Justus Groß

Prof. Dr. Justus Groß

Department of General- Visceral-, Thoracic-, Vascular - and Transplantation Surgery, Universitätsmedizin Rostock, Rostock, Mecklenburg-Western Pomerania, Germany
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2023 in Viruses
Verified
Journal Article
Open access
PDF file
CWChristian Willy
Christian Willy
JBJoachim J. Bugert
Joachim J. Bugert
ACAnnika Y. Classen
Annika Y. Classen
LDLi Deng
Li Deng
ADAnja Düchting
Anja Düchting
FBFelix Bröcker
Felix Bröcker
Bacteriophage therapy holds promise in addressing the antibiotic-resistance crisis, globally and in Germany. Here, we provide an overview of the current situation (2023) of applied phage therapy and supporting research in Germany. The authors, an interdisciplinary group working on patient-focused bacteriophage research, addressed phage production, phage banks, susceptibility testing, clinical application, ongoing translational research, the regulatory situation, and the network structure in Germany. They identified critical shortcomings including the lack of clinical trials, a paucity of appropriate regulation and a shortage of phages for clinical use. Phage therapy is currently being applied to a limited number of patients as individual treatment trials. There is presently only one site in Germany for large-scale good-manufacturing-practice (GMP) phage production, and one clinic carrying out permission-free production of medicinal products. Several phage banks exist, but due to varying institutional policies, exchange among them is limited. The number of phage research projects has remarkably increased in recent years, some of which are part of structured networks. There is a demand for the expansion of production capacities with defined quality standards, a structured registry of all treated patients and clear therapeutic guidelines. Furthermore, the medical field is still poorly informed about phage therapy. The current status of non-approval, however, may also be regarded as advantageous, as insufficiently restricted use of phage therapy without adequate scientific evidence for effectiveness and safety must be prevented. In close coordination with the regulatory authorities, it seems sensible to first allow some centers to treat patients following the Belgian model. There is an urgent need for targeted networking and funding, particularly of translational research, to help advance the clinical application of phages.

27 September 2022 in Antibiotics
Verified
Journal Article
Open access
PDF file
APAnja Pueschel
Anja Pueschel
RSRomy Skusa
Romy Skusa
ABAntonia Bollensdorf
Antonia Bollensdorf
Justus GroßJustus Groß
Justus Groß
Drive line infections (DLI) are common infectious complications after left ventricular assist devices (LVAD) implantation. In case of severe or persistent infections, when conservative management fails, the exchange of the total LVAD may become necessary. We present a case of successful treatment of DL infection with a combination of antibiotics, debridement and local bacteriophage treatment.

3 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
AHAndra Heinrich
Andra Heinrich
Felix StreckenbachFelix Streckenbach
Felix Streckenbach
EBEbba Beller
Ebba Beller
Justus GroßJustus Groß
Justus Groß
MWMarc André Weber
Marc André Weber
FMFelix G. Meinel
Felix G. Meinel
To evaluate the impact of a novel, deep-learning-based image reconstruction (DLIR) algorithm on image quality in CT angiography of the aorta, we retrospectively analyzed 51 consecutive patients who underwent ECG-gated chest CT angiography and non-gated acquisition for the abdomen on a 256-dectector-row CT. Images were reconstructed with adaptive statistical iterative reconstruction (ASIR-V) and DLIR. Intravascular image noise, the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were quantified for the ascending aorta, the descending thoracic aorta, the abdominal aorta and the iliac arteries. Two readers scored subjective image quality on a five-point scale. Compared to ASIR-V, DLIR reduced the median image noise by 51–54% for the ascending aorta and the descending thoracic aorta. Correspondingly, median CNR roughly doubled for the ascending aorta and descending thoracic aorta. There was a 38% reduction in image noise for the abdominal aorta and the iliac arteries, with a corresponding improvement in CNR. Median subjective image quality improved from good to excellent at all anatomical levels. In CT angiography of the aorta, DLIR substantially improved objective and subjective image quality beyond what can be achieved by state-of-the-art iterative reconstruction. This can pave the way for further radiation or contrast dose reductions.

