Kanokwan Kiwfo

Dr. Kanokwan Kiwfo

Chiang Mai University, Chiang Mai, Thailand

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
KKKanokwan Kiwfo
Kanokwan Kiwfo
CYChonnipa Yeerum
Chonnipa Yeerum
Piyanat Issarangkura Na AyutthayaPiyanat Issarangkura Na Ayutthaya
Piyanat Issarangkura Na Ayutthaya
KKKullapon Kesonkan
Kullapon Kesonkan
SSSiripat Suteerapataranon
Siripat Suteerapataranon
Kate GrudpanKate Grudpan
Kate Grudpan
To minimize chemical waste and protect the environment, our team has used green analysis with natural reagents. In this work, we designed a natural-reagent assay kit for iron determination and implemented it in chemistry education in Thailand. The iron assay method was adapted from Thai local wisdom of testing water quality using guava leaves. The guava leaf powder served as a natural reagent in the assay. The kit included equipment, standard and buffer solutions and a manual. A smart device with a built-in camera was used as a detector. Educators in six universities in Thailand implemented the kit in laboratories with modifications depending on their learning outcomes. The kit implementation was evaluated using a survey with questions in four aspects: usability, learning achievement, green chemistry and portability. The high average scores for all questions (> 4.00 of 5.00 points), with the average overall score of 4.53 ± 0.60, indicated satisfaction regarding in all aspects. Using a locally available bio-resource as a natural reagent for green analysis in chemistry education supported sustainable education in Thailand, in terms of quality education (SDG 4) and reduced inequalities (SDG 10) and environmental sustainability (SDG 6—Clean water and sanitation, 12—Responsible consumption and production and 14—Life be-low water).

4 April 2020 in Molecules
Verified
Journal Article
Open access
PDF file
KKKanokwan Kiwfo
Kanokwan Kiwfo
WWWasin Wongwilai
Wasin Wongwilai
TSTadao Sakai
Tadao Sakai
NTNorio Teshiima
Norio Teshiima
Kate GrudpanKate Grudpan
Kate Grudpan
A mono-segmented sequential injection lab-at-valve (SI-LAV) system for the determination of albumin, glucose, and creatinine, three key biomarkers in diabetes screening and diagnosis, was developed as a single system for multi-analyte analysis. The mono-segmentation technique was employed for in-line dilution, in-line single-standard calibration, and in-line standard addition. This made adjustments to the sample preparation step easy unlike the batch-wise method. The results showed that the system could be used for both fast reaction (albumin) and slow reaction (glucose with enzymatic reaction and creatinine). In the case of slow reaction, the analysis time could be shortened by using the reaction rate obtained with the SI-LAV system. This proposed system is for cost-effective and downscaling analysis, which would be applicable for small hospitals and clinics in remote places with a small number of samples but relatively fast screening would be needed.

27 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
CYChonnipa Yeerum
Chonnipa Yeerum
Piyanat Issarangkura Na AyutthayaPiyanat Issarangkura Na Ayutthaya
Piyanat Issarangkura Na Ayutthaya
KKKullapon Kesonkan
Kullapon Kesonkan
KKKanokwan Kiwfo
Kanokwan Kiwfo
PBPloenpit Boochathum
Ploenpit Boochathum
MVMonnapat Vongboot
Monnapat Vongboot
A new biodegradable platform-based sensor for formaldehyde assay is proposed. Natural rubber latex was modified to polylactic acid–chloroacetated natural rubber polymer blend sheets. The polymer blend sheet was grafted using a water-based system with amine monomers as a platform, with a spot exhibiting positive polarity for immobilizing with anionic dye (Acid Red 27). The sensor was exposed to formaldehyde. The color intensity of the dye on the sensor spot would decrease. Using a smartphone with image processing (via ImageJ program), the color intensity change (∆B) could be followed. A linear calibration, ∆B intensity = 0.365 [FA] + 6.988, R2 = 0.997, was obtained for 10–150 mM FA with LOD and LOQ at 3 and 10 mM, respectively (linear regression method). The precision was lower than 20% RSD. Application to real seafood samples was demonstrated. The ready-to-use sensor with the proposed method was cost-effective, was portable for on-site analysis, and demonstrated green chemical analysis.

