Leonardo Göbel Fernandes

Mr. Leonardo Göbel Fernandes

Universidade Tecnológica Federal do Paraná - UTFPR, Curitiba, Paraná, Brazil
+2
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Leonardo Göbel FernandesLeonardo Göbel Fernandes
Leonardo Göbel Fernandes
Alceu André BadinAlceu André Badin
Alceu André Badin
DCDaniel Flores Cortez
Daniel Flores Cortez
RGRoger Gules
Roger Gules
EREduardo Félix Ribeiro Romaneli
Eduardo Félix Ribeiro Romaneli
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
A single-phase transformerless online uninterruptible power supply (UPS) is proposed in this paper. This UPS is based on the new half-bridge doubler-boost with switchedcapacitor operation. It is capable of operating with AC and DC input sources. The proposed converter provides a high power factor and improves power efficiency for line voltage applications. The switched capacitor concept allows a natural balance of the DC bus capacitor voltages, both in the AC-DC mode and in the DC-DC mode. It presents a common point between line voltage source, load, and batteries. This characteristic makes it possible to eliminate the common mode current, reducing problems with EMI and allowing the use of a simple bypass system. The feasibility of the proposed UPS is verified by experimental results from a 2.5 kW prototype with an efficiency of up to 94.9% and unity power factor.

1 November 2017
Verified
Conference Paper
Closed access
JMJulio C. S. de Morais
Julio C. S. de Morais
RGRoger Gules
Roger Gules
JMJuliano L. S. de Morais
Juliano L. S. de Morais
Leonardo Göbel FernandesLeonardo Göbel Fernandes
Leonardo Göbel Fernandes
In photovoltaic (PV) systems, high step-up dc-dc converters are required to manage the power flow. Since the output voltage of photovoltaic source is lower than the grid voltage level, dc-dc converters with high voltage gain are the solution in transformerless topologies. A high step-up dc-dc Ćuk converter with switched-inductor is proposed in this paper. The presented topology is designed to application in current source inverters (CSI) and unfolding inverters. Furthermore, to validate theoretical analysis, a 200W prototype is implemented. Lastly, a dc rectified sinusoidal output current modulation is performed to validate its application in unfolding inverters.

5 July 2023 in Data
Verified
Journal Article
Open access
PDF file
AGAndreas Anael Pereira Gomes
Andreas Anael Pereira Gomes
FGFrancisco Itamarati Secolo Ganacim
Francisco Itamarati Secolo Ganacim
FMFabiano Gustavo Silveira Magrin
Fabiano Gustavo Silveira Magrin
NBNara Bobko
Nara Bobko
Leonardo Göbel FernandesLeonardo Göbel Fernandes
Leonardo Göbel Fernandes
EREduardo Félix Ribeiro Romaneli
Eduardo Félix Ribeiro Romaneli
The lack of annotated semantic segmentation datasets for electrical substations in the literature poses a significant problem for machine learning tasks; before training a model, a dataset is needed. This paper presents a new dataset of electric substations with 1660 images annotated with 15 classes, including insulators, disconnect switches, transformers and other equipment commonly found in substation environments. The images were captured using a combination of human, fixed and AGV-mounted cameras at different times of the day, providing a diverse set of training and testing data for algorithm development. In total, 50,705 annotations were created by a team of experienced annotators, using a standardized process to ensure accuracy across the dataset. The resulting dataset provides a valuable resource for researchers and practitioners working in the fields of substation automation, substation monitoring and computer vision. Its availability has the potential to advance the state of the art in this important area.

