26 June 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Giovanni GugliandoloGiovanni Gugliandolo
Giovanni Gugliandolo
Laura ArruzzoliLaura Arruzzoli
Laura Arruzzoli
MLMariangela Catena Latino
Mariangela Catena Latino
Giovanni CrupiGiovanni Crupi
Giovanni Crupi
Nicola DonatoNicola Donato
Nicola Donato
This paper presents the design, fabrication, and characterization of a self-calibrating resonant sensor for the non-invasive dielectric characterization of materials. It is based on a ring resonator operating in the sub-gigahertz range and it exploits the mode-splitting phenomenon to perform differential measurements, wherein one resonance is sensible to the dielectric properties of a sample under test, while the orthogonal resonance serves as an internal reference. This strategy effectively mitigates common-mode perturbations, such as temperature drift. The prototype fabrication was carried out by inkjet-printing a conductive ink into a Rogers RO4003C substrate. The resulting prototype exhibits a nominal resonant frequency near 750 MHz. To characterize the sensor, several samples with known dielectric properties were placed on its surface, and the scattering parameters were measured over the 550-950 MHz frequency range. An analytical fitting procedure was employed to extract the central frequency, amplitude, and quality factor of each resonant peak in the magnitude of the forward transmission coefficient, and these parameters were observed to vary as a function of the samples dielectric properties. Additional tests demonstrated the sensor ability to reject common-mode disturbances. The promising results of these investigations are discussed in detail within the paper.

24 September 2025
Verified
Conference Paper
Closed access
Guido Di BellaGuido Di Bella
Guido Di Bella
Luigi CalabreseLuigi Calabrese
Luigi Calabrese
Laura ArruzzoliLaura Arruzzoli
Laura Arruzzoli
MLMariangela Catena Latino
Mariangela Catena Latino
Giovanni GugliandoloGiovanni Gugliandolo
Giovanni Gugliandolo
Nicola DonatoNicola Donato
Nicola Donato
The integration of structural and functional materials through additive manufacturing opens new perspectives for the development of smart components with embedded electronics. In this study, a novel multi-material and multi-process strategy is proposed to embed conductive circuits directly into 3D-printed PLA substrates. The workflow combines fused filament fabrication (FFF) with direct-write circuit printing. A conductive trace integrated within the PLA structure was fabricated and characterized, showing a resistance of (103.5 ± 0.1) Ω. The process also includes overprinting an additional PLA layer to encapsulate the circuit, enabling the creation of monolithic parts with embedded, protected conductive paths. This technique demonstrates the potential of integrating mechanical and electrical functionalities within a single, additively manufactured part.

1 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Laura ArruzzoliLaura Arruzzoli
Laura Arruzzoli
Giovanni GugliandoloGiovanni Gugliandolo
Giovanni Gugliandolo
EZEster Zirilli
Ester Zirilli
MLMariangela Catena Latino
Mariangela Catena Latino
Alessandro PistoneAlessandro Pistone
Alessandro Pistone
Nicola DonatoNicola Donato
Nicola Donato
This study addresses the inline dielectric characterization of liquids using a prototype planar resonant sensor with two capacitively coupled spirals, fabricated by inkjet printing on a Rogers RO4003C substrate. The device includes a central hole designed to host a sample vial or a pipe, enabling contactless characterization of liquid solutions, including biological samples. Experimental validation includes stylus profilometry and optical microscopy to verify the thickness, uniformity, and continuity of the conductive film, as well as scattering parameter measurements in the frequency range from 3.5 GHz to 4.0 GHz. The frequency response exhibits two distinct resonances; the corresponding resonance parameters for each mode (resonant frequency fr, amplitude, and quality factor Q) were extracted through complex-domain fitting using Lorentzian profiles. The electrical characterization of the device was assessed as a function of the effective permittivity of water–ethanol test mixtures by varying the ethanol volume fraction. The proposed sensor showed a monotonic and nearly linear response to ethanol concentration, with frequency sensitivities of approximately 20 kHz/% and coefficients of determination up to R2=0.99.

