Luca d'Agostino

Prof. Luca d'Agostino


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2014 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
Fu YanxiaFu Yanxia
Fu Yanxia
Jianping YuanJianping Yuan
Jianping Yuan
SYShouqi Yuan
Shouqi Yuan
GPGiovanni Pace
Giovanni Pace
LDLuca d'Agostino
Luca d'Agostino
XLXiaojun Li
Xiaojun Li
The characteristics of flow instabilities as well as the cavitation phenomenon in a centrifugal pump operating at low flow rates were studied by experimental and numerical means, respectively. Specially, a three-dimensional (3D) numerical model of cavitation was applied to simulate the internal flow through the pump and suitably long portions of the inlet and outlet ducts. As expected, cavitation proved to occur over a wide range of low flow rates, producing a characteristic creeping shape of the head-drop curve and developing in the form of nonaxisymmetric cavities. As expected, the occurrence of these cavities, attached to the blade suction sides, was found to depend on the pump's flow coefficient and cavitation number. The experiments focused on the flow visualization of the internal flow patterns by means of high-speed digital movies and in the analysis of the inlet pressure pulsations near the impeller eye by means of fast response pressure transducers. The experimental results showed that the unsteady behavior of the internal flow in the centrifugal pump operating at low flow rates has the characteristics of a peculiar low-frequency oscillation. Meanwhile, under certain conditions, the low-frequency pressure fluctuations were closely correlated to the flow instabilities induced by the occurrence of cavitation phenomena at low flow rates. Finally, the hydraulic performances of the centrifugal pump predicted by numerical simulations were in good agreement with the corresponding experimental data.

1 April 2015 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
GPGiovanni Pace
Giovanni Pace
DVDario Valentini
Dario Valentini
Angelo PasiniAngelo Pasini
Angelo Pasini
LTLucio Torre
Lucio Torre
Fu YanxiaFu Yanxia
Fu Yanxia
LDLuca d'Agostino
Luca d'Agostino
The paper presents the results of an activity carried out on a three-bladed inducer and compares the experimental data from other similar inducers. All the inducers considered in the present study have been designed by means of the simplified analytical model recently developed by some of the authors. The main effects of different geometrical solutions on hydraulic performance and flow instabilities of the pumps under noncavitating and cavitating conditions are presented in the paper.

1 November 2011 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
LTLucio Torre
Lucio Torre
Angelo CervoneAngelo Cervone
Angelo Cervone
Angelo PasiniAngelo Pasini
Angelo Pasini
LDLuca d'Agostino
Luca d'Agostino
The paper shows the results of an experimental campaign conducted in the CPRTF (Cavitating Pump Rotordynamic Test Facility) at ALTA S.p.A., aimed at characterizing the cavitation thermal effects on two tapered-hub, variable-pitch inducers, designated as DAPAMITO. The semiempirical method proposed by Ruggeri and Moore for scaling the thermal cavitation effects has been successfully applied and consequently, a further validation of this method has been provided. The influence of the temperature on the intensity of the performance degradation associated with the attached cavitation instability has been identified as a new typology of cavitation thermal effects. In this case, the inhibition of the bubble growth due to thermal effects can be detected by the reduction of the performance degradation usually associated with this type of instability.

23 September 2008 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
LDLuca d'Agostino
Luca d'Agostino
LTLucio Torre
Lucio Torre
Angelo PasiniAngelo Pasini
Angelo Pasini
Angelo CervoneAngelo Cervone
Angelo Cervone
A reduced order model for preliminary design and noncavitating performance prediction of tapered axial inducers is illustrated. In the incompressible, inviscid, irrotational flow approximation, the model expresses the 3D flow field in the blade channels by superposing a 2D cross-sectional vorticity correction to a fully guided axisymmetric flow with radially uniform axial velocity. Suitable redefinition of the diffusion factor for bladings with non-negligible radial flow allows for the control of the blade loading and the estimate of the boundary layer blockage at the specified design flow coefficient, providing a simple criterion for matching the hub profile to the axial variation of the blade pitch angle. Carter’s rule is employed to account for flow deviation at the inducer trailing edge. Mass continuity, angular momentum conservation, and Euler’s equation are used to derive a simple second order boundary value problem, whose numerical solution describes the far-field axisymmetric flow at the inducer discharge. A closed form approximate solution is also provided, which proved to yield equivalently accurate results in the prediction of the inducer performance. Finally, the noncavitating pumping characteristic is obtained by introducing suitably adapted correlations of pressure losses and flow deviation effects. The model has been verified to closely approximate the geometry and noncavitating performance of two space inducers tested in Alta’s Cavitating Pump Rotordynamic Test Facility, as well as the measured pumping characteristics of a number of tapered-hub inducers documented in the literature.

1 December 2011 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
Angelo PasiniAngelo Pasini
Angelo Pasini
LTLucio Torre
Lucio Torre
Angelo CervoneAngelo Cervone
Angelo Cervone
LDLuca d'Agostino
Luca d'Agostino
The paper illustrates the results of an experimental campaign conducted in the Cavitating Pump Rotordynamic Test Facility at ALTA S.p.A., aimed at characterizing the rotordynamic forces acting on a whirling four-bladed, tapered-hub, variable-pitch inducer, designated as DAPAMITO4. The roles of the imposed whirl motion of the rotor, flow coefficient, cavitation number and liquid temperature have been investigated. A novel experimental technique, consisting in measuring the continuous spectra of the forces as functions of the whirl ratio, has been developed and validated. This technique gives the possibility of extracting valuable information from the experiments by clearly identifying the qualitative and quantitative behavior of the forces, and is therefore useful to catch the unlikely foreseeable complexity of the rotordynamic forces and their consequences on the stability of axial inducers.

13 November 2018 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
GPGiovanni Pace
Giovanni Pace
DVDario Valentini
Dario Valentini
Angelo PasiniAngelo Pasini
Angelo Pasini
RHRuzbeh Hadavandi
Ruzbeh Hadavandi
LDLuca d'Agostino
Luca d'Agostino
The paper describes the results of recent experiments carried out in the Cavitating Pump Rotordynamic Test Facility for the dynamic characterization of cavitation-induced flow instabilities as simultaneously observed in the stationary and rotating frames of a high-head, three-bladed axial inducer with tapered hub and variable pitch. The flow instabilities occurring in the eye and inside the blading of the inducer have been detected, identified, and monitored by means of the spectral analysis of the pressure measurements simultaneously performed in the stationary and rotating frames by multiple transducers mounted on the casing near the inducer eye and on the inducer hub along the blade channels. An interaction between the unstable flows in the pump inlet and in the blade channels during cavitating regime has been detected. The interaction is between a low frequency axial phenomenon, which cyclically fills and empties each blade channel with cavitation, and a rotating phenomenon detected in the inducer eye.