11 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
RTRenan de Oliveira Alves Takeuchi
Renan de Oliveira Alves Takeuchi
LULeandra Ulbricht
Leandra Ulbricht
FMFabiano Gustavo Silveira Magrin
Fabiano Gustavo Silveira Magrin
FGFrancisco Itamarati Secolo Ganacim
Francisco Itamarati Secolo Ganacim
Leonardo Göbel FernandesLeonardo Göbel Fernandes
Leonardo Göbel Fernandes
JJJair Urbanetz Junior
Jair Urbanetz Junior
The variation in the thermal state of electrical energy substation equipment is normally associated with natural wear or equipment failure. This can be detected by infrared thermography, but technically it demands a long time to analyze these images. Computational analysis can allow an automated, more agile, and more efficient analysis to detect overheated regions in thermographic images. Therefore, it is necessary to segment the region of interest in the images; however, the results may diverge depending on the technique used. Thus, this article presents the improvement of four different techniques implemented in Python and applied in a substation under real operating conditions for a period of eleven months. The performance of the four methods was compared using eight statistical performance measures, and the efficiency was measured by the runtime. The segmentation results showed that the methods based on a threshold (Otsu and Histogram-Based Threshold) were fast, with processing times of 0.11 to 0.24 s, but caused excessive segmentation, presenting the lowest accuracy (0.160 and 0.444) and precision (0.004 and 0.049, respectively). The clustering-based methods (Cluster K-means and Fuzzy C-means) showed similar results to each other but were more accurate (0.936 to 1.000), more precise (0.965 to 1.000), and slower, with 2.55 and 38.8 s, respectively, compared to the threshold methods. The Fuzzy C-means method obtained the highest values of specificity, accuracy, and precision among the methods under analysis, followed by the Cluster K-means method.

27 November 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Leonardo Göbel FernandesLeonardo Göbel Fernandes
Leonardo Göbel Fernandes
JSJefferson Wilhelm Meyer Soares
Jefferson Wilhelm Meyer Soares
DCDaniel Flores Cortez
Daniel Flores Cortez
Alceu André BadinAlceu André Badin
Alceu André Badin
In industries, conventional multiphase interleaved boost converters are used to divide current stresses in semiconductors and increase the processed power. However, owing to the high sensibility of current division under variations in parasitic resistances and differences in duty cycles between phases, techniques are required to guarantee the division of input currents. This article proposes a multiphase interleaved boost converter with soft switching based on the switching cell with pulse-frequency modulation (SC-PFM) to solve this problem. This proposal presents a self-balance of the currents between the phases without a current control loop and soft switching. Moreover, the output diodes do not suffer from reverse recovery. The converter operates with only one output voltage control loop and one voltage sensor. The currents are naturally balanced owing to the input characteristics of the converter with low impact from differences between parasitic parameters of the modules. The experimental results of a 2-kW prototype with two modules of the interleaved boost converter (IBC)-SC-PFM validate the effectiveness of this solution with an efficiency of approximately 98%.

24 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
OJOsni Silva Junior
Osni Silva Junior
JCJose Carlos Pereira Coninck
Jose Carlos Pereira Coninck
FMFabiano Gustavo Silveira Magrin
Fabiano Gustavo Silveira Magrin
FGFrancisco Itamarati Secolo Ganacim
Francisco Itamarati Secolo Ganacim
APAnselmo Pombeiro
Anselmo Pombeiro
EREduardo Félix Ribeiro Romaneli
Eduardo Félix Ribeiro Romaneli
Infrared thermography is a predictive maintenance tool used in substations to identify a disturbance in electrical equipment that could lead to poor operation and potential failure in the future. According to Joule’s law, the temperature of electrical equipment is proportional to the current flowing through it. Other external factors, such as solar incidence, air humidity, wind speed, and air temperature, can interfere with its operating temperatures. Based on this premise, this article aims to analyze the influence of atmospheric and load conditions on the operational cycle of thermography-monitored equipment in order to describe the operating temperature of the object using only external data and to show the impacts of external influences on the final temperature reached by the object. Five multivariate time series regression models were developed to describe the maximum equipment temperature. The final model achieved the best fit between the measured and model temperature based on the Akaike information criterion (AIC) metric, where all external variables were used to compose the model. The proposed model shows the impacts of each external factor on equipment temperature and could be used to create a predictive maintenance strategy for power substations to avoid failure.