26 July 2021 in Plants
Verified
Journal Article
Open access
PDF file
SASutasinee Apichai
Sutasinee Apichai
CSChalermpong Saenjum
Chalermpong Saenjum
TPThanawat Pattananandecha
Thanawat Pattananandecha
KPKitti Phojuang
Kitti Phojuang
SWSiraprapa Wattanakul
Siraprapa Wattanakul
Kate GrudpanKate Grudpan
Kate Grudpan
A modern chemical sensor system (M-CSS) was developed for the cost-effective chemical analysis of Thai precision and sustainable agriculture (TPSA), which is suitable in rural Thailand and elsewhere. The aim of this study was to achieve precision and sustainable agriculture (P-SA). The M-CSS functions according to the International Union of Pure and Applied Chemistry (IUPAC) definition and incorporates information and communication technologies (ICTs). The developed chemical sensor in the M-CSS is based on a colorimetric determination by a smart device/smartphone. Additionally, the preparation of soil samples was investigated. Soil samples of optimal conditions were extracted using an acid extractant in the ratio of one to two (extract to soil sample). Then, phosphate-phosphorous and potassium were detected with the M-CSS, which showed an excellent correlation with the standard reference methods. Interestingly, it is noteworthy that the at-site analysis of the developed method could detect a greater nitrate-nitrogen content than that of the standard reference method. The developed cost-effective analysis for the plant macronutrient content in the soil, including nitrate-nitrogen, phosphate-phosphorous, and potassium, was demonstrated for organic vegetable farms at the real P-SA research site in Northern Thailand. The obtained results can guide the management of the application of fertilizers. The proposed M-CSS exhibited the potential to be used for at-site soil macronutrient analysis and represents the starting point of Thai precision and sustainable agriculture (TPSA).

7 October 2022 in Molecules
Verified
Journal Article
Open access
PDF file
CWChanyanut Wongsa
Chanyanut Wongsa
suruk udomsomsuruk udomsom
suruk udomsom
ABApiwat Budwong
Apiwat Budwong
KKKanokwan Kiwfo
Kanokwan Kiwfo
Kate GrudpanKate Grudpan
Kate Grudpan
PPPathinan Paengnakorn
Pathinan Paengnakorn
We proposed a specially designed sequential injection (SI) amperometric system coupling with a bioreactor for in-line glucose monitoring in cell culture. The system is composed of three main parts which are the bioreactor, SI system, and electrochemical detection unit. The bioreactor accommodates six individual cell culture units which can be operated separately under different conditions. The SI system enables automatic in-line sampling and in-line sample dilution, with a specially designed mixing unit; therefore, it has the benefits of fast analysis time and less contamination risk. The use of 3D-printed microfluidic components, a mixing channel, and a flow cell helped to reduce operational time and sample volume. A disposable screen-printed electrode (SPE), modified with glucose oxidase (GOD), carbon nanotube, and gold nanoparticle, was used for detection. The developed system provided a linear range up to 3.8 mM glucose in cell culture media. In order to work with cell culture in higher glucose media, the in-line sample dilution can be applied. The developed SI system was demonstrated with mouse fibroblast (L929) cell culture. The results show that glucose concentration obtained from the SI system is comparable with that obtained from the conventional colorimetric method. This work can be further developed and applied for in vitro cell-based experiments in biomedical research.
1

21 September 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Piyanat Issarangkura Na AyutthayaPiyanat Issarangkura Na Ayutthaya
Piyanat Issarangkura Na Ayutthaya
CYChonnipa Yeerum
Chonnipa Yeerum
KKKullapon Kesonkan
Kullapon Kesonkan
KKKanokwan Kiwfo
Kanokwan Kiwfo
Kate GrudpanKate Grudpan
Kate Grudpan
MVMonnapat Vongboot
Monnapat Vongboot
A monolithic rod of polyurethane foam–[4-(2-pyridylazo) resorcinol] (PUF–PAR) as a simple chemical sensor for lead assays with smartphone detection and image processing was developed. With readily available simple apparatus such as a plastic cup and a stirrer rod, the monolithic PUF rod was synthesized in a glass tube. The monolithic PUF–PAR rod could be directly loaded by standard/sample solution without sample preparation. A one-shot image in G/B value from a profile plot in ImageJ for a sample with triplicate results via a single standard calibration approach was obtained. A linear single standard calibration was: [G/B value] = −0.038[µg Pb2+] + 2.827, R2 = 0.95 for 10–30 µg Pb2+ with a limit of quantitation (LOQ) of 33 µg L−1. The precision was lower than 15% RSD. The proposed method was tested by an assay for Pb2+ contents in drinking water samples from Bangkok. The results obtained by the proposed method agree with those of ICP-OES and with 100–120% recovery, demonstrating that the method is useful for screening on-site water monitoring.