20 September 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Laura ArruzzoliLaura Arruzzoli
Laura Arruzzoli
CGCarmen Galletta
Carmen Galletta
Giovanni GugliandoloGiovanni Gugliandolo
Giovanni Gugliandolo
MLMariangela Catena Latino
Mariangela Catena Latino
Giovanni CrupiGiovanni Crupi
Giovanni Crupi
Nicola DonatoNicola Donato
Nicola Donato
Progressive neurodegenerative diseases are often associated with motor symptoms, among which tremor is one of the most debilitating manifestations, significantly compromising daily activities and quality of life. Continuous, non-invasive monitoring of tremor characteristics helps to assess disease progression and optimize treatment strategies. For this reason, wearable measurement systems can provide an objective and non-invasive means for the quantitative characterization and monitoring of tremor-related movements. This study addresses the development of a compact, low-power wearable board for real-time tremor monitoring based on the Nicla Sense ME embedded system. The proposed device performs on-board processing to extract spectral features of movement and wirelessly sends them via Bluetooth Low Energy to a remote host, enabling on-demand visualization or storage of tremor data. The measurement system was technically validated through a comparative experimental protocol based on the simultaneous acquisition of tremor signals using the proposed device and a commercial Shimmer3 IMU as the reference system. The comparison considered both the similarity of the measured spectrograms and the agreement in dominant-frequency estimation. Spectrogram correlation coefficients reached 0.85, with amplitude MAE and RMSE values as low as 0.07 m/s2 and 0.14 m/s2, respectively. For dominant-frequency estimation, Pearson correlation coefficients reached 0.99, with MAE and RMSE values as low as 0.17 Hz and 0.20 Hz. These results support the feasibility of the proposed architecture as a practical wearable solution for quantitative hand tremor monitoring.

22 October 2026 in Metrology
Verified
Journal Article
Open access
PDF file
Antonino QuattrocchiAntonino Quattrocchi
Antonino Quattrocchi
Giovanni GugliandoloGiovanni Gugliandolo
Giovanni Gugliandolo
GGGiada Garufi
Giada Garufi
Laura ArruzzoliLaura Arruzzoli
Laura Arruzzoli
FRFederico Randazzo
Federico Randazzo
Nicola DonatoNicola Donato
Nicola Donato
Handgrip strength is a widely used indicator of muscle function and it is particularly relevant for the functional assessment and rehabilitation of individuals with reduced grip capacity. This study presents the development, calibration, and short-term laboratory metrological characterization of a low-cost handgrip strength device (HGSD) manufactured by fused filament fabrication and integrating a force-sensing resistor (FSR). The device consists of two deformable half-shells designed to transfer the externally applied gripping force to an FSR integrated into a central mechanical interface. Two experimental campaigns were conducted under controlled laboratory conditions on a single HGSD assembly and its corresponding integrated FSR. The first characterized the isolated FSR under direct compression, whereas the second calibrated the complete HGSD using a dedicated mass-and-cable setup that reproduced the actions of the fingers and palm during a cylindrical grip. Increasing reference forces ranging from 0.70 kgf to 13.70 kgf (from 6.86 N to 134.35 N) were investigated. The isolated FSR exhibited a time-dependent decrease in its electrical resistance that was most pronounced at 2.45 kgf, where the mean relative variation was −2.53%. Short-term between-repetition coefficients of variation decreased from 0.59% at 2.45 kgf to 0.04% at 13.70 kgf. Power-law calibration models yielded resistance-domain goodness-of-fit metrics Rfit2= 0.923 and a mean squared error (RMSE) of 33.83 kΩ for the isolated FSR, compared with Rfit2= 0.994 and an RMSE of 12.22 kΩ for the complete HGSD. The different calibration exponents demonstrated that mechanical integration substantially modified the force-to-electrical resistance characteristic. An equivalent sensor-force response model was derived to quantify the overall electromechanical effect of integration. This relationship identifies the HGSD as a force-dependent nonlinear mechanical interface. Hence, the results quantitatively demonstrate that an isolated FSR calibration cannot be transferred directly to the assembled device and that the complete HGSD must be calibrated under representative mechanical integration and loading conditions. This study denotes the feasibility of the proposed measurement concept under controlled laboratory conditions but do not constitute a clinical validation.