and control are pointed out. The development of efficient and low-cost ozone removal materials, the optimization of intelligent monitoring systems, and integrated pollution control strategies adapted to climate change should be focused on in the future, in order to provide healthier and safer indoor air environment. The insights could inform designers, engineers, and policymakers seeking to integrate ozone-responsive strategies into building ventilation, material selection, IAQ management, and air-cleaning systems.

31 August 2022
Verified
Conference Paper
Open access
PDF file
LJLijun Jing
Lijun Jing
Jun WangJun Wang
Jun Wang
Ozone exposure has been proven to be strongly associated with both morbidity and mortality. In addition, the reaction of ozone with human skin sebum, building materials and indoor other compounds can cause secondary pollution of indoor environment. Therefore, how to effectively control indoor ozone pollution and its induced secondary pollution is an important scientific problem that needs to be solved in the field of indoor air quality. PRM (passive removal materials) can passively remove indoor ozone without energy consumption. According to the mechanism of ozone removal on PRM surface, the effects of material area, reaction probability, transport-limited deposition velocity, outdoor ozone concentration, air change rate (ACH) and indoor reaction rate on ozone removal rate of PRM were analyzed in this study. The results show that the ozone removal rate of PRM is greatly influenced by the reaction probability, the ACH, the surface area and the transport-limited deposition velocity, while the indoor reaction rate and outdoor ozone concentration have no obvious influence. Therefore, in order to remove more indoor ozone by PRM, the position and area of PRM with different reaction probabilities should be chosen reasonably.

31 August 2022
Verified
Conference Paper
Open access
PDF file
LJLijun Jing
Lijun Jing
Jun WangJun Wang
Jun Wang
Ozone pollution can not only cause serious effects on human respiratory tract, lung, cardiovascular and immune system, but also lead to secondary pollution of indoor air environment by reacting with human surface sebum, building materials surface and other indoor compounds. As people stay indoors for more than 90% of their time, indoor ozone exposure is far more harmful than outdoor ozone exposure. Indoor ozone mainly comes from the outdoor environment. Therefore, it is an important prerequisite for controlling indoor ozone pollution to master the characteristics of indoor ozone pollution concentration under the influence of outdoor air pollution. The outdoor ozone concentration of 20 representative cities in the five climatic areas of China were investigated in this study. Meanwhile, indoor ozone concentration was predicted based on I/O ratio (indoor-outdoor concentration ratio). Furthermore, the indoor ozone pollution level affected by window opening time, air change rate and ozone deposition velocity was analyzed. The results show that the increase of air change rate and window opening time leads to the rise of indoor ozone pollution level. Moreover, the growing up of ozone deposition velocity may cause more ozone to be removed by the indoor surface, then the indoor ozone concentration decreases. In addition, indoor ozone pollution is the most serious in cold zone and the least serious in mild zone.

7 October 2015 in Procedia Engineering
Verified
Journal Article
Open access
PDF file
Jun WangJun Wang
Jun Wang
YCYong Chen
Yong Chen
SWSuo Wang
Suo Wang
Ozone reactions with human surfaces (skin, hair, and clothing) are an important source of volatile organic compounds in the indoor air, which play an important role in indoor air quality and building occupant health. It's the purpose of this study to obtain the characteristics of air change rate (ACH) and reactants concentration impacting human surface chemical reaction, which is very necessary and meaningful for guiding how to improve indoor air quality (IAQ). Theoretical model describing indoor human surface chemical reaction between O3 and Squalene, heat and mass transfer was established and verified. Meanwhile, three kinds of factors were taken into account and their influence on human surface chemical reaction under displacement ventilation was analyzed for typical building space. The results show that the rising of ACH is benefit for reducing the exposure concentration of product (secondary pollutant) under displacement ventilation. Moreover, lowering ozone concentration in supplied air and squalene concentration in human surface is very meaningful for improving IAQ.