29 April 2022 in Antibiotics
Verified
Journal Article
Open access
PDF file
Sebastian V. RojasSebastian V. Rojas
Sebastian V. Rojas
SJSimon F Junghans
Simon F Junghans
HFHenrik Fox
Henrik Fox
KLKanstantsin Lazouski
Kanstantsin Lazouski
RSRene Schramm
Rene Schramm
Justus GroßJustus Groß
Justus Groß
We report a case of severe outflow graft infection following left ventricular assist device (LVAD) implantation. A 51-year old male LVAD patient was readmitted to our hospital presenting signs of systemic infection. One year previously, LVAD implantation (HeartMate3, Abbott, Chicago, IL, USA) with concomitant patent foramen ovale closure had been performed in the context of end-stage heart failure due to dilative cardiomyopathy (INTERMACS III). The indication for LVAD-therapy was bridge-to-candidacy, since the patient did not instantly fulfill all criteria for cardiac transplantation. At admission, a PET-CT scan unveiled fluid accumulation, encircling the outflow-graft prosthesis (SUVmax 10.5) with contrast-enhancement involving the intrathoracic driveline (SUVmax 11.2). Since cardiac transplantation was not feasible, the patient underwent surgical revision. In the first step, redo sternotomy was performed with local debridement, including jet lavage. Intraoperative swabs confirmed bacterial infection with staphylococcus aureus. Following this, the patient underwent negative pressure wound therapy (NPWT) with instillation using the V.A.C. VERAFLO system (KCI-3M, San Antonio, TX, USA) for a total of 19 days. Due to the severity of infection, local bacteriophage application was performed within the wound closure. In order to concentrate phage therapy at the infection site, phages were applied using a novel semi-fluid galenic. After wound closure, the patient was discharged with an uneventful course. A control PET-CT scan 3 months after discharge showed a significant decrease in infection (outflow graft: SUVmax 7.2, intrathoracic driveline: SUVmax 3.0) correlated with contrast enhancement. Bacterial infection of intrathoracic VAD components represents a severe and potentially life-threatening complication. If cardiac transplantation is not feasible, complex wound management strategies are required. Local bacteriophage therapy might be a promising addition to already established therapeutical options. In order to improve bacteriophage retention at the wound site, application of a viscous galenic might be beneficial.

30 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EGEberhard Grambow
Eberhard Grambow
NSNiels Arne Sandkühler
Niels Arne Sandkühler
Justus GroßJustus Groß
Justus Groß
Daniel ThiemDaniel Thiem
Daniel Thiem
MDMichael Dau
Michael Dau
MWMalte Weinrich
Malte Weinrich
Background: Assessment of tissue oxygenation is an important aspect of detection and monitoring of patients with peripheral artery disease (PAD). Hyperspectral imaging (HSI) is a non-contact technology for assessing microcirculatory function by quantifying tissue oxygen saturation (StO2). This study investigated whether HSI can be used to monitor skin oxygenation in patients with PAD after appropriate treatment of the lower extremities. Methods: For this purpose, 37 patients with PAD were studied by means of ankle–brachial index (ABI) and HSI before and after surgical or endovascular therapy. Thereby, the oxygenation parameter StO2 and near infrared (NIR) perfusion index were quantified in seven angiosomes on the diseased lower leg and foot. In addition, the effects of skin temperature and physical activity on StO2 and the NIR perfusion index and the respective inter-operator variability of these parameters were investigated in 25 healthy volunteers. Results: In all patients, the ABI significantly increased after surgical and endovascular therapy. In parallel, HSI revealed significant changes in both StO2 and NIR perfusion index in almost all studied angiosomes depending on the performed treatment. The increase in tissue oxygenation saturation was especially pronounced after surgical treatment. Neither heat nor cold, nor physical activity, nor repeated assessments of HSI parameters by independent investigators significantly affected the results on StO2 and the NIR perfusion index. Conclusions: Tissue oxygen saturation data obtained with HSI are robust to external confounders, such as temperature and physical activity, and do not show inter-operator variability; therefore, can be used as an additional technique to established methods, such as the ABI, to monitor peripheral perfusion in patients with PAD.

14 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
CSChristopher Skusa
Christopher Skusa
RSRomy Skusa
Romy Skusa
MWMoritz Wohlfarth
Moritz Wohlfarth
PWPhilipp Warnke
Philipp Warnke
APAndreas Podbielski
Andreas Podbielski
FMFelix G. Meinel
Felix G. Meinel
The aim of this investigation was to evaluate predictive CT imaging features and clinical parameters to distinguish infected from sterile fluid collections. Detection of infectious agents by advanced microbiological analysis was used as the reference standard. From April 2018 to October 2019, all patients undergoing CT-guided drainages were prospectively enrolled, if drainage material volume was at least 5 mL. Univariate analysis revealed attenuation (p = 0.001), entrapped gas (p < 0.001), fat stranding (p < 0.001), wall thickness (p < 0.001) and enhancement (p < 0.001) as imaging biomarkers and procalcitonin (p = 0.003) as clinical predictive parameters for infected fluid collections. On multivariate analysis, attenuation > 10 HU (p = 0.038), presence of entrapped gas (p = 0.027) and wall enhancement (p = 0.028) were independent parameters for distinguishing between infected and non-infected fluids. Gas entrapment had high specificity (93%) but low sensitivity (48%), while wall enhancement had high sensitivity (91%) but low specificity (50%). CT attenuation > 10 HU showed intermediate sensitivity (74%) and specificity (70%). Evaluation of the published proposed scoring systems did not improve diagnostic accuracy over independent predictors in our study. In conclusion, this prospective study confirmed that CT attenuation > 10 HU, entrapped gas and wall enhancement are the key imaging features to distinguish infected from sterile fluid collections on CT.