Louis W. Y. Liu

Dr. Louis W. Y. Liu

Faculty of Engineering, Vietnamese-German University, Ho Chi Minh City, Hồ Chí Minh, Vietnam
orcid
Research Interests: RF/microwave, Sensing, Radars, MEMS, ANN

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2017 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
AKAbhishek Kandwal
Abhishek Kandwal
QZQingfeng Zhang
Qingfeng Zhang
XTXiao-Lan Tang
Xiao-Lan Tang
Louis W. Y. LiuLouis W. Y. Liu
Louis W. Y. Liu
GZGe Zhang
Ge Zhang
This paper proposes a low-profile and highly efficient endfire radiating travelling-wave antenna based on spoof surface plasmon polaritons (SSPPs) transmission line. The aperture is approximately $0.32\lambda_{0}\times 0.01\lambda_{0}$ where $\lambda_{0}$ is the space wavelength at the operational frequency 8 GHz. This antenna generates near-endfire radiation beams within 7.5-8.5 GHz. The maximum gain and total efficiency reaches 9.2 dBi and 96%, respectively. Measurement results are finally given to validate the proposed SSPPs antenna.

5 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AKAbhishek Kandwal
Abhishek Kandwal
TITobore Igbe
Tobore Igbe
JLJingzhen Li
Jingzhen Li
YLYuhang Liu
Yuhang Liu
SLSinan Li
Sinan Li
NZNie Zedong
Nie Zedong
This paper presents a highly sensitive closed loop enclosed split ring biosensor operating in microwave frequencies for measuring blood glucose levels in the human body. The proposed microwave glucose biosensor, working on the principle of high field confinement and concentrated energy, has been tested using both in-vitro and in-vivo methods. This principle allows the sensor to concentrate energy at the surface which results in improved accuracy of measurements. For in-vitro measurements, the biosensor has been tested using de-ionized water glucose solutions of different concentrations. The miniaturized micrometer scale biosensor is fabricated over a thin Si-substrate using photolithographic technique. The biosensor has been designed in a way to operate at desired microwave frequencies. Highly confined fields and concentrated energy inside the closed loop line containing the split ring resonators are responsible for the sensitivity enhancement. This new biosensor has obtained a high sensitivity of 82 MHz/mgmL−1 within the clinical diabetic range during in-vivo testing over the human body. In addition, the subjects (undergoing experiments) steady state has been continuously monitored throughout the experiment which helps in improving the accuracy of the results. The proposed biosensor has further obtained a low detection limit of <0.05 wt.% and can be useful for continuous non-invasive blood glucose monitoring.

18 August 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AKAbhishek Kandwal
Abhishek Kandwal
NZNie Zedong
Nie Zedong
TITobore Igbe
Tobore Igbe
JLJingzhen Li
Jingzhen Li
YLYuhang Liu
Yuhang Liu
YHYang Hao
Yang Hao
This paper proposes a method of using a highly efficient spoof surface plasmon polariton (SSPP) endfire sensor for monitoring of aqueous glucose solutions and on-body glucose measurements. Occupying an area of around (52mm x 24mm), the proposed sensor radiates an endfire beam into a glucose water solution with a substantially reduced effective aperture. At the CPW port of the sensor, a pair of triangular ground planes was added to suppress the sidelobes, which have been proven to be counter-productive in glucose sensing. The slow wave nature of the proposed SSPP endfire sensor has further advantageously enabled the glucose concentrations to be measured with an increased sensitivity. The guiding body of the sensor was designed to simulate an electromagnetic beam propagating in a dense dielectric medium with a group velocity comparable to the phase velocity of light propagating in a glucose solution. Consistent with the results of our analysis, the experimental results of this work revealed that the gradual transition of slow electromagnetic wave from the SSPP endfire sensor to the glucose water solution has successfully enabled the glucose concentrations of a solution to be measured and displayed in the form of highly observable resonant frequency shifts in S11 parameters. The proposed design has achieved a high sensitivity of 150 MHz/mgmL-1 during onbody measurements.

25 October 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AKAbhishek Kandwal
Abhishek Kandwal
Louis W. Y. LiuLouis W. Y. Liu
Louis W. Y. Liu
Jamal DeenJamal Deen
Jamal Deen
RJRohit Jasrotia
Rohit Jasrotia
BKBinod Kumar Kanaujia
Binod Kumar Kanaujia
NZNie Zedong
Nie Zedong
Diabetes is one of the most persistent and common immedicable diseases characterized by elevated levels of blood glucose, rendering the early detection and diagnosis of diabetes utmost important. Irrespective of currently available invasive and minimally invasive techniques, the non-invasive glucose measurement has drawn lot of attentionon in present years, and continues to open up new areas for further research. This review provides a comprehensive overview of the developments over the last decade in the area of non-invasive blood glucose monitoring research, with particular reference given to the use of radio frequency electromagnetic wave (EM) for blood glucose sensing. The majority of the glucose sensors described in this paper have been proven to be reliable by Clarke Error Grid analysis or similar methods but, amid all other known challenges such as reproducibility, specificity and sensitivities, these glucose sensors were based on an expensive vector network analyzer (VNA). Finally, we conclude with a positive note that the non-invasive blood glucose monitoring research is beginning to be acknowledged not only on a global scale but also in applied physics and biomedical fields; however, more research is needed to overcome the challenges related to hardware alternative to a VNA and system integration involving enhancement of specificity and sensitivity.

12 June 2019 in Electronics
Verified
Journal Article
Open access
PDF file
Louis W. Y. LiuLouis W. Y. Liu
Louis W. Y. Liu
AKAbhishek Kandwal
Abhishek Kandwal
QCQingsha Cheng
Qingsha Cheng
HSHongjian Shi
Hongjian Shi
TITobore Igbe
Tobore Igbe
NZNie Zedong
Nie Zedong
Non-invasive blood glucose monitoring at microwave frequencies is generally thought to be unreliable in terms of reproducibility of measurements. The failure to reproduce a blood glucose measurement from one experiment to another is in major part due to the unwanted interaction of leaky waves between the ambient environment and the blood glucose measuring device. In this work, we have overcome this problem by simply eliminating the leaky modes through the use of surface electromagnetic waves from a curved Goubau line. In the proposed methodology, a fixed volume of blood-filled skin tissue was first formed by vacuum suction and partially wound with a curved Goubau line which was coated with a 3 mm thick layer of gelatin/glycerin composite. Blood glucose levels were non-invasively determined using a network analyzer. At 4.5 GHz, a near-linear correlation exists between the measured S12 parameters and the blood glucose levels. The measured correlation was highly reproducible and consistent with the measurements obtained using the conventional invasive lancing approach. The findings of this work suggest the feasibility of non-invasive detection of left and right imbalances in the body.

27 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Saeed RoshaniSaeed Roshani
Saeed Roshani
Salah I. YahyaSalah I. Yahya
Salah I. Yahya
BABan M. Alameri
Ban M. Alameri
YMYaqeen Sabah Mezaal
Yaqeen Sabah Mezaal
Louis W. Y. LiuLouis W. Y. Liu
Louis W. Y. Liu
SRSobhan Roshani
Sobhan Roshani
This paper proposes an ultra-compact filtering power divider with a wide harmonic suppression band. In this design, the proposed power divider (PD) in the ideal case has 100% size reduction and an infinite number of harmonics suppression. However, in the real case, the proposed divider has a 92% size reduction and suppresses the 2nd to 45th harmonics. The small-proposed divider is designed at 0.9 GHz. The typical Wilkinson divider has two long quarter-wavelength branches. In the proposed design, new resonant series LC branches are used instead of the divider’s typical branches, leading to performance improvements in the proposed PD. To the best of the authors’ knowledge, the proposed filtering PD has the best size reduction, and harmonics suppression reported thus far. The proposed divider has a filtering response with good insertion loss at the passband, which is desirable for modern communication systems.