31 May 2016 in Scoliosis and Spinal Disorders
Verified
Journal Article
Open access
PDF file
YZY.P. Zheng
Y.P. Zheng
Timothy Tin Yan LeeTimothy Tin Yan Lee
Timothy Tin Yan Lee
KLKa Lai
Ka Lai
BYBenjamin Hon-Kei Yip
Benjamin Hon-Kei Yip
GZGuang-Quan Zhou
Guang-Quan Zhou
TLTsz-Ping Lam
Tsz-Ping Lam
Radiographic evaluation for patients with scoliosis using Cobb method is the current gold standard, but radiography has radiation hazards. Several groups have recently demonstrated the feasibility of using 3D ultrasound for the evaluation of scoliosis. Ultrasound imaging is radiation-free, comparatively more accessible, and inexpensive. However, a reliable and valid 3D ultrasound system ready for clinical scoliosis assessment has not yet been reported. Scolioscan is a newly developed system targeted for scoliosis assessment in clinics by using coronal images of spine generated by a 3D ultrasound volume projection imaging method. The aim of this study is to test the reliability of spine deformity measurement of Scolioscan and its validity compared to the gold standard Cobb angle measurements from radiography in adolescent idiopathic scoliosis (AIS) patients. Prospective study divided into two stages: 1) Investigation of intra- and inter- reliability between two operators for acquiring images using Scolioscan and among three raters for measuring spinal curves from those images; 2) Correlation between the Cobb angle obtained from radiography by a medical doctor and the spine curve angle obtained using Scolioscan (Scolioscan angle). The raters for ultrasound images and the doctors for evaluating radiographic images were mutually blinded. The two stages of tests involved 20 (80 % females, total of 26 angles, age of 16.4 ± 2.7 years, and Cobb angle of 27.6 ± 11.8°) and 49 (69 % female, 73 angles, 15.8 ± 2.7 years and 24.8 ± 9.7°) AIS patients, respectively. Intra-class correlation coefficients (ICC) and Bland-Altman plots and root-mean-square differences (RMS) were employed to determine correlations, which interpreted based on defined criteria. We demonstrated a very good intra-rater and intra-operator reliability for Scolioscan angle measurement with ICC larger than 0.94 and 0.88, respectively. Very good inter-rater and inter-operator reliability was also demonstrated, with both ICC larger than 0.87. For the thoracic deformity measurement, the RMS were 2.5 and 3.3° in the intra- and inter-operator tests, and 1.5 and 3.6° in the intra- and inter-rater tests, respectively. The RMS differences were 3.1, 3.1, 1.6, 3.7° in the intra- and inter-operator and intra- and inter-rater tests, respectively, for the lumbar angle measurement. Moderate to strong correlations (R2 > 0.72) were observed between the Scolioscan angles and Cobb angles for both the thoracic and lumbar regions. It was noted that the Scolioscan angle slightly underestimated the spinal deformity in comparison with Cobb angle, and an overall regression equation y = 1.1797x (R2 = 0.76) could be used to translate the Scolioscan angle (x) to Cobb angle (y) for this group of patients. The RMS difference between Scolioscan angle and Cobb angle was 4.7 and 6.2°, with and without the correlation using the overall regression equation. We showed that Scolioscan is reliable for measuring coronal deformity for patients with AIS and appears promising in screening large numbers of patients, for progress monitoring, and evaluation of treatment outcomes. Due to it being radiation-free and relatively low-cost, Scolioscan has potential to be widely implemented and may contribute to reducing radiation dose during serial monitoring.

24 February 2017 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GZGuang-Quan Zhou
Guang-Quan Zhou
WJWei-Wei Jiang
Wei-Wei Jiang
KLKa Lai
Ka Lai
YZY.P. Zheng
Y.P. Zheng
This paper presents an automated measurement of spine curvature by using prior knowledge on vertebral anatomical structures in ultrasound volume projection imaging (VPI). This method can be used in scoliosis assessment with free-hand 3-D ultrasound imaging. It is based on the extraction of bony features from VPI images using a newly proposed two-fold thresholding strategy, with information of the symmetric and asymmetric measures obtained from phase congruency. The spinous column profile is detected from the segmented bony regions, and it is further used to extract a curve representing spine profile. The spine curvature is then automatically calculated according to the inflection points along the curve. The algorithm was evaluated on volunteers with the different severity of scoliosis. The results obtained using the newly developed method had a good linear correlation with those by the manual method (r ≥ 0.90, p <; 0.001) and X-ray Cobb's method (r = 0.83, p <; 0.001). The bigger variations observed in the manual measurement also implied that the automatic method is more reliable. The proposed method can be a promising approach for facilitating the applications of 3-D ultrasound imaging in the diagnosis, treatment, and screening of scoliosis.

1 November 2019 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
YWYi-Shun Wong
Yi-Shun Wong
KLKa Lai
Ka Lai
YZY.P. Zheng
Y.P. Zheng
LWLyn Lee-Ning Wong
Lyn Lee-Ning Wong
BNBobby Kin-Wah Ng
Bobby Kin-Wah Ng
TLTsz-Ping Lam
Tsz-Ping Lam
Radiation exposure with repeated radiography required at follow-up poses serious health concerns for scoliosis patients. Although spinous process angle (SPA) measurement of spinal curvatures with ultrasound has been reported with promising results, an evidence-based account on its accuracy for translational application remains undefined. This prospective study involved 952 idiopathic scoliosis patients (75.7% female, mean age 16.7 ± 3.0 y, Cobb 28.7 ± 11.6°). Among 1432 curves (88.1%) detected by ultrasound, there was good correlation between radiologic Cobb angles measured manually on EOS (E_Cobb) whole-spine radiographs and automatic ultrasound SPA measurement for upper spinal curves (USCs) (r = 0.873, apices T7-T12/L1 intervertebral disc) and lower spinal curves (LSCs) (r = 0.740, apices L1 or below) (p < 0.001). Taller stature was associated with stronger correlation. For E_Cobb <30°, 66.6% USCs and 62.4% LSCs had absolute differences between E_Cobb and predicted Cobb angle calculated from SPA ≤5°. Ultrasound could be a viable option in lieu of radiography for measuring coronal curves with apices at T7 or lower and Cobb angle <30°.

19 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KLKa Lai
Ka Lai
Timothy Tin Yan LeeTimothy Tin Yan Lee
Timothy Tin Yan Lee
MLMichael Ka-Shing Lee
Michael Ka-Shing Lee
JHJoseph Chi-Ho Hui
Joseph Chi-Ho Hui
YZY.P. Zheng
Y.P. Zheng
To diagnose scoliosis, the standing radiograph with Cobb’s method is the gold standard for clinical practice. Recently, three-dimensional (3D) ultrasound imaging, which is radiation-free and inexpensive, has been demonstrated to be reliable for the assessment of scoliosis and validated by several groups. A portable 3D ultrasound system for scoliosis assessment is very much demanded, as it can further extend its potential applications for scoliosis screening, diagnosis, monitoring, treatment outcome measurement, and progress prediction. The aim of this study was to investigate the reliability of a newly developed portable 3D ultrasound imaging system, Scolioscan Air, for scoliosis assessment using coronal images it generated. The system was comprised of a handheld probe and tablet PC linking with a USB cable, and the probe further included a palm-sized ultrasound module together with a low-profile optical spatial sensor. A plastic phantom with three different angle structures built-in was used to evaluate the accuracy of measurement by positioning in 10 different orientations. Then, 19 volunteers with scoliosis (13F and 6M; Age: 13.6 ± 3.2 years) with different severity of scoliosis were assessed. Each subject underwent scanning by a commercially available 3D ultrasound imaging system, Scolioscan, and the portable 3D ultrasound imaging system, with the same posture on the same date. The spinal process angles (SPA) were measured in the coronal images formed by both systems and compared with each other. The angle phantom measurement showed the measured angles well agreed with the designed values, 59.7 ± 2.9 vs. 60 degrees, 40.8 ± 1.9 vs. 40 degrees, and 20.9 ± 2.1 vs. 20 degrees. For the subject tests, results demonstrated that there was a very good agreement between the angles obtained by the two systems, with a strong correlation (R2 = 0.78) for the 29 curves measured. The absolute difference between the two data sets was 2.9 ± 1.8 degrees. In addition, there was a small mean difference of 1.2 degrees, and the differences were symmetrically distributed around the mean difference according to the Bland–Altman test. Scolioscan Air was sufficiently comparable to Scolioscan in scoliosis assessment, overcoming the space limitation of Scolioscan and thus providing wider applications. Further studies involving a larger number of subjects are worthwhile to demonstrate its potential clinical values for the management of scoliosis.

21 December 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CHChen He
Chen He
MTMichael Kai-Tsun To
Michael Kai-Tsun To
Jason Pui Yin CheungJason Pui Yin Cheung
Jason Pui Yin Cheung
KCKenneth Cheung
Kenneth Cheung
CCChi-Kwan Chan
Chi-Kwan Chan
MWM. S. Wong
M. S. Wong
Spinal flexibility is an essential parameter for clinical decision making on the patients with adolescent idiopathic scoliosis (AIS). Various methods are proposed to assess spinal flexibility, but which assessment method is more effective to predict the effect of orthotic treatment is unclear. To investigate an effective assessment method of spinal flexibility to predict the initial in-orthosis correction, among the supine, prone, sitting with lateral bending and prone with lateral bending positions. Thirty-five patients with AIS (mean Cobb angle: 28° ± 7°; mean age: 12 ± 2 years; Risser sign: 0–2) were recruited. Before orthosis fitting, spinal flexibility was assessed by an ultrasound system in 4 positions (apart from standing) including supine, prone, sitting with lateral bending and prone with lateral bending. After orthosis fitting, the initial in-orthosis correction was routinely assessed by whole spine standing radiograph. Comparisons and correlation analyses were performed between the spinal flexibility in the 4 positions and the initial in-orthosis correction. The mean in-orthosis correction was 41% while the mean curve correction (spinal flexibility) in the 4 studied positions were 40% (supine), 42% (prone), 127% (prone with lateral bending) and 143% (sitting with lateral bending). The correlation coefficients between initial in-orthosis correction and curve correction (spinal flexibility) in the 4 studied positions were r = 0.66 (supine), r = 0.75 (prone), r = 0.03 (prone with lateral bending) and r = 0.04 (sitting with lateral bending). The spinal flexibility in the prone position is the closest to and most correlated with the initial in-orthosis correction among the 4 studied positions. Thus, the prone position could be an effective method to predict the initial effect of orthotic treatment on the patients with AIS.

1 October 2019 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
Timothy Tin Yan LeeTimothy Tin Yan Lee
Timothy Tin Yan Lee
WJWei Wei Jiang
Wei Wei Jiang
CCConnie Lok Kan Cheng
Connie Lok Kan Cheng
KLKa Lai
Ka Lai
MTMichael Kai Tsun To
Michael Kai Tsun To
YZY.P. Zheng
Y.P. Zheng