Kamil Sylwester Stasiak

Mr. Kamil Sylwester Stasiak

Gdańsk University of Technology
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
PZPaweł Ziółkowski
Paweł Ziółkowski
Pawel MadejskiPawel Madejski
Pawel Madejski
MAMilad Amiri
Milad Amiri
TKTomasz Kuś
Tomasz Kuś
KSKamil Sylwester Stasiak
Kamil Sylwester Stasiak
DMDariusz Mikielewicz
Dariusz Mikielewicz
The article presents results of thermodynamic analysis using a zero-dimensional mathematical models of a negative CO2 emission power plant. The developed cycle of a negative CO2 emission power plant allows the production of electricity using gasified sewage sludge as a main fuel. The negative emission can be achieved by the use this type of fuel which is already a “zero-emissive” energy source. Together with carbon capture installation, there is a possibility to decrease CO2 emission below the “zero” level. Developed models of a novel gas cycle which use selected codes allow the prediction of basic parameters of thermodynamic cycles such as output power, efficiency, combustion composition, exhaust temperature, etc. The paper presents results of thermodynamic analysis of two novel cycles, called PDF0 and PFD1, by using different thermodynamic codes. A comparison of results obtained by three different codes offered the chance to verify results because the experimental data are currently not available. The comparison of predictions between three different software in the literature is something new, according to studies made by authors. For gross efficiency (54.74%, 55.18%, and 52.00%), there is a similar relationship for turbine power output (155.9 kW, 157.19 kW, and 148.16 kW). Additionally, the chemical energy rate of the fuel is taken into account, which ultimately results in higher efficiencies for flue gases with increased steam production. A similar trend is assessed for increased CO2 in the flue gas. The developed precise models are particularly important for a carbon capture and storage (CCS) energy system, where relatively new devices mutually cooperate and their thermodynamic parameters affect those devices. Proposed software employs extended a gas–steam turbine cycle to determine the effect of cycle into environment. First of all, it should be stated that there is a slight influence of the software used on the results obtained, but the basic tendencies are the same, which makes it possible to analyze various types of thermodynamic cycles. Secondly, the possibility of a negative CO2 emission power plant and the positive environmental impact of the proposed solution has been demonstrated, which is also a novelty in the area of thermodynamic cycles.

9 January 2024 in Journal of Energy Resources Technology
Verified
Journal Article
Open access
PDF file
KSKamil Sylwester Stasiak
Kamil Sylwester Stasiak
PZPaweł Ziółkowski
Paweł Ziółkowski
DMDariusz Mikielewicz
Dariusz Mikielewicz
The study aims to investigate the application of the organic Rankine cycle (ORC) in the bioenergy with carbon capture and storage (BECCS) using gasification of sewage sludge. The tool used in the investigation is the aspen plus software with refprop property methods for calculating fluid properties. The reason for this study is that a detailed analysis of the proposed BECCS process flow diagram indicates that a certain amount of waste heat is available in the exhaust gas from the high-to-intermediate pressure gas turbine. Some of this energy can be used by applying expansion in a low-pressure turbine, optionally by applying regenerative water heating, which is then redirected to the combustion chamber, or finally by incorporating the ORC into the main cycle. For the ORC cycle, different configurations are studied, with regeneration and using different working fluids. For the highest efficiency of the cycle, the regenerative heating of high-pressure water is applied and a suitable ORC working fluid with optimal saturation parameters and mass flow is selected. Such modified proposed BECCS power plant hybrid systems with ORC are compared to the reference case with lower pressure expansion. A study of the heat duty and temperature distribution in heat exchangers is carried out. Five ORC fluids were investigated, namely ethanol, refrigerants R236ea, R245fa, R1233zd(E), and water, which gave a net efficiency of the whole power plant of 39.71%, 40.02%, 40.26%, 40.34%, and 39.35% respectively, while the proposed BECCS reference case gave 38.89%.

6 February 2025 in Energy
Verified
Journal Article
Closed access
Jakub MularskiJakub Mularski
Jakub Mularski
KSKamil Sylwester Stasiak
Kamil Sylwester Stasiak
MOMichał Ostrycharczyk
Michał Ostrycharczyk
MCMichał Czerep
Michał Czerep
MWMateusz Wnukowski
Mateusz Wnukowski
DMDariusz Mikielewicz
Dariusz Mikielewicz

3 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
JCJanusz Tadeusz Cieśliński
Janusz Tadeusz Cieśliński
JBJacek Barański
Jacek Barański
PDPaweł Dąbrowski
Paweł Dąbrowski
MFMaciej Fabrykiewicz
Maciej Fabrykiewicz
KSKamil Sylwester Stasiak
Kamil Sylwester Stasiak
KTKrzysztof TESCH
Krzysztof TESCH
This paper presents the results of calculations of the shell-side heat transfer coefficient and pressure drop for a shell-and-tube heat exchanger with an inner shell diameter of 200.2 mm and an effective tube length of 518 mm. The exchanger contained 85 copper tubes (12/10 mm), arranged in a staggered layout with a pitch ratio of 1.5. It was equipped with nine segmental baffles, with a 25% baffle cut and a baffle spacing of 48 mm. The inlet temperature of the hot water flowing through the shell, and the mass flow rate, were varied in the ranges of 35–79 °C and 1–3 kg/s, respectively. The calculations were performed using the extended Bell–Delaware method, the VDI (Gaddis–Gnielinski) method, and the Aspen Exchanger Design and Rating. CFD simulations were performed using the OpenFOAM and Ansys Fluent software packages. The calculated results were then compared with the available experimental data. The findings showed that the VDI method generated the greatest overestimation of the heat transfer coefficient and underestimated the pressure drop, whereas the extended Bell–Delaware method demonstrated the highest agreement with the experimental data.

9 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
JCJanusz Tadeusz Cieśliński
Janusz Tadeusz Cieśliński
KSKamil Sylwester Stasiak
Kamil Sylwester Stasiak
KTKrzysztof TESCH
Krzysztof TESCH
JBJacek Barański
Jacek Barański
PDPaweł Dąbrowski
Paweł Dąbrowski
This study presents the results of shell-side pressure drop calculations for a model shell-and-tube heat exchanger with an inner shell diameter of 200 mm and an effective tube length of 518 mm. The tube bundle consisted of 85 copper tubes (12/10 mm) arranged in a staggered layout with a pitch ratio of 1.5. The exchanger contained nine segmental baffles with a 25% cut, spaced 48 mm apart. The mean temperature of the hot water flowing on the shell side was 69 °C, and the mass flow rate varied in the range of 1–6 kg/s. In particular, the effects of the tube bundle diameter, nozzle diameter, and sealing strips on the pressure drop were investigated. The calculations employed the extended Bell–Delaware method and the VDI method. The results were compared with calculations performed using Aspen EDR and with numerical simulations carried out in OpenFOAM and Ansys Fluent. The comparison shows that the difference in total pressure drop estimation can reach up to 40% depending on the method used.

13 March 2026 in Energy
Verified
Journal Article
Closed access
CFChao Fu
Chao Fu
GSGonzalo del Alamo Serrano
Gonzalo del Alamo Serrano
PZPaweł Ziółkowski
Paweł Ziółkowski
KSKamil Sylwester Stasiak
Kamil Sylwester Stasiak
MKMaja Kaszuba
Maja Kaszuba
DMDariusz Mikielewicz
Dariusz Mikielewicz