Telerehabilitation (TR) has gained attention as a promising rehabilitation format. Our study examined how patients responded to TR and whether it provided adequate support for their lifestyle changes and self-care efforts when compared to conventional rehabilitation (CR). Cardiac patients (n = 136) were randomly assigned to a TR or CR group. The TR group was provided with relevant health care technology for a period of three months, and both groups filled in questionnaires on their motivation for lifestyle changes and self-care psychological distress, and quality of life at 0, 3, 6, and 12 months. Patients in both groups were found to be equally motivated for lifestyle changes and self-care (p < 0.05) and they experienced similar levels of psychological distress and quality of life. TR is comparable to conventional rehabilitation in motivating patients, preventing psychological distress and improving quality of life. Although we observed an initial increase in autonomous motivation in the telerehabilitation group, this positive difference in motivation does not last over time. As such, neither rehabilitation format seems able to ensure long-term motivation. Therefore, TR may serve as a viable replacement for conventional rehabilitation when considered relevant. Further research is needed to enhance long-term motivation, and maybe telerehabilitation can help to achieve this.
30 August 2020 in Medical & Biological Engineering & Computing
Objective: Functional electrical stimulation (FES) is conventionally performed by the stimulation of motor axons causing the muscle fibers innervated by these axons to contract. An alternative strategy that may evoke contractions with more natural motor unit behavior is to stimulate afferent fibers (primarily type Ia) to excite the motor neurons at the spinal level. The aim of the study was to investigate the range of forces that can be evoked in this way and the degree to which the torque can be controlled. Methods: We stimulated the tibial nerve of ten healthy participants at amplitudes at which the highest H-reflex with minimal M-wave was present. The evoked plantar flexion torque was recorded following short stimulation pulses (0.4 ms) with frequencies ranging from 20 to 200 Hz. Results: Across all subjects, the median highest evocable torque was 38.3% (quartiles: 16.9-51.0) of the maximum voluntary contraction torque (MVC). The average torque variability (standard deviation) was 1.7 +/- 0.7% MVC. For most subjects, the relation between stimulation frequency and evoked torque was well characterized by sigmoidal curves (median root mean square error: 6.4% MVC). The plateau of this sigmoid curve (indicating the range of frequencies over which torque amplitude could be modulated) was reached at 56.0 (quartiles: 29.4-81.9) Hz. Conclusion: Using the proposed method for FES, substantial evoked torques that could be controlled by stimulation frequency were achieved. Significance: Stimulation of afferent fibers could be a useful and fatigue-resistant strategy for several applications of FES.
Objective. Human-computer interfaces (HCI) are potential tools for assisting (movement replacement) and rehabilitating (movement restoration) individuals with spinal cord injury (SCI). HCIs based on electroencephalography (EEG) have limited accuracy and hence control options; this could be improved by exploiting potential residual muscle activity (electromyography, EMG). The study objectives were to determine if combined EEG and EMG improves offline single-trial movement classification. Furthermore, the effect of number of classes and detection latency on the accuracies was investigated. Methods. Ten able-bodied and eight SCI subjects performed elbow flexion/extension at three force levels while EEG and EMG were recorded. Temporal and spectral features were extracted from the EEG and Hudgins time domain features were extracted from the EMG in 1-second time windows. The time window was shifted (200-ms shift) over 5second epochs around the movement onset. Each segment was classified in three scenarios (2, 3 or 7 classes) using linear discriminant analysis. Results. The accuracies obtained with EEG (51.2%) was outperformed by EMG (95.5%) and combined EMG and EEG (96.2%). Immediately after the EMG onset, the accuracies increased and rapidly reached a plateau. High accuracies were obtained for the different number of classes. Conclusion and Significance. EMG was crucial for obtaining high accuracies, and potential residual EMG should be exploited in HCIs to improve the performance. Force proved to be a viable option for SCI subjects with residual EMG to increase the number of classes for HCI control. These findings could assist design considerations of HCIs for SCI individuals.
For individuals with severe motor deficiencies, controlling external devices such as robotic arms or wheelchairs can be challenging, as many devices require some degree of motor control to be operated, e.g. when controlled using a joystick. A brain-computer interface (BCI) relies only on signals from the brain and may be used as a controller instead of muscles. Motor imagery (MI) has been used in many studies as a control signal for BCIs. However, MI may not be suitable for all control purposes, and several people cannot obtain BCI control with MI. In this study, the aim was to investigate the feasibility of decoding covert speech from single-trial EEG and compare and combine it with MI. In seven healthy subjects, EEG was recorded with twenty-five channels during six different actions: Speaking three words (both covert and overt speech), two arm movements (both motor imagery and execution), and one idle class. Temporal and spectral features were derived from the epochs and classified with a random forest classifier. The average classification accuracy was $67 \pm 9$ % and $75\pm 7$ % for covert and overt speech, respectively; this was 5–10 % lower than the movement classification. The performance of the combined movement-speech decoder was $61 \pm 9$ % and $67\pm 7$ % (covert and overt), but it is possible to have more classes available for control. The possibility of using covert speech for controlling a BCI was outlined; this is a step towards a multimodal BCI system for improved usability.
Although early rehabilitation is important following a stroke, severely affected patients have limited options for intensive rehabilitation as they are often bedridden. To create a system for early rehabilitation of lower extremities in these patients, we combined the robotic manipulator ROBERT® with electromyography (EMG)-triggered functional electrical stimulation (FES) and developed a novel user-driven Assist-As-Needed (AAN) control. The method is based on a state machine able to detect user movement capability, assessed by the presence of an EMG-trigger and the movement velocity, and provide different levels of assistance as required by the patient (no support, FES only, and simultaneous FES and mechanical assistance). To technically validate the system, we tested 10 able-bodied participants who were instructed to perform specific behaviors to test the system states while conducting knee extension and ankle dorsal flexion exercises. The system was also tested on two stroke patients to establish its clinical feasibility. The technical validation showed that the state machine correctly detected the participants' behavior and activated the target AAN state in more than 96% of the exercise repetitions. The clinical feasibility test showed that the system successfully recognized the patients' movement capacity and activated assistive states according to their needs providing the minimal level of support required to exercise successfully. The system was technically validated and preliminarily proved clinically feasible. The present study shows that the novel system can be used to deliver exercises with a high number of repetitions while engaging the participants' residual capabilities through the AAN